Difference between revisions of "APPA Multimeters"

From sigrok
Jump to navigation Jump to search
Line 65: Line 65:
|}
|}


= Supported Models =
  ID    | Model    | Brand Name            | OPT | BLE | State
  ------|-----------|-----------------------|:---:|:---:|---------------
  0x01  | 150B      | APPA 155B            |    |  X  | untested
  0x01  | 150B      | APPA 156B            |    |  X  | untested
  0x01  | 150B      | APPA 157B            |    |  X  | untested
  0x01  | 150B      | APPA 158B            |    |  X  | untested
  0x01  | 150B      | BENNING CM 12        |    |  X  | untested
  0x0c  | 172      | APPA 172B            |    |  X  | untested
  0x0d  | 172      | BENNING CM 9-2        |    |  X  | untested
  0x0d  | 173      | APPA 173B            |    |  X  | untested
  0x0d  | 173      | BENNING CM 10-1      |    |  X  | untested
  0x0e  | 175      | APPA 175B            |    |  X  | untested
  0x0f  | 177      | APPA 177B            |    |  X  | untested
  0x0f  | 177      | BENNING CM 10-PV      |    |  X  | untested
  0x14  | 179      | APPA 179B            |    |  X  | untested
  0x03  | 208      | APPA 208              |  X  |    | untested
  0x04  | 208B      | APPA 208B            |  X  |  X  | untested
  0x07  | 501      | APPA 501              |  X  |    | untested
  0x08  | 502      | APPA 502              |  X  |    | untested
  0x15  | 503      | APPA 503              |  X  |    | untested
  0x15  | 503      | CMT 3503              |  X  |    | untested
  0x15  | 503      | Voltcraft VC-930      |  X  |    | experimental
  0x15  | 503      | ISO-TECH IDM503      |  X  |    | untested
  0x16  | 505      | APPA 505              |  X  |    | untested
  0x16  | 505      | RS PRO IDM505        |  X  |    | untested
  0x16  | 505      | Sefram 7355          |  X  |    | untested
  0x16  | 505      | Voltcraft VC-950      |  X  |    | experimental
  0x05  | 506      | APPA 506              |  X  |    | ok
  0x05  | 506      | Sefram 7352          |  X  |    | ok
  0x06  | 506B      | APPA 506B            |  X  |  X  | ok
  0x06  | 506B      | BENNING MM 12        |  X  |  X  | ok
  0x06  | 506B      | Sefram 7352B          |  X  |  X  | ok
  N/A  | 507      | APPA 507              |  X  |    | experimental
  N/A  | 507      | CMT 3507              |  X  |    | experimental
  N/A  | 507      | HT Instruments HT8100 |  X  |    | experimental
  0x12  | A17N      | APPA A17N            |    |  X  | untested
  0x13  | S0        | APPA S0              |    |  X  | untested
  0x09  | S1        | APPA S1              |    |  X  | untested
  0x09  | S1        | RS PRO S1            |    |  X  | untested
  0x0a  | S2        | APPA S2              |    |  X  | untested
  0x0a  | S2        | BENNING MM 10        |    |  X  | untested
  0x0a  | S2        | RS PRO S2            |    |  X  | untested
  0x0b  | S3        | APPA S3              |    |  X  | untested
  0x0b  | S3        | BENNING MM 10-PV      |    |  X  | untested
  0x0b  | S3        | RS PRO S3            |    |  X  | untested
  0x10  | SFLEX_10A | APPA sFlex-10A        |    |  X  | untested
  0x11  | SFLEX_18A | APPA sFlex-18A        |    |  X  | untested
BLE: Bluetooth LE, OPT: Optical serial interface
Place keep this table in sync with "appa_b.h"!


[[Category:Device]]
[[Category:Device]]

Revision as of 22:01, 4 November 2020

Multimeters and current clamps with optical serial (USB) and BLE interface supported by the "appa-b" driver.

The driver supporting APPA-based devices ("appa-b" in sigrok) has been created and will be included in mainline sigrok once it passes acception (more details in pull request #99).

Series

Series Type Optical RS232/USB Bluetooth LE Comments
APPA 150B Series Clamp Multimeter X
APPA 170 Series Clamp Multimeter X
APPA 200 Series Bench Multimeter X X*
APPA 500 Series Handheld Multimeter X X*
APPA A Series Clamp Multimeter X
APPA S Series Handheld Multimeter X
APPA sFlex Series Clamp Multimeter X