RDTech DPS/DPH series
Rdtech-dps.png
Status planned
Source code rdtech-dps
Channels 1
Voltage/current (CH1) varies
Connectivity serial over USB/Bluetooth
Features settable values, settable output.
Website rdtech.aliexpress.com

Please note: This page is a work in progress, more to come.

HangZhou RuiDeng Technologies sells a range of low-cost programmable DC-DC switching PSU modules in either buck or buck/boost configuration. The communication versions are controllable via Modbus over a USB-Serial or Bluetooth connection.

Hardware

Model Topology Voltage Current Max Power
DPS3005 Buck 0-30V 0-5A 160W
DPS5005 Buck 0-50V 0-5A 250W
DPH5005 Buck/Boost 0-50V 0-5A 250W
DPS5015 Buck 0-50V 0-15A 750W
DPS5020 Buck 0-50V 0-20A 1000W
DPS8005 Buck 0-80V 0-5A 408W

Protocol

Modbus RTU. Baudrate defaults to 9600 and modbus address to 001, both can be changed by holding V/▲ at power on.

Manual Operation

The dial is used to change values, pressing the dial in changes the selected digit. Holding in for 3s enables the keylock.

V/▲ selects the voltage target; holding for 3s selects the M1 preset.

A/▼ selects the current limit; holding for 3s selects the M2 preset.

SET brings up the settings menu; holding for 3s allows selecting any preset from M1-M9 using the dial.

When a preset is selected it is automatically copied into preset M0, which is the active configuration.

Settings menu allows configuring of the over-voltage, over-current and over-power protection thresholds as well as saving to presets M1-M9. Arrows select option, dial button selects value and digit, SET exits option or menu.

Status on power up

Can be configured with the S-INI option in the settings menu. Default is off. Selecting a preset will overwrite this value. The ON/OFF setting in M-PRE determines the output state when the preset is selected. OFF will turn the output off, ON will maintain the current output state.

Saving a preset

In the settings menu, set M-PRE to desired preset (M1-M9). Change other options as desired. Return to the M-PRE setting (the value must be selected) and hold SET for 3s. Do not exit the menu before this or the settings will be lost.