Difference between revisions of "Metex ME-21"
Jump to navigation
Jump to search
(Add Metex ME-21 DMM) |
m (Added some details) |
||
(One intermediate revision by the same user not shown) | |||
Line 7: | Line 7: | ||
| categories = CAT II (1000V) | | categories = CAT II (1000V) | ||
| connectivity = RS232 | | connectivity = RS232 | ||
| measurements = voltage, resistance, continuity, diode, current, frequency | | measurements = voltage, resistance, continuity, diode, current, frequency, logic | ||
| features = hold, | | features = bargraph, data hold, Min/Max | ||
| website = [https://www.tequipment.net/MetexME-21.html tequipment.net] | | website = [https://www.tequipment.net/MetexME-21.html tequipment.net] | ||
}} | }} | ||
Line 17: | Line 17: | ||
TODO. | TODO. | ||
UM7106 3 1⁄2 Digit A/D Converter | |||
Isolated RS232 Port, needs "active" USB RS232 Adapter or native RS232 Port. | |||
== Photos == | == Photos == | ||
Line 22: | Line 26: | ||
'''Multimeter''': | '''Multimeter''': | ||
<gallery> | |||
File:Metex_ME-21_Port.jpg|<small>RS232 Port</small> | |||
File:Metex_ME-21_PCB_Top.jpg|<small>PCB Top</small> | |||
File:Metex_ME-21_PCB_Bottom.jpg|<small>PCB Bottom</small> | |||
File:Metex_ME-21_Controller.jpg|<small>PCB Controller</small> | |||
</gallery> | |||
== Protocol == | == Protocol == |
Latest revision as of 21:49, 26 May 2020
Status | supported |
---|---|
Source code | serial-dmm |
Counts | 2000 |
IEC 61010-1 | CAT II (1000V) |
Connectivity | RS232 |
Measurements | voltage, resistance, continuity, diode, current, frequency, logic |
Features | bargraph, data hold, Min/Max |
Website | tequipment.net |
The Metex ME-21 is a 2000 counts, CAT II (1000V) handheld digital multimeter with RS232 connectivity.
Hardware
TODO.
UM7106 3 1⁄2 Digit A/D Converter
Isolated RS232 Port, needs "active" USB RS232 Adapter or native RS232 Port.
Photos
Multimeter:
Protocol
See Multimeter_ICs#Metex_14-byte_ASCII for the DMM IC protocol.
Resources
TODO.