{{Infobox multimeter | {{Infobox multimeter | ||
| image = | | image = [[File:Gossen Metrawatt Metrahit 16I small.png|180px]] | ||
| name = Gossen Metrawatt Metrahit 16I | | name = Gossen Metrawatt Metrahit 16I | ||
| status = | | status = supported | ||
| source_code_dir = | | source_code_dir = gmc-mh-1x-2x | ||
| counts = 3100 (31000) | | counts = 3100 (31000) | ||
| categories = CAT III 1000 V, CAT IV 600 V | | categories = CAT III 1000 V, CAT IV 600 V | ||
Line 12: | Line 12: | ||
}} | }} | ||
The '''Gossen Metrawatt Metrahit 16I''' is a 3100 counts handheld digital multimeter with IR (RS232) connectivity and insulation measurement (500/1000 V). | The '''[[Gossen Metrawatt]] Metrahit 16I''' is a 3100 counts handheld digital multimeter with IR (RS232) connectivity and insulation measurement (500/1000 V). | ||
The resolution is one digit higher on the data interface. | The resolution is one digit higher on the data interface. | ||
== Hardware == | == Hardware == | ||
* '''Battery''': ''9 V IEC 6 LR 61'' | |||
* '''Fuse''': None! | * '''Fuse''': None! (not required, no internal amps ranges) | ||
* TODO. | * TODO. | ||
Line 24: | Line 24: | ||
== Photos == | == Photos == | ||
<gallery> | <gallery> | ||
File: | File:metrahit_16i_1.jpg|<small>Package</small> | ||
File: | File:metrahit_16i_2.jpg|<small>Inside</small> | ||
</gallery> | </gallery> | ||
--> | |||
== Measurement functions and ranges == | |||
{|border="0" style="font-size: smaller" class="alternategrey sortable sigroktable" | |||
|- | |||
! Measurement function | |||
! Range | |||
! Resolution | |||
! Deviation | |||
! sigrok result | |||
! Remarks | |||
|- | |||
| rowspan="6" | V= | |||
| 30 mV | |||
| 10 μV | |||
| ±(0.5% + 3) | |||
| mq V, unit V, mqflags DC | |||
| Input impendance >10 GΩ; not covered by autorange, use manual range | |||
|- | |||
| 300 mV | |||
| 100 μV | |||
| ±(0.5% + 3) | |||
| " | |||
| " | |||
|- | |||
| 3 V | |||
| 1 mV | |||
| rowspan="3" | ±(0.25% + 1) | |||
| " | |||
| | |||
|- | |||
| 30 V | |||
| 10 mV | |||
| " | |||
| | |||
|- | |||
| 300 V | |||
| 100 mV | |||
| " | |||
| | |||
|- | |||
| 600 V | |||
| 1 V | |||
| ±(0.35% + 1) | |||
| " | |||
| | |||
|- | |||
| rowspan="4" | V≈ | |||
| 3 V | |||
| 100 μV | |||
| rowspan="4" | ±(1.0% + 3) (> 10 Digit) | |||
| mq V, unit V, mqflags AC,RMS | |||
| | |||
|- | |||
| 30 V | |||
| 100 μV | |||
| " | |||
| | |||
|- | |||
| 300 V | |||
| 1 mV | |||
| " | |||
| | |||
|- | |||
| 1000 V | |||
| 10 mV | |||
| " | |||
| | |||
|- | |||
| rowspan="4" | V≃ | |||
| 3 V | |||
| 100 μV | |||
| rowspan="4" | ±(1.0% + 3) (> 10 Digit) | |||
| mq V, unit V, mqflags AC,DC,RMS | |||
| | |||
|- | |||
| 30 V | |||
| 100 μV | |||
| " | |||
| | |||
|- | |||
| 300 V | |||
| 1 mV | |||
| " | |||
| | |||
|- | |||
| 1000 V | |||
| 10 mV | |||
| " | |||
| | |||
|- | |||
| rowspan="2" | A≈ (Clamp only) | |||
| 30 A | |||
| 10 mA | |||
| rowspan="2" | ±(2.5% + 3) (>10 Digit) | |||
| mq Curr., unit A, mqflags AC,DC,RMS | |||
| rowspan="2" | Current clamp with 100 mV/A required, e.g. GMC WZ12B | |||
|- | |||
| 100 A | |||
| 100 mA | |||
| " | |||
|- | |||
| rowspan="7" | Ω | |||
| 30.00 Ω | |||
| 10 mΩ | |||
| rowspan="2" | ±(0.5% + 3) | |||
| mq Res., unit Ω, mqflags - | |||
| | |||
|- | |||
| 300.0 Ω | |||
| 100 mΩ | |||
| " | |||
| | |||
|- | |||
| 3.000 kΩ | |||
| 1 Ω | |||
| rowspan="3" | ±(0.4% + 1) | |||
| " | |||
| | |||
|- | |||
| 30.00 kΩ | |||
| 10 Ω | |||
| " | |||
| | |||
|- | |||
| 300.0 kΩ | |||
| 100 Ω | |||
| " | |||
| | |||
|- | |||
| 3.000 MΩ | |||
| 1 kΩ | |||
| ±(0.6% + 1) | |||
| " | |||
| | |||
|- | |||
| 30.00 MΩ | |||
| 10 kΩ | |||
| ±(2.0% + 1) | |||
| " | |||
| | |||
|- | |||
| Ω Iso 500V | |||
| 1.600 GΩ | |||
| 1 kΩ - 1 MΩ | |||
| rowspan="2" | ±(3% + 2) | |||
| mq Res., unit Ω, mqflags - | |||
| Altogether 4 ranges with different resolution | |||
|- | |||
| Ω Iso 1000V | |||
| 3.100 GΩ | |||
| 1 kΩ - 1 MΩ | |||
| mq Res., unit Ω, mqflags - | |||
| Altogether 4 ranges with different resolution | |||
|- | |||
| Diode/Cont. | |||
| 3.000 V– | |||
| 1 mV | |||
| ±(0.25% + 1) | |||
| mq V, unit V, mqflags DC,DIODE | |||
| Diode and cont. are identical on this device, just without beeper for diode. | |||
|- | |||
| rowspan="4" | Cap. F | |||
| 30.00 nF | |||
| 10 pF | |||
| rowspan="3" | ±(1.0% + 3) | |||
| mq Cap., unit F, mqflags - | |||
| | |||
|- | |||
| 300.0 nF | |||
| 100 pF | |||
| " | |||
| | |||
|- | |||
| 3.000 µF | |||
| 1 nF | |||
| " | |||
| | |||
|- | |||
| 30.00 µF | |||
| 10 nF | |||
| ±(3.0% + 3) | |||
| " | |||
| | |||
|- | |||
| rowspan="4" | Hz= | |||
| 300.0 Hz | |||
| 0.01 Hz | |||
| rowspan="4" | ±(0.1% + 3) | |||
| mq Freq., unit Hz | |||
| The protocol does not allow to differ AC and DC. | |||
|- | |||
| 3.000 kHz | |||
| 0.1 Hz | |||
| " | |||
| | |||
|- | |||
| 30.00 kHz | |||
| 1 Hz | |||
| " | |||
| | |||
|- | |||
| 100.00 kHz | |||
| 10 Hz | |||
| " | |||
| | |||
|- | |||
| rowspan="4" | Hz≈ | |||
| 300.0 Hz | |||
| 0.01 Hz | |||
| rowspan="4" | ±(0.1% + 3) | |||
| mq Freq., unit Hz | |||
| The protocol does not allow to differ AC and DC. | |||
|- | |||
| 3.000 kHz | |||
| 0.1 Hz | |||
| " | |||
| | |||
|- | |||
| 30.00 kHz | |||
| 1 Hz | |||
| " | |||
| | |||
|- | |||
| 100.00 kHz | |||
| 10 Hz | |||
| " | |||
| | |||
|- | |||
| rowspan="4" | °C | |||
| Pt100 –200.0 - +200.0 °C | |||
| rowspan="4" | 0.1 °C | |||
| 2 Kelvin + 5 | |||
| mq Temp., unit °C, mqflags - | |||
| | |||
|- | |||
| Pt100 +200.0 - +800.0 °C | |||
| ±(1.0% + 5) | |||
| " | |||
| | |||
|- | |||
| Pt1000 –100.0 - +200.0 °C | |||
| 2 Kelvin + 5 | |||
| " | |||
| | |||
|- | |||
| Pt1000 +200.0 - +800.0 °C | |||
| ±(1.0% + 5) | |||
| " | |||
| | |||
|- | |||
| Event count | |||
| | |||
| | |||
| | |||
| style="background: #ffff00; "| | |||
| Seems not to be present on data output. | |||
|- | |||
| Data Hold | |||
| | |||
| | |||
| | |||
| style="background: #ff0000; "| mqflags += HOLD | |||
| Disabled while IR interface is active on [[User:Matthias Heidbrink | Matthias']] device. | |||
|- | |||
| MIN | |||
| | |||
| | |||
| | |||
| style="background: #ff0000; "| mqflags += MIN | |||
| Influences only display, via IR flag is set, but actual current value is delivered. | |||
|- | |||
| MAX | |||
| | |||
| | |||
| | |||
| style="background: #ff0000; "| mqflags += MAX | |||
| Influences only display, via IR flag is set, but actual current value is delivered. | |||
|- | |||
|} | |||
The column "sigrok result" contains in short form what the driver generates for the resp. data type. | |||
[[Category:Device]] | [[Category:Device]] | ||
[[Category:Multimeter]] | [[Category:Multimeter]] | ||
[[Category: | [[Category:Supported]] |
Latest revision as of 20:33, 21 September 2016
Status | supported |
---|---|
Source code | gmc-mh-1x-2x |
Counts | 3100 (31000) |
IEC 61010-1 | CAT III 1000 V, CAT IV 600 V |
Connectivity | Infrared (RS232) |
Measurements | voltage, current, resistance, capacitance, temperature, diode, continuity |
Features | autorange, data hold, bargraph |
Website | [1] |
The Gossen Metrawatt Metrahit 16I is a 3100 counts handheld digital multimeter with IR (RS232) connectivity and insulation measurement (500/1000 V).
The resolution is one digit higher on the data interface.
Hardware
- Battery: 9 V IEC 6 LR 61
- Fuse: None! (not required, no internal amps ranges)
- TODO.
Photos
Measurement functions and ranges
Measurement function | Range | Resolution | Deviation | sigrok result | Remarks |
---|---|---|---|---|---|
V= | 30 mV | 10 μV | ±(0.5% + 3) | mq V, unit V, mqflags DC | Input impendance >10 GΩ; not covered by autorange, use manual range |
300 mV | 100 μV | ±(0.5% + 3) | " | " | |
3 V | 1 mV | ±(0.25% + 1) | " | ||
30 V | 10 mV | " | |||
300 V | 100 mV | " | |||
600 V | 1 V | ±(0.35% + 1) | " | ||
V≈ | 3 V | 100 μV | ±(1.0% + 3) (> 10 Digit) | mq V, unit V, mqflags AC,RMS | |
30 V | 100 μV | " | |||
300 V | 1 mV | " | |||
1000 V | 10 mV | " | |||
V≃ | 3 V | 100 μV | ±(1.0% + 3) (> 10 Digit) | mq V, unit V, mqflags AC,DC,RMS | |
30 V | 100 μV | " | |||
300 V | 1 mV | " | |||
1000 V | 10 mV | " | |||
A≈ (Clamp only) | 30 A | 10 mA | ±(2.5% + 3) (>10 Digit) | mq Curr., unit A, mqflags AC,DC,RMS | Current clamp with 100 mV/A required, e.g. GMC WZ12B |
100 A | 100 mA | " | |||
Ω | 30.00 Ω | 10 mΩ | ±(0.5% + 3) | mq Res., unit Ω, mqflags - | |
300.0 Ω | 100 mΩ | " | |||
3.000 kΩ | 1 Ω | ±(0.4% + 1) | " | ||
30.00 kΩ | 10 Ω | " | |||
300.0 kΩ | 100 Ω | " | |||
3.000 MΩ | 1 kΩ | ±(0.6% + 1) | " | ||
30.00 MΩ | 10 kΩ | ±(2.0% + 1) | " | ||
Ω Iso 500V | 1.600 GΩ | 1 kΩ - 1 MΩ | ±(3% + 2) | mq Res., unit Ω, mqflags - | Altogether 4 ranges with different resolution |
Ω Iso 1000V | 3.100 GΩ | 1 kΩ - 1 MΩ | mq Res., unit Ω, mqflags - | Altogether 4 ranges with different resolution | |
Diode/Cont. | 3.000 V– | 1 mV | ±(0.25% + 1) | mq V, unit V, mqflags DC,DIODE | Diode and cont. are identical on this device, just without beeper for diode. |
Cap. F | 30.00 nF | 10 pF | ±(1.0% + 3) | mq Cap., unit F, mqflags - | |
300.0 nF | 100 pF | " | |||
3.000 µF | 1 nF | " | |||
30.00 µF | 10 nF | ±(3.0% + 3) | " | ||
Hz= | 300.0 Hz | 0.01 Hz | ±(0.1% + 3) | mq Freq., unit Hz | The protocol does not allow to differ AC and DC. |
3.000 kHz | 0.1 Hz | " | |||
30.00 kHz | 1 Hz | " | |||
100.00 kHz | 10 Hz | " | |||
Hz≈ | 300.0 Hz | 0.01 Hz | ±(0.1% + 3) | mq Freq., unit Hz | The protocol does not allow to differ AC and DC. |
3.000 kHz | 0.1 Hz | " | |||
30.00 kHz | 1 Hz | " | |||
100.00 kHz | 10 Hz | " | |||
°C | Pt100 –200.0 - +200.0 °C | 0.1 °C | 2 Kelvin + 5 | mq Temp., unit °C, mqflags - | |
Pt100 +200.0 - +800.0 °C | ±(1.0% + 5) | " | |||
Pt1000 –100.0 - +200.0 °C | 2 Kelvin + 5 | " | |||
Pt1000 +200.0 - +800.0 °C | ±(1.0% + 5) | " | |||
Event count | Seems not to be present on data output. | ||||
Data Hold | mqflags += HOLD | Disabled while IR interface is active on Matthias' device. | |||
MIN | mqflags += MIN | Influences only display, via IR flag is set, but actual current value is delivered. | |||
MAX | mqflags += MAX | Influences only display, via IR flag is set, but actual current value is delivered. |
The column "sigrok result" contains in short form what the driver generates for the resp. data type.