* '''Main chip''': MASTECH Japan M343-01 F0951D174 (80 pins, 16 + 16 + 24 + 24)
* '''Main chip''': MASTECH Japan M343-01 F0951D174 (80 pins, 16 + 16 + 24 + 24)
* '''14-stage binary counter/oscillator''': [http://datasheet.octopart.com/M74HC4060B1R-STMicroelectronics-datasheet-10836214.pdf ST 74HC4060 N00U732]
* '''14-stage binary counter/oscillator''': [http://datasheet.octopart.com/M74HC4060B1R-STMicroelectronics-datasheet-10836214.pdf ST 74HC4060 N00U732]
* '''?''': Texas Instruments 12AL9JM 0P07CP
* '''Precision Operational Amplifiers''': [http://www.ti.com/lit/ds/symlink/op07c.pdf Texas Instruments 12AL9JM 0P07CP]
* '''?''': GC7555AP AA7057HS
* '''?''': GC7555AP AA7057HS
* '''Opto Coupler''': [http://www.sharpsma.com/webfm_send/1092 Sharp B B5 PC817]
* '''Opto Coupler''': [http://www.sharpsma.com/webfm_send/1092 Sharp B B5 PC817]

Revision as of 14:29, 8 July 2012

MASTECH MAS345

The MASTECH MAS345 is a 3999 counts, CAT II handheld digital multimeter with RS232 connectivity.

It is also sold under the names Global Specialties Pro-70, Velleman DVM345DI, McVoice M-345pro, and Sinometer MAS345.

See MASTECH MAS345/Info for more details about the device.

Hardware

Multimeter:

RS232 cable:

  • TODO.

Photos

Protocol

The protocol is (partially) documented in the vendor software's "Help" window (seems to apply to MAS343, MAS344, and MAS345; the M9803R protocol is different).

  • Serial port settings: 600 baud, 7n2, RTS low, DTR high
  • Every time the host sends a (any?) character to the DMM (the vendor software sends D/0x44), it returns 14 ASCII bytes containing the measurement value and so on. The documentation states that a request interval of >= 1 second is "required for stable measuring data from meter".

Packet format:

Byte(s) Description
1-2 Measuring mode (DC, AC, OH, CA, TE, DI, ...)
3 Always a space (?)
4 Sign ('-' or ' ', i.e. a minus or a space)
5-9 Decimal point and current measurement value (Examples: 10.00, 0L, 3.999)
10-13 Unit (Examples: V, mV, A, mA, kOhm, MOhm, nF, ...)
14 Carriage return (13/0x0d)

Example packets:

01 02 03 04 05 06 07 08 09 10 11 12 13 14
D C - 0 0 0 . 0 V \r
A C 0 0 . 0 0 A \r
C A 0 . 0 7 1 n F \r
O H O . L M O h m \r

Resources