Gossen Metrawatt 27I
Status planned
Source code gmc_mh_1x_2x
Counts 31000
IEC 61010-1 CAT II 600 V
Connectivity Infrared (RS232)
Measurements voltage, resistance, temperature, diode, continuity
Features autorange, data hold, backlight, insulation measurement, data logging
Website [1]

Please note: This page is a work in progress and still partly incorrect.

The Gossen Metrawatt Metrahit 27I is a 3100/31000 counts 600 V CAT II handheld digital multimeter with IR (RS232) connectivity. It supports milliohm and insulation (megaohm) measurements and has data logging capabilities.

Hardware

  • Power supply:
    • Battery: 3x 1,2 V NiMH rechargeable batteries
    • External power supply NA HIT 27 (Art. Z218J) by Gossen Metrawatt, 5V, 600 mA
  • Fuse:
    • FF (UR) 1,6 A/1000 V AC/DC (10 kA) 6,3 mm x 32 mm

Photos

Measurement functions and ranges

Measurement function Range Resolution Accuracy sigrok result Remarks
V= 3 V 100 μV ±(0,1% + 10) mq V, unit V, mqflags DC
30 V 1 mV ±(0,1% + 5) "
300 V 10 mV "
600 V 100 mV "
V≈ 3 V 100 μV ±(0,2% + 10) mq V, unit V, mqflags AC
30 V 1 mV "
300 V 10 mV "
600 V 100 mV "
mΩ@1A 3 mΩ 0.001 mΩ 1% + 10 mq Res., unit Ω, mqflags - 4-wire Kelvin measurement
30 mΩ 0.001 mΩ 0.5% + 10 " "
300 mΩ 0.01 mΩ " "
mΩ@200 mA 30 mΩ 0.01 mΩ 0.25% + 10 " "
300 mΩ 0.01 mΩ " "
3 Ω 0.1 mΩ " "
30 Ω 1 mΩ " "
Ω 300.00 Ω 1 mΩ 0.1% + 10 " ZERO with yellow button
3.0000 kΩ 10 mΩ 0,1% + 5 " "
30.000 kΩ 100 mΩ "
300.00 kΩ 1 Ω "
3.0000 MΩ 10 Ω "
30.000 MΩ 100 Ω 1.5% + 10 "
30 MΩ 10 kΩ 2% + 10 " Test voltage selectable 50/100/250/500 V
300 MΩ 100 kΩ " "
3 GΩ 1 MΩ 2% + 10 " "
Cont. 310 Ω 100 mΩ 1% + 5 mq Res., unit Ω, mqflags - Signal < about 10 Ω
Diode 3 V 100 µV 1% + 5 mq V, unit V, mqflags DC,DIODE
Hz 300.00 Hz 0.01 Hz ±(0.05% + 5) mq Freq., unit Hz, mqflags AC
3.000 kHz 0.1 Hz "
°C Pt100/Pt1000
–200.0 - +100.0 °C
0.1 °C ±(1 K + 5) mq Temp., unit °C, mqflags -
Pt100/Pt1000
+100.0 - 850.0 °C
±(0,5% + 5) "
NI 100/NI1000
-60-+180 °C
" Not tested yet due to lack of corresponding sensor.
°F " " " mq Temp., unit °F, mqflags - Details and ranges like °C.
Data Hold mqflags += HOLD Disabled while IR interface is active on  Matthias' test device.