Difference between revisions of "Gossen Metrawatt Metrahit 14S"
Jump to navigation
Jump to search
m (Fixed driver path.) |
m (→Measurement functions and ranges: Cosmetics.) |
||
(One intermediate revision by the same user not shown) | |||
Line 2: | Line 2: | ||
| image = <!-- [[File:Gossen Metrawatt Metrahit 18S small.png|180px]] --> | | image = <!-- [[File:Gossen Metrawatt Metrahit 18S small.png|180px]] --> | ||
| name = [[Gossen Metrawatt]] Metrahit 14S | | name = [[Gossen Metrawatt]] Metrahit 14S | ||
| status = | | status = in progress | ||
| source_code_dir = gmc-mh-1x-2x | | source_code_dir = gmc-mh-1x-2x | ||
| counts = 3100 | | counts = 3100 | ||
Line 57: | Line 57: | ||
| 30.00 mV | | 30.00 mV | ||
| 10 μV | | 10 μV | ||
| rowspan="2" | ±(0 | | rowspan="2" | ±(0.5% + 3) | ||
| mq V, unit V, mqflags DC | | mq V, unit V, mqflags DC | ||
| | | | ||
Line 70: | Line 70: | ||
| 3.000 V | | 3.000 V | ||
| 1 mV | | 1 mV | ||
| rowspan="3" | ±(0 | | rowspan="3" | ±(0.25% + 1) | ||
| " | | " | ||
| | | | ||
Line 89: | Line 89: | ||
| 1000 V | | 1000 V | ||
| 1 V | | 1 V | ||
| ±(0 | | ±(0.35% + 1) | ||
| " | | " | ||
| | | | ||
Line 97: | Line 97: | ||
| 3.000 V | | 3.000 V | ||
| 100 μV | | 100 μV | ||
| rowspan="4" | ±(0 | | rowspan="4" | ±(0.75% + 2) | ||
| " | | " | ||
| | | | ||
Line 123: | Line 123: | ||
| 300.0 µA | | 300.0 µA | ||
| 100 nA | | 100 nA | ||
| ±(1 | | ±(1.0% + 5) | ||
| mq Curr., unit A, mqflags DC | | mq Curr., unit A, mqflags DC | ||
| Disabled on power on, see below. | | Disabled on power on, see below. | ||
Line 130: | Line 130: | ||
| 3.000 mA | | 3.000 mA | ||
| 1 µA | | 1 µA | ||
| ±(1 | | ±(1.0 + 2) | ||
| " | | " | ||
| Disabled on power on, see below. | | Disabled on power on, see below. | ||
Line 137: | Line 137: | ||
| 30.00 mA | | 30.00 mA | ||
| 10 µA | | 10 µA | ||
| ±(1 | | ±(1.0% + 5) | ||
| " | | " | ||
| | | | ||
Line 144: | Line 144: | ||
| 300.0 mA | | 300.0 mA | ||
| 100 µA | | 100 µA | ||
| ±(1 | | ±(1.0% + 2) | ||
| " | | " | ||
| | | | ||
Line 151: | Line 151: | ||
| 3.000 A | | 3.000 A | ||
| 1 mA | | 1 mA | ||
| ±(1 | | ±(1.0% + 5) | ||
| " | | " | ||
| Disabled on power on, see below. | | Disabled on power on, see below. | ||
Line 158: | Line 158: | ||
| 10.00 A | | 10.00 A | ||
| 10 mA | | 10 mA | ||
| ±(1 | | ±(1.0% + 2) | ||
| " | | " | ||
| | | | ||
Line 166: | Line 166: | ||
| 3.000 mA | | 3.000 mA | ||
| 1 µA | | 1 µA | ||
| rowspan="3" | ±(1 | | rowspan="3" | ±(1.5% + 2) | ||
| mq Curr., unit A, mqflags AC,DC,RMS | | mq Curr., unit A, mqflags AC,DC,RMS | ||
| | | | ||
Line 295: | Line 295: | ||
The column "sigrok result" contains in short form what the driver generates for the resp. data type. | The column "sigrok result" contains in short form what the driver generates for the resp. data type. | ||
[[Category:Device]] | [[Category:Device]] | ||
[[Category:Multimeter]] | [[Category:Multimeter]] | ||
[[Category:Planned]] | [[Category:Planned]] |
Latest revision as of 20:31, 21 September 2016
Status | in progress |
---|---|
Source code | gmc-mh-1x-2x |
Counts | 3100 |
IEC 61010-1 | CAT III 1000 V, CAT IV 600 V |
Connectivity | Infrared (RS232) |
Measurements | voltage, current, resistance, capacitance, temperature, diode, continuity |
Features | autorange, data hold, bargraph |
The Gossen Metrawatt Metrahit 14S is a 3100 counts handheld digital multimeter with IR (RS232) connectivity.
It is expected to work with the driver gmc-mh-1x-2x-rs232, but unsupported due to lack of a test device.
This page is a work in progress, information incomplete and possibly inaccurate!
Measurement functions and ranges
Measurement function | Range | Resolution | Accuracy | sigrok result | Remarks |
---|---|---|---|---|---|
V= | 30.00 mV | 10 μV | ±(0.5% + 3) | mq V, unit V, mqflags DC | |
300.0 mV | 100 μV | " | |||
3.000 V | 1 mV | ±(0.25% + 1) | " | ||
30.00 V | 10 mV | " | |||
300.0 V | 100 mV | " | |||
1000 V | 1 V | ±(0.35% + 1) | " | ||
V≈ | 3.000 V | 100 μV | ±(0.75% + 2) | " | |
30.00 V | 100 μV | " | |||
300.0 V | 1 mV | " | |||
1000 V | 10 mV | " | |||
A= | 300.0 µA | 100 nA | ±(1.0% + 5) | mq Curr., unit A, mqflags DC | Disabled on power on, see below. |
3.000 mA | 1 µA | ±(1.0 + 2) | " | Disabled on power on, see below. | |
30.00 mA | 10 µA | ±(1.0% + 5) | " | ||
300.0 mA | 100 µA | ±(1.0% + 2) | " | ||
3.000 A | 1 mA | ±(1.0% + 5) | " | Disabled on power on, see below. | |
10.00 A | 10 mA | ±(1.0% + 2) | " | ||
A≈ | 3.000 mA | 1 µA | ±(1.5% + 2) | mq Curr., unit A, mqflags AC,DC,RMS | |
300.0 mA | 100 µA | " | |||
10.00 A | 10 mA | " | |||
Ω | 30.00 Ω | 10 mΩ | mq Res., unit Ω, mqflags - | ||
300.0 Ω | 100 mΩ | " | |||
3.000 kΩ | 1 Ω | " | |||
30.00 kΩ | 10 Ω | " | |||
300.0 kΩ | 100 Ω | " | |||
3.000 MΩ | 1 kΩ | " | |||
30.00 MΩ | 10 kΩ | " | |||
Diode/Cont. | 3.000 V– | 1 mV | mq V, unit V, mqflags DC,DIODE | Diode and cont. are identical on this device, just without beeper for diode. | |
°C | Pt100 –200.0 - +200.0 °C | 0.1 °C | 2 Kelvin + 5 | mq Temp., unit °C, mqflags - | |
Pt100 +200.0 - +850.0 °C | ±(1.0% + 5) | " | |||
Pt1000 –100.0 - +200.0 °C | 2 Kelvin + 2 | " | |||
Pt1000 +200.0 - +850.0 °C | ±(1.0% + 2) | " | |||
Data Hold | Disabled while IR interface is active. | ||||
MIN | mqflags += MIN | Influences only display, via IR flag is set, but actual current value is delivered. | |||
MAX | mqflags += MAX | Influences only display, via IR flag is set, but actual current value is delivered. |
To enable the ranges 300.0 µA, 3.000 mA and 3.000 A DC, switch function selector to circle with dot symbol and press yellow button. Wait until auto calibration of these ranges is finished ("CAL" in display disappears). After that the ranges are available in the mA resp. A function until multimeter powered off automatically or manually.
The column "sigrok result" contains in short form what the driver generates for the resp. data type.