{{Infobox multimeter
{{Infobox multimeter
| image          = [[File:Benning MM 12 - 01 - Front Sleeve.png|180px]]
| image          = [[File:Benning MM 12 - 01 - Front Sleeve.png|180px]]
| name            = <u>APPA 500 Series</u> <br/> APPA 501, 502, 503, 505, 506, 506B, 507 <br/> BENNING MM 12 <br/> IDEAL 61-497, 61-498 <br/> ISO-TECH/RS PRO IDM503, IDM505 <br/> Sefram 7351, 7352B, 7355, 7357 <br/> Voltcraft VC-930, VC-950
| name            = <u>APPA 500 Series</u> <br/> APPA 501, 502, 503, 505, 506, 506B, 507 <br/> BENNING MM 12 <br/> Elma 6600 <br/> IDEAL 61-497, 61-498 <br/> KPS DMM9000BT <br/> ISO-TECH/RS PRO IDM503, IDM505 <br/> Sefram 7351, 7352B, 7355, 7357 <br/> Voltcraft VC-930, VC-950
| status          = in progress
| status          = in progress
| source_code_dir = appa-dmm
| source_code_dir = appa-dmm
Line 16: Line 16:
|-
|-
! Model
! Model
! Known Brands
! Compatible devices
! Optical RS232/USB
! Optical RS232/USB
! Bluetooth LE
! Bluetooth LE
Line 64: Line 64:
|-
|-
| [http://www.appatech.com/en/product-553883/APPA-500-SERIES-MULTIMETERS-APPA-506-APPA-506B.html APPA 506B]
| [http://www.appatech.com/en/product-553883/APPA-500-SERIES-MULTIMETERS-APPA-506-APPA-506B.html APPA 506B]
| [[BENNING MM 12]] <br/> [https://www.sefram.com/en/products/multimeters/7352B-40-000-cts-trms-ac-dc-dmm-bluetooth.html Sefram 7352B]
| [[BENNING MM 12]] <br/> [https://kps-intl.com/na/en/product-list/content/192E036f8140 KPS DMM9000BT] <br/> [https://www.sefram.com/en/products/multimeters/7352B-40-000-cts-trms-ac-dc-dmm-bluetooth.html Sefram 7352B]
| X
| X
| X
| X
Line 72: Line 72:
|-
|-
| [http://www.appatech.com/en/product-553885/APPA-500-SERIES-MULTIMETERS-APPA-507.html APPA 507]
| [http://www.appatech.com/en/product-553885/APPA-500-SERIES-MULTIMETERS-APPA-507.html APPA 507]
| [https://www.cosinus.de/?artnr=9998402140 CMT 3507] <br/> [https://ht-instruments.de/produkte/multimeter/ht8100/ HT Instruments HT8100] <br/> [https://www.sefram.com/en/products/multimeters/7357-process-multimeter-50-000-counts-trms-ac-dc-with-current-source-and-loop-power.html Sefram 7357]
| [https://www.cosinus.de/?artnr=9998402140 CMT 3507] <br/> [https://elma-instruments.com/products/elma-6600-automation-multimeter.aspx Elma 6600] <br/> [https://ht-instruments.de/produkte/multimeter/ht8100/ HT Instruments HT8100] <br/> [https://www.sefram.com/en/products/multimeters/7357-process-multimeter-50-000-counts-trms-ac-dc-with-current-source-and-loop-power.html Sefram 7357]
| X
| X
|  
|  
Line 82: Line 82:
USB cable of APPA 500 Series based meters: [[Device cables#APPA IC-300U|APPA IC-300U]]
USB cable of APPA 500 Series based meters: [[Device cables#APPA IC-300U|APPA IC-300U]]


By the datasheet and feature list it seems to be that [[APPA 200 Series|APPA 208]] is the bench version of the APPA 506 handheld meters. Extra features of the 208 compared to the 506: AC 100-240V power supply (but it can still run on batteries), higher frequency measurement range at higher precision (4 MHz), duty cycle measurement  and an extra button for display light instead of the automatic light sensor of the 506.
By the datasheet and feature list it seems to be that [[APPA 200 Series|208]] is the bench version of the 506 handheld meters. Extra features of the 208 compared to the 506: AC 100-240V power supply (but it can still run on batteries), higher frequency measurement range at higher precision (4 MHz), duty cycle measurement  and an extra button for display light instead of the automatic light sensor of the 506.


''Important:'' Some of the older models of the Series 503/505, like the [[Voltcraft VC-950]], don't support the new APPA communication protocol with model identification. For these devices you need to manually select the appropriate driver (voltcraft-vc950, appa-500-legacy, etc.) in sigrok manually.
''Important:'' Some of the older models of the Series 503/505, like the [[Voltcraft VC-950|VC-950]], don't support the new APPA communication protocol with model identification. For these devices you need to manually select the appropriate driver (voltcraft-vc950, appa-500-legacy, etc.) in sigrok manually.





Latest revision as of 11:49, 18 August 2022

APPA 500 Series
APPA 501, 502, 503, 505, 506, 506B, 507
BENNING MM 12
Elma 6600
IDEAL 61-497, 61-498
KPS DMM9000BT
ISO-TECH/RS PRO IDM503, IDM505
Sefram 7351, 7352B, 7355, 7357
Voltcraft VC-930, VC-950
Benning MM 12 - 01 - Front Sleeve.png
Status in progress
Source code appa-dmm
IEC 61010-1 CAT IV (600V) / CAT III (1000V)
Connectivity Optical (RS232/USB), Bluetooth LE (depending on model)
Website appatech.com

The APPA 500 is a wide range of 6.000 to 100.000 counts, CAT III (1000V) / CAT IV (600V) handheld digital multimeters with optical RS232 / USB connectivity. Model variant 506B also has built-in Bluetooth LE connectivity.

For more information on the sigrok-integration see: APPA Multimeters in sigrok using the appa-dmm driver

Model Compatible devices Optical RS232/USB Bluetooth LE Support level Comments
APPA 501 X implemented, untested
APPA 502 X implemented, untested
APPA 503 CMT 3503
IDEAL 61-497
ISO-TECH IDM503
Sefram 7351
Voltcraft VC-930
X implemented, untested
APPA 505 IDEAL 61-498
ISO-TECH & RS PRO IDM505
Sefram 7355
Voltcraft VC-950
X good
APPA 506 X good
APPA 506B BENNING MM 12
KPS DMM9000BT
Sefram 7352B
X X good
APPA 507 CMT 3507
Elma 6600
HT Instruments HT8100
Sefram 7357
X implemented, untested Unknown ID

USB cable of APPA 500 Series based meters: APPA IC-300U

By the datasheet and feature list it seems to be that 208 is the bench version of the 506 handheld meters. Extra features of the 208 compared to the 506: AC 100-240V power supply (but it can still run on batteries), higher frequency measurement range at higher precision (4 MHz), duty cycle measurement and an extra button for display light instead of the automatic light sensor of the 506.