Line 8: | Line 8: | ||
* 2 x Micron D9JLR DDR2 SDRAM 512M (32Mx16) | * 2 x Micron D9JLR DDR2 SDRAM 512M (32Mx16) | ||
* Xilinx Spartan XC3S400 | * Xilinx Spartan XC3S400 | ||
* Cypress CY7C68013A-56PVXC | * microchip LC24641 EEPROM for usb id | ||
* Cypress CY7C68013A-56PVXC (FX2) USB interface | |||
* Texas Instruments ADC08D500 High Performance, Low Power, Dual 8-Bit, 500 MSPS A/D Converter | * Texas Instruments ADC08D500 High Performance, Low Power, Dual 8-Bit, 500 MSPS A/D Converter | ||
* Analog Devices AD9742 12-Bit, 210 MSPS TxDAC® D/A Converter | * Analog Devices AD9742 12-Bit, 210 MSPS TxDAC® D/A Converter | ||
Line 14: | Line 15: | ||
* 3 x pca9557 | * 3 x pca9557 | ||
* 4 x omron g6h-2-100 | * 4 x omron g6h-2-100 | ||
* 3 x MEDER electronic SILO5-1A72-71DHR | |||
== More photos == | == More photos == |
Revision as of 23:26, 31 December 2012
The Pico Technology PicoScope 5203 is a 2-channel USB-based PC oscilloscope (and spectrum analyzer and data logger and logic analyzer). It supports a bandwidth of 250 MHz. The max. sampling rate (one-shot) is 1 GS/s (one channel mode) or 500 MS/s (two channel mode). The max. sampling rate for repetitive signals is 20 GS/s, the max. sampling rate in continuous streaming mode is 1 MS/s.
See Pico Technology PicoScope 5203/Info for more details (such as lsusb -vvv output) about the device.
Components
- 2 x Micron D9JLR DDR2 SDRAM 512M (32Mx16)
- Xilinx Spartan XC3S400
- microchip LC24641 EEPROM for usb id
- Cypress CY7C68013A-56PVXC (FX2) USB interface
- Texas Instruments ADC08D500 High Performance, Low Power, Dual 8-Bit, 500 MSPS A/D Converter
- Analog Devices AD9742 12-Bit, 210 MSPS TxDAC® D/A Converter
- Analog Devices ADCMP562 high speed comparator
- 3 x pca9557
- 4 x omron g6h-2-100
- 3 x MEDER electronic SILO5-1A72-71DHR
More photos
- Picoscope 5203 pcb front.jpg
PCB front
- Picoscope 5203 pcb back.jpg
PCB back
Protocol
Firmware
Start acquisition
Sample format
End acquisition
Triggers
Voltage ranges
±100 mV to ±20 V in 8 ranges