Difference between revisions of "Mooshim Engineering Mooshimeter"

From sigrok
Jump to navigation Jump to search
m (Category Bluetooth added)
 
(11 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{Infobox multimeter
{{Infobox multimeter
| image          = [[File:Mooshimeter-2X01A.jpg|180px]]
| image          = [[File:Mooshimeter_mugshot.png|180px]]
| name            = Mooshimeter DMM-BLE-2X01A
| name            = Mooshimeter
| status          = planned
| status          = supported
| source_code_dir = ble-dmm
| source_code_dir = mooshimeter-dmm
| counts          = 24 bit
| counts          = 24 bit
| categories      = CAT III (600V)
| categories      = CAT III (600V)
| connectivity    = ble (aka Bluetooth Smart) ONLY
| connectivity    = BLE
| measurements    = voltage, resistance, diode, continuity, frequency, current, temperature
| measurements    = voltage, resistance, diode, continuity, frequency, current, temperature
| features        = autorange, logging to SD card, current / voltage simultaneously
| features        = autorange, logging to SD card, current / voltage simultaneously
| website        = https://moosh.im/mooshimeter/
| website        = [https://moosh.im/mooshimeter/ moosh.im]
}}
}}


The '''Mooshimeter''' is a 24-bit, two channel, CAT III (600V) remote access digital multimeter with Bluetooth Low Energy connectivity.
The '''Mooshim Engineering Mooshimeter''' (DMM-BLE-2X01A) is a 24-bit, two channel, CAT III (600V) remote access digital multimeter with Bluetooth Low Energy (BLE) connectivity.
 
See [[Mooshim Engineering Mooshimeter/Info]] for more details (such as '''hcitool/gatttool''' output) about the device.


== Hardware ==
== Hardware ==
Line 18: Line 20:
'''Multimeter''':
'''Multimeter''':


* BLE SoC: [http://www.ti.com/product/CC2540 TI CC2540] (custom firmware)
* ADC: [http://www.ti.com/product/ADS1292 TI ADS1292]


== Photos ==
== Photos ==
Line 24: Line 28:


<gallery>
<gallery>
File:Mooshimeter-2X01A.jpg
File:Mooshimeter-2X01A.jpg|<small>Device, top</small>
File:Mooshimeter_Component_Side.jpg
File:Mooshimeter_Component_Side.jpg|<small>PCB, top</small>
File:Mooshimeter_Connection_Side.jpg
File:Mooshimeter_Connection_Side.jpg|<small>PCB, bottom</small>
File:Mooshimeter_BLE_SoC.jpg
File:Mooshimeter_BLE_SoC.jpg|<small>TI CC2540</small>
File:Mooshimeter_ADC.jpg|<small>TI ADS1292</small>
</gallery>
</gallery>
'''Another teardown''':
<gallery>
File:Mooshimeter top.jpg|<small>Device, top</small>
File:Mooshimeter bottom.jpg|<small>Device, bottom</small>
File:Mooshimeter pcb top.jpg|<small>PCB, top</small>
File:Mooshimeter pcb bottom.jpg|<small>PCB, bottom</small>
File:Mooshimeter case.jpg|<small>Device, case</small>
</gallery>
== Usage ==
Example usage using [[sigrok-cli]]:
<small>
$ '''sigrok-cli --driver mooshimeter-dmm:conn=68-9e-19-cb-e1-71 --scan'''
The following devices were found:
mooshimeter-dmm - Mooshim Engineering Mooshimeter with 3 channels: CH1 CH2 P
$ '''sigrok-cli --driver mooshimeter-dmm:conn=68-9e-19-cb-e1-71 --show'''
Driver functions:
    Multimeter
Scan options:
    conn
mooshimeter-dmm - Mooshim Engineering Mooshimeter with 3 channels: CH1 CH2 P
Supported configuration options:
    continuous: on, off
    limit_time:
    avg_samples:  - supported values:
      32
      64 (current)
      128
      256
    samplerate - supported samplerates:
      125 Hz
      250 Hz
      500 Hz
      1 kHz
      2 kHz
      4 kHz
      8 kHz
    channel_config:
$ '''sigrok-cli --driver mooshimeter-dmm:conn=68-9e-19-cb-e1-71 --samples 4'''
CH1: 0.00 A DC AUTO
CH2: 0.00 V DC AUTO
CH1: 0.00 A DC AUTO
CH2: 0.00 V DC AUTO
$ '''sigrok-cli --driver mooshimeter-dmm:conn=68-9e-19-cb-e1-71 -c channel_config="Aux;0.1/T" --samples 4'''
CH1: -0.19 V DC
CH2: 298.30 °C DC AUTO
CH1: -0.19 V DC
CH2: 298.30 °C DC AUTO
</small>
See also [[libsigrok]]'s [https://sigrok.org/gitweb/?p=libsigrok.git;a=blob;f=README.devices;h=a7e50a395302d9b5a6e9d351a138ea54dc5b8e0b;hb=HEAD#l480 README.devices] for more info.


== Protocol ==
== Protocol ==


Though the BLE SoC powering the Mooshimeter appears to be a TI CC2540,
the firmware running on it is not the standard "UART to BLE" that is
commonly found on them. Instead, it implements the entire meter control
and its own custom protocol.
The Mooshimeter protocol is broken down into several layers in a
communication stack.
The lowest layer is the BLE GATT stack, which provides two characteristics:
one to write packets to the meter and one to receive them from it. The
MTU for a packet in either direction is 20 bytes. This is implemented
in the GATT abstraction, so we can talk to it via simple write commands
and a read callback.
The next layer is the serial stream: each BLE packet in either direction
has a 1-byte header of a sequence number. Despite what the documentation
says, this is present in both directions (not just meter output) and is
NOT reset on the meter output on BLE connection. So the implementation
here needs to provide an output sequence number and incoming reassembly
for out of order packets (I haven't actually observed this, but
supposedly it happens, which is why the sequence number is present).
So the structure of packets received looks like:
{| class="wikitable"
! 1 byte
! 1-19 bytes
|-
| SeqNum
| Serial Data
|}
On top of the serial layer is the "config tree" layer. This is how
the meter actually exposes data and configuration. The tree itself
is composed of nodes, each with a string name, data type, and a list
of children (zero or more). For value containing (non-informational)
nodes, they also contain a 7-bit unique identifier.
Access to the config tree is provided by packets on the serial stream, each packet
has a 1-byte header, where the uppermost bit (0x80) is set when writing
(i.e. never by the meter) and the remaining 7 bits are the node identifier.
The length of the packets varies based on the datatype of the tree node.
This means that any lost/dropped packets can make the stream unrecoverable
(i.e. there's no defined sync method other that reconnection).
Packets are emitted by the meter in response to a read or write command (write
commands simply back the value) and at unsolicited times by the meter
(e.g. continuous sampling and periodic battery voltage). A read packet
send to the meter looks like:
{| class="wikitable"
! 1 bit
! 7 bits
|-
| 0
| NodeID
|}
In response to the read, the meter will send:
{| class="wikitable"
! 1 bit
! 7 bits
! 1-N bytes
|-
| 0
| NodeID
| NodeValue
|}
A write packet sent to the meter:
{| class="wikitable"
! 1 bit
! 7 bits
! 1-N bytes |
|-
| 1
| NodeID
| NodeValue
|}
In response to the write, the meter will send a read response:
{| class="wikitable"
! 1 bit
! 7 bits
! 1-N bytes
|-
| 0
| NodeID
| NodeValue
|}
For the data in the tree, all values are little endian (least significant
bytes first). The supported type codes are:
{| class="wikitable"
! Code
! Description
! Wire Format
|-
|  0  || Plain      ||                                       
|-
|  1  || Link        ||                                       
|-
|  2  || Chooser    || uint8_t                               
|-
|  3  || U8          || uint8_t                               
|-
|  4  || U16        || uint16_t                             
|-
|  5  || U32        || uint32_t                             
|-
|  6  || S8          || int8_t                               
|-
|  7  || S16        || int16_t 
|-                           
|  8  || S32        || int32_t                               
|-
|  9  || String      || uint16_t length; char value[length]   
|-
|  10  || Binary      || uint16_t length; uint8_t value[length]
|-
|  11  || Float      || float                                 
|}
Plain and Link nodes are present to provide information and/or choices
but do not provide commands codes for direct access (see serialization
below). Chooser nodes are written with indices described by their Plain
type children (e.g. to select a choice identified by the second child
of a chooser, write 1 to the chooser node itself).
On initial connection only three nodes at fixed identifiers are available:
{| class="wikitable"
! Node           
! ID
! Type 
|-
| ADMIN:CRC32      || 0  || U32   
|-
| ADMIN:TREE      || 1  || Binary
|-
| ADMIN:DIAGNOSTIC || 2  || String
|}
The handshake sequence is to read the contents of ADMIN:TREE, which contains
the zlib compressed tree serialization, then write the CRC of the compressed
data back to ADMIN:CRC32 (which the meter will echo back). Only after
that is done will the meter accept access to the rest of the tree.
After zlib decompression the tree serialization is as follows:
{| class="wikitable"
! Type       
! Description
|-
| uint8_t      || The node data type code from above 
|-
| uint8_t      || Name length                       
|-
| char[length] || Node name (e.g. "ADMIN" or "CRC32")
|-
| uint8_t      || Number of children                 
|-
| Node[count]  || Child serialization (length varies)
|}
Once the tree has been deserialized, each node needs it identifier
assigned. This is a depth first tree walk, assigning sequential identifiers
first the the current node (if it needs one), then repeating recursively
for each of its children. Plain and Link nodes are skipped in assignment
but not the walk (so the recursion still happens, but the identifier
is not incremented).
So, for example a write to the ADMIN:CRC32 as part of the handshake would
be a write by us (the host):
{| class="wikitable"
! SerSeq
! NodeID
! U32 (CRC) 
|-
! 1 byte
! 1 byte
! 4 bytes
|-
| 0x01 
| 0x80 
| 0xDEADBEEF
|}
The meter will respond with a packet like:
{| class="wikitable"
! SerSeq
! NodeID
! U32 (CRC)
|-
! 1 byte
! 1 byte
! 4 bytes 
|-
|  0x42 
|  0x00 
| 0xDEADBEEF
|}


Notes:
A spontaneous error from the meter (e.g. in response to a bad packet)
can be emitted like:
 
{| class="wikitable"
! SerSeq
! NodeID
! U16 (len) 
! String     
|-
! 1 byte
! 1 byte
! 2 bytes 
! len (=8) bytes 
|-
| 0xAB 
| 0x20 
| 0x0008 
| BAD\x20DATA 
|}
 
The config tree at the time of writing looks like:
 
<small>
    <ROOT> (PLAIN)
        ADMIN (PLAIN)
                CRC32 (U32) = 0
                TREE (BIN) = 1
                DIAGNOSTIC (STR) = 2
        PCB_VERSION (U8) = 3
        NAME (STR) = 4
        TIME_UTC (U32) = 5
        TIME_UTC_MS (U16) = 6
        BAT_V (FLT) = 7
        REBOOT (CHOOSER) = 8
                NORMAL (PLAIN)
                SHIPMODE (PLAIN)
        SAMPLING (PLAIN)
                RATE (CHOOSER) = 9
                        125 (PLAIN)
                        250 (PLAIN)
                        500 (PLAIN)
                        1000 (PLAIN)
                        2000 (PLAIN)
                        4000 (PLAIN)
                        8000 (PLAIN)
                DEPTH (CHOOSER) = 10
                        32 (PLAIN)
                        64 (PLAIN)
                        128 (PLAIN)
                        256 (PLAIN)
                TRIGGER (CHOOSER) = 11
                        OFF (PLAIN)
                        SINGLE (PLAIN)
                        CONTINUOUS (PLAIN)
        LOG (PLAIN)
                ON (U8) = 12
                INTERVAL (U16) = 13
                STATUS (U8) = 14
                POLLDIR (U8) = 15
                INFO (PLAIN)
                        INDEX (U16) = 16
                        END_TIME (U32) = 17
                        N_BYTES (U32) = 18
                STREAM (PLAIN)
                        INDEX (U16) = 19
                        OFFSET (U32) = 20
                        DATA (BIN) = 21
        CH1 (PLAIN)
                MAPPING (CHOOSER) = 22
                        CURRENT (PLAIN)
                                10 (PLAIN)
                        TEMP (PLAIN)
                                350 (PLAIN)
                        SHARED (LINK)
                RANGE_I (U8) = 23
                ANALYSIS (CHOOSER) = 24
                        MEAN (PLAIN)
                        RMS (PLAIN)
                        BUFFER (PLAIN)
                VALUE (FLT) = 25
                OFFSET (FLT) = 26
                BUF (BIN) = 27
                BUF_BPS (U8) = 28
                BUF_LSB2NATIVE (FLT) = 29
        CH2 (PLAIN)
                MAPPING (CHOOSER) = 30
                        VOLTAGE (PLAIN)
                                60 (PLAIN)
                                600 (PLAIN)
                        TEMP (PLAIN)
                                350 (PLAIN)
                        SHARED (LINK)
                RANGE_I (U8) = 31
                ANALYSIS (CHOOSER) = 32
                        MEAN (PLAIN)
                        RMS (PLAIN)
                        BUFFER (PLAIN)
                VALUE (FLT) = 33
                OFFSET (FLT) = 34
                BUF (BIN) = 35
                BUF_BPS (U8) = 36
                BUF_LSB2NATIVE (FLT) = 37
        SHARED (CHOOSER) = 38
                AUX_V (PLAIN)
                        0.1 (PLAIN)
                        0.3 (PLAIN)
                        1.2 (PLAIN)
                RESISTANCE (PLAIN)
                        1000.0 (PLAIN)
                        10000.0 (PLAIN)
                        100000.0 (PLAIN)
                        1000000.0 (PLAIN)
                        10000000.0 (PLAIN)
                DIODE (PLAIN)
                        1.2 (PLAIN)
        REAL_PWR (FLT) = 39
</small>


== Resources ==
== Resources ==
Line 39: Line 425:
* [https://moosh.im/mooshimeter/specs/ Specs]
* [https://moosh.im/mooshimeter/specs/ Specs]
* [https://moosh.im/s/manual/MooshimeterManualRev1.pdf Manual]
* [https://moosh.im/s/manual/MooshimeterManualRev1.pdf Manual]
* [https://play.google.com/store/apps/details?id=com.mooshim.mooshimeter&hl=en_GB Vendor software (Android)] [https://github.com/mooshim/Mooshimeter-AndroidApp sources]
* [https://play.google.com/store/apps/details?id=com.mooshim.mooshimeter&hl=en_GB Vendor software (Android)] ([https://github.com/mooshim/Mooshimeter-AndroidApp sources])
* [https://itunes.apple.com/us/app/mooshimeter/id945898277?mt=8 Vendor software (iOS)]
* [https://itunes.apple.com/us/app/mooshimeter/id945898277?mt=8 Vendor software (iOS)]


[[Category:Device]]
[[Category:Device]]
[[Category:Multimeter]]
[[Category:Multimeter]]
[[Category:Planned]]
[[Category:Bluetooth]]
[[Category:Supported]]

Latest revision as of 14:40, 2 November 2020

Mooshimeter
Mooshimeter mugshot.png
Status supported
Source code mooshimeter-dmm
Counts 24 bit
IEC 61010-1 CAT III (600V)
Connectivity BLE
Measurements voltage, resistance, diode, continuity, frequency, current, temperature
Features autorange, logging to SD card, current / voltage simultaneously
Website moosh.im

The Mooshim Engineering Mooshimeter (DMM-BLE-2X01A) is a 24-bit, two channel, CAT III (600V) remote access digital multimeter with Bluetooth Low Energy (BLE) connectivity.

See Mooshim Engineering Mooshimeter/Info for more details (such as hcitool/gatttool output) about the device.

Hardware

Multimeter:

Photos

Multimeter:

Another teardown:

Usage

Example usage using sigrok-cli:

$ sigrok-cli --driver mooshimeter-dmm:conn=68-9e-19-cb-e1-71 --scan
The following devices were found:
mooshimeter-dmm - Mooshim Engineering Mooshimeter with 3 channels: CH1 CH2 P

$ sigrok-cli --driver mooshimeter-dmm:conn=68-9e-19-cb-e1-71 --show
Driver functions:
   Multimeter
Scan options:
   conn
mooshimeter-dmm - Mooshim Engineering Mooshimeter with 3 channels: CH1 CH2 P
Supported configuration options:
   continuous: on, off
   limit_time: 
   avg_samples:  - supported values:
     32
     64 (current)
     128
     256
   samplerate - supported samplerates:
     125 Hz
     250 Hz
     500 Hz
     1 kHz
     2 kHz
     4 kHz
     8 kHz
   channel_config: 

$ sigrok-cli --driver mooshimeter-dmm:conn=68-9e-19-cb-e1-71 --samples 4
CH1: 0.00 A DC AUTO
CH2: 0.00 V DC AUTO
CH1: 0.00 A DC AUTO
CH2: 0.00 V DC AUTO

$ sigrok-cli --driver mooshimeter-dmm:conn=68-9e-19-cb-e1-71 -c channel_config="Aux;0.1/T" --samples 4
CH1: -0.19 V DC
CH2: 298.30 °C DC AUTO
CH1: -0.19 V DC
CH2: 298.30 °C DC AUTO

See also libsigrok's README.devices for more info.

Protocol

Though the BLE SoC powering the Mooshimeter appears to be a TI CC2540, the firmware running on it is not the standard "UART to BLE" that is commonly found on them. Instead, it implements the entire meter control and its own custom protocol.

The Mooshimeter protocol is broken down into several layers in a communication stack.

The lowest layer is the BLE GATT stack, which provides two characteristics: one to write packets to the meter and one to receive them from it. The MTU for a packet in either direction is 20 bytes. This is implemented in the GATT abstraction, so we can talk to it via simple write commands and a read callback.

The next layer is the serial stream: each BLE packet in either direction has a 1-byte header of a sequence number. Despite what the documentation says, this is present in both directions (not just meter output) and is NOT reset on the meter output on BLE connection. So the implementation here needs to provide an output sequence number and incoming reassembly for out of order packets (I haven't actually observed this, but supposedly it happens, which is why the sequence number is present). So the structure of packets received looks like:

1 byte 1-19 bytes
SeqNum Serial Data

On top of the serial layer is the "config tree" layer. This is how the meter actually exposes data and configuration. The tree itself is composed of nodes, each with a string name, data type, and a list of children (zero or more). For value containing (non-informational) nodes, they also contain a 7-bit unique identifier.

Access to the config tree is provided by packets on the serial stream, each packet has a 1-byte header, where the uppermost bit (0x80) is set when writing (i.e. never by the meter) and the remaining 7 bits are the node identifier.

The length of the packets varies based on the datatype of the tree node. This means that any lost/dropped packets can make the stream unrecoverable (i.e. there's no defined sync method other that reconnection).

Packets are emitted by the meter in response to a read or write command (write commands simply back the value) and at unsolicited times by the meter (e.g. continuous sampling and periodic battery voltage). A read packet send to the meter looks like:

1 bit 7 bits
0 NodeID

In response to the read, the meter will send:

1 bit 7 bits 1-N bytes
0 NodeID NodeValue

A write packet sent to the meter:

1 bit 7 bits
1 NodeID NodeValue

In response to the write, the meter will send a read response:

1 bit 7 bits 1-N bytes
0 NodeID NodeValue

For the data in the tree, all values are little endian (least significant bytes first). The supported type codes are:

Code Description Wire Format
0 Plain
1 Link
2 Chooser uint8_t
3 U8 uint8_t
4 U16 uint16_t
5 U32 uint32_t
6 S8 int8_t
7 S16 int16_t
8 S32 int32_t
9 String uint16_t length; char value[length]
10 Binary uint16_t length; uint8_t value[length]
11 Float float

Plain and Link nodes are present to provide information and/or choices but do not provide commands codes for direct access (see serialization below). Chooser nodes are written with indices described by their Plain type children (e.g. to select a choice identified by the second child of a chooser, write 1 to the chooser node itself).

On initial connection only three nodes at fixed identifiers are available:

Node ID Type
ADMIN:CRC32 0 U32
ADMIN:TREE 1 Binary
ADMIN:DIAGNOSTIC 2 String

The handshake sequence is to read the contents of ADMIN:TREE, which contains the zlib compressed tree serialization, then write the CRC of the compressed data back to ADMIN:CRC32 (which the meter will echo back). Only after that is done will the meter accept access to the rest of the tree.

After zlib decompression the tree serialization is as follows:

Type Description
uint8_t The node data type code from above
uint8_t Name length
char[length] Node name (e.g. "ADMIN" or "CRC32")
uint8_t Number of children
Node[count] Child serialization (length varies)

Once the tree has been deserialized, each node needs it identifier assigned. This is a depth first tree walk, assigning sequential identifiers first the the current node (if it needs one), then repeating recursively for each of its children. Plain and Link nodes are skipped in assignment but not the walk (so the recursion still happens, but the identifier is not incremented).

So, for example a write to the ADMIN:CRC32 as part of the handshake would be a write by us (the host):

SerSeq NodeID U32 (CRC)
1 byte 1 byte 4 bytes
0x01 0x80 0xDEADBEEF

The meter will respond with a packet like:

SerSeq NodeID U32 (CRC)
1 byte 1 byte 4 bytes
0x42 0x00 0xDEADBEEF

A spontaneous error from the meter (e.g. in response to a bad packet) can be emitted like:

SerSeq NodeID U16 (len) String
1 byte 1 byte 2 bytes len (=8) bytes
0xAB 0x20 0x0008 BAD\x20DATA

The config tree at the time of writing looks like:

   <ROOT> (PLAIN)
       ADMIN (PLAIN)
               CRC32 (U32) = 0
               TREE (BIN) = 1
               DIAGNOSTIC (STR) = 2
       PCB_VERSION (U8) = 3
       NAME (STR) = 4
       TIME_UTC (U32) = 5
       TIME_UTC_MS (U16) = 6
       BAT_V (FLT) = 7
       REBOOT (CHOOSER) = 8
               NORMAL (PLAIN)
               SHIPMODE (PLAIN)
       SAMPLING (PLAIN)
               RATE (CHOOSER) = 9
                       125 (PLAIN)
                       250 (PLAIN)
                       500 (PLAIN)
                       1000 (PLAIN)
                       2000 (PLAIN)
                       4000 (PLAIN)
                       8000 (PLAIN)
               DEPTH (CHOOSER) = 10
                       32 (PLAIN)
                       64 (PLAIN)
                       128 (PLAIN)
                       256 (PLAIN)
               TRIGGER (CHOOSER) = 11
                       OFF (PLAIN)
                       SINGLE (PLAIN)
                       CONTINUOUS (PLAIN)
       LOG (PLAIN)
               ON (U8) = 12
               INTERVAL (U16) = 13
               STATUS (U8) = 14
               POLLDIR (U8) = 15
               INFO (PLAIN)
                       INDEX (U16) = 16
                       END_TIME (U32) = 17
                       N_BYTES (U32) = 18
               STREAM (PLAIN)
                       INDEX (U16) = 19
                       OFFSET (U32) = 20
                       DATA (BIN) = 21
       CH1 (PLAIN)
               MAPPING (CHOOSER) = 22
                       CURRENT (PLAIN)
                               10 (PLAIN)
                       TEMP (PLAIN)
                               350 (PLAIN)
                       SHARED (LINK)
               RANGE_I (U8) = 23
               ANALYSIS (CHOOSER) = 24
                       MEAN (PLAIN)
                       RMS (PLAIN)
                       BUFFER (PLAIN)
               VALUE (FLT) = 25
               OFFSET (FLT) = 26
               BUF (BIN) = 27
               BUF_BPS (U8) = 28
               BUF_LSB2NATIVE (FLT) = 29
       CH2 (PLAIN)
               MAPPING (CHOOSER) = 30
                       VOLTAGE (PLAIN)
                               60 (PLAIN)
                               600 (PLAIN)
                       TEMP (PLAIN)
                               350 (PLAIN)
                       SHARED (LINK)
               RANGE_I (U8) = 31
               ANALYSIS (CHOOSER) = 32
                       MEAN (PLAIN)
                       RMS (PLAIN)
                       BUFFER (PLAIN)
               VALUE (FLT) = 33
               OFFSET (FLT) = 34
               BUF (BIN) = 35
               BUF_BPS (U8) = 36
               BUF_LSB2NATIVE (FLT) = 37
       SHARED (CHOOSER) = 38
               AUX_V (PLAIN)
                       0.1 (PLAIN)
                       0.3 (PLAIN)
                       1.2 (PLAIN)
               RESISTANCE (PLAIN)
                       1000.0 (PLAIN)
                       10000.0 (PLAIN)
                       100000.0 (PLAIN)
                       1000000.0 (PLAIN)
                       10000000.0 (PLAIN)
               DIODE (PLAIN)
                       1.2 (PLAIN)
       REAL_PWR (FLT) = 39

Resources