Difference between revisions of "MHINSTEK UDB1xxxS"
(Add photos/resources) |
|||
Line 28: | Line 28: | ||
MHINSTEK_UDB1305S_detail_analog.jpg | MHINSTEK_UDB1305S_detail_analog.jpg | ||
</gallery> | </gallery> | ||
== Connection == | |||
All models communicate via an serial connection, at either 19200 or 57600 bps, 8 bits, no parity, and 1 stop bit (57600/8n1 or 19200/8n1). Connecting to the devices can be done with any USB-serial converter. Signalling level is 3.3V | |||
UDB1505S uses 57600 bps. | |||
== Protocol == | == Protocol == | ||
=== | The generator will respond to commands, which consist of a short ASCII string followed by CR (additional LFs are ignored). The meter will either send no response at all or some ASCII text followed by CR+LF. | ||
There a three classes of commands: | |||
# Identication | |||
# Set request | |||
# Get request | |||
Most set requests have a corresponding get request. | |||
=== Identification command === | |||
→ a | |||
← UDB1305S | |||
=== Set/get requests === | |||
==== Select channel A/B ==== | |||
→ bh1 | |||
← ok | |||
→ bh2 | |||
← ok | |||
Query (<code>ch</code>) always reports channel 0 (i.e. neither 1 or 2) | |||
==== Set/get frequency ==== | |||
5 MHz | |||
→ bf500000000 | |||
← ok | |||
→ cf | |||
← cf500000000 | |||
2 kHz | |||
→ bf000200000 | |||
← ok | |||
→ cf | |||
← cf000200000 | |||
1 Hz | |||
→ bf 100 | |||
← ok | |||
→ cf | |||
← cf000000100 | |||
== Resources == | == Resources == |
Revision as of 11:34, 15 November 2015
Status | planned |
---|---|
Frequency (user) | 0.01Hz-2MHz/5MHz/8MHz |
Waveforms | sine/square/triangle/sawtooth, TTL rect |
Amplitude | 10 V (adjustable) |
Connectivity | Serial TTL (5V) |
The UDB1302S/UDB1305S/UDB1308S is a Dual-Channel standalone function generator. It can be controlled with the push-buttons and the rotary encoder, or via a bidirectional serial interface.
Amplitude and offset voltage can only be controlled using potentiometers.
This device can be bought on ebay or aliexpress from various sellers for 40€/50€/60€.
Hardware
- CPLD: Altera MAXII
- Clock: 34.56MHz
Photos
Connection
All models communicate via an serial connection, at either 19200 or 57600 bps, 8 bits, no parity, and 1 stop bit (57600/8n1 or 19200/8n1). Connecting to the devices can be done with any USB-serial converter. Signalling level is 3.3V
UDB1505S uses 57600 bps.
Protocol
The generator will respond to commands, which consist of a short ASCII string followed by CR (additional LFs are ignored). The meter will either send no response at all or some ASCII text followed by CR+LF.
There a three classes of commands:
- Identication
- Set request
- Get request
Most set requests have a corresponding get request.
Identification command
→ a ← UDB1305S
Set/get requests
Select channel A/B
→ bh1 ← ok → bh2 ← ok
Query (ch
) always reports channel 0 (i.e. neither 1 or 2)
Set/get frequency
5 MHz → bf500000000 ← ok → cf ← cf500000000 2 kHz → bf000200000 ← ok → cf ← cf000200000 1 Hz → bf 100 ← ok → cf ← cf000000100