Difference between revisions of "MHINSTEK UDB1xxxS"
(One intermediate revision by the same user not shown) | |||
Line 6: | Line 6: | ||
| frequser = 0.01Hz-2MHz/5MHz/8MHz | | frequser = 0.01Hz-2MHz/5MHz/8MHz | ||
| waveforms = sine/square/triangle/sawtooth, TTL rect | | waveforms = sine/square/triangle/sawtooth, TTL rect | ||
| amplitude = 10 V (adjustable) | | amplitude = 10 V (open)/5 V (50 Ohm) (adjustable) | ||
| connectivity = Serial TTL ( | | connectivity = Serial TTL (3.3V) | ||
}} | }} | ||
Line 20: | Line 20: | ||
* CPLD: Altera MAXII | * CPLD: Altera MAXII | ||
* Clock: 34.56MHz | * Clock: 34.56MHz | ||
* STM8S105K4 8-bit MCU with 16 Kbytes Flash, 16 MHz CPU, integrated EEPROM [http://www.st.com/web/catalog/mmc/FM141/SC1244/SS1010/LN754/PF215111 STM8S10K54 procuct page] | |||
* 74AHC14 Hex inverting Schmitt trigger (TTL output buffer, Freq/counter input buffer) | |||
== Photos == | == Photos == |
Latest revision as of 16:56, 15 November 2015
Status | planned |
---|---|
Frequency (user) | 0.01Hz-2MHz/5MHz/8MHz |
Waveforms | sine/square/triangle/sawtooth, TTL rect |
Amplitude | 10 V (open)/5 V (50 Ohm) (adjustable) |
Connectivity | Serial TTL (3.3V) |
The UDB1302S/UDB1305S/UDB1308S is a Dual-Channel standalone function generator. It can be controlled with the push-buttons and the rotary encoder, or via a bidirectional serial interface.
Amplitude and offset voltage can only be controlled using potentiometers.
This device can be bought on ebay or aliexpress from various sellers for 40€/50€/60€.
Hardware
- CPLD: Altera MAXII
- Clock: 34.56MHz
- STM8S105K4 8-bit MCU with 16 Kbytes Flash, 16 MHz CPU, integrated EEPROM STM8S10K54 procuct page
- 74AHC14 Hex inverting Schmitt trigger (TTL output buffer, Freq/counter input buffer)
Photos
Connection
All models communicate via an serial connection, at either 19200 or 57600 bps, 8 bits, no parity, and 1 stop bit (57600/8n1 or 19200/8n1). Connecting to the devices can be done with any USB-serial converter. Signalling level is 3.3V
UDB1505S uses 57600 bps.
Protocol
The generator will respond to commands, which consist of a short ASCII string followed by CR (additional LFs are ignored). The meter will either send no response at all or some ASCII text followed by CR+LF.
There a three classes of commands:
- Identication
- Set request
- Get request
Most set requests have a corresponding get request.
Identification command
→ a ← UDB1305S
Set/get requests
Select channel A/B
→ bh1 ← ok → bh2 ← ok
Query (ch
) always reports channel 0 (i.e. neither 1 or 2)
Set/get frequency
5 MHz → bf500000000 ← ok → cf ← cf500000000 2 kHz → bf000200000 ← ok → cf ← cf000200000 1 Hz → bf 100 ← ok → cf ← cf000000100