Difference between revisions of "Rigol DS4000 series"
Jump to navigation
Jump to search
(28 Mpts is per channel) |
|||
| Line 3: | Line 3: | ||
| status = supported | | status = supported | ||
| source_code_dir = | | source_code_dir = | ||
| channels = 2 or 4 | | channels = analog: 2 or 4, digital (MSO4000 series): 16 | ||
| samplerate = 4GSa/s (interleaved), 2GSa/s (non-interleaved) | | samplerate = analog: 4GSa/s (interleaved), 2GSa/s (non-interleaved); digital: 1GSa/s | ||
| bandwidth = 100-500MHz (depending on model) | | bandwidth = 100-500MHz (depending on model) | ||
| vertical_resolution = 8bits | | vertical_resolution = 8bits | ||
Revision as of 13:21, 29 December 2018
| Status | supported |
|---|---|
| Channels | analog: 2 or 4, digital (MSO4000 series): 16 |
| Samplerate | analog: 4GSa/s (interleaved), 2GSa/s (non-interleaved); digital: 1GSa/s |
| Analog bandwidth | 100-500MHz (depending on model) |
| Vertical resolution | 8bits |
| Triggers | edge, pulse, runt, nth edge, slope, video, pattern, RS232/UART, I²C, SPI, CAN, FlexRay, USB |
| Input impedance | 1MΩ‖15pF or 50Ω 300V RMS CAT I analog, 101kΩ‖9pF digital |
| Memory | 70/140 Mpts analog (mode/ch-dependent), 28 Mpts/channel (digital) |
| Display | 9 Inch WVGA (800x480) 160,000 colours |
| Connectivity | USB host/device, ethernet (LXI), aux out (trigger, fast, pass/fail, GND), VGA |
| Features | math: +, —, x, /, FFT, digital filters, editable advanced operations, logic; vertical sensitivity: 1 mV/div to 5 V/div |
| Website | rigolna.com |
The Rigol DS4000 Series are 4-channel oscilloscopes with an analog bandwidth of 100-500MHz and 4GSa/s maximum sampling rate.
Protocol
The device uses USBTMC or LXI via its Ethernet port for communication with a host PC. The protocol is based on SCPI commands.