Revision as of 11:41, 19 February 2018
Status | planned |
---|---|
Source code | rdtech-dps |
Channels | 1 |
Voltage/current (CH1) | varies |
Connectivity | serial over USB/Bluetooth |
Features | settable values, settable output. |
Website | rdtech.aliexpress.com |
Please note: This page is a work in progress, more to come.
HangZhou RuiDeng Technologies sells a range of low-cost programmable DC-DC switching PSU modules in either buck or buck/boost configuration. The communication versions are controllable via Modbus over a USB-Serial or Bluetooth connection.
Hardware
Model | Topology | Voltage | Current | Max Power |
---|---|---|---|---|
DPS3005 | Buck | 0-30V | 0-5A | 160W |
DPS5005 | Buck | 0-50V | 0-5A | 250W |
DPH5005 | Buck/Boost | 0-50V | 0-5A | 250W |
DPS5015 | Buck | 0-50V | 0-15A | 750W |
DPS5020 | Buck | 0-50V | 0-20A | 1000W |
DPS8005 | Buck | 0-80V | 0-5A | 408W |
Protocol
Modbus RTU. Baudrate defaults to 9600 and modbus address to 001, both can be changed by holding V/▲ at power on.
Manual Operation
The dial is used to change values, pressing the dial in changes the selected digit. Holding in for 3s enables the keylock.
V/▲ selects the voltage target; holding for 3s selects the M1 preset.
A/▼ selects the current limit; holding for 3s selects the M2 preset.
SET brings up the settings menu; holding for 3s allows selecting any preset from M1-M9 using the dial.
When a preset is selected it is automatically copied into preset M0, which is the active setting.
Settings menu allows configuring of the over-voltage, over-current and over-power protection thresholds as well as saving to presets M1-M9. Arrows select option, dial button selects value and digit, SET exits option or menu.
Status on power up
Can be configured with the S-INI option in the settings menu. Default is off. Selecting a preset will overwrite this value. The ON/OFF setting in M-PRE determines the output state when the preset is selected. OFF will turn the output off, ON will maintain the current output state.
Saving a preset
In the settings menu, set M-PRE to desired preset (M1-M9). Change other options as desired. Return to the M-PRE setting (the value must be selected) and hold SET for 3s. Do not exit the menu before this or the settings will be lost.