Line 1: Line 1:
{{Infobox multimeter
{{Infobox multimeter
| image          = <!-- [[File:Gmc metrahit 14a logo.png|180px]] -->
| image          = [[File:HT410_logo.png|180px]]
| name            = HT Instruments HT410
| name            = HT Instruments HT410
| status          = supported
| status          = supported
| source_code_dir = gmx_mh_1x_2x
| source_code_dir = gmc-mh-1x-2x
| counts          = 3100
| counts          = 3100
| categories      = CAT III 1000 V, CAT IV 600 V
| categories      = CAT III 1000 V, CAT IV 600 V
Line 9: Line 9:
| measurements    = voltage, current, resistance, temperature, diode, continuity
| measurements    = voltage, current, resistance, temperature, diode, continuity
| features        = autorange, data hold, bargraph
| features        = autorange, data hold, bargraph
| website        = [http://www.ht-instruments.com/en/products-ht/ht410]  
| website        = [http://www.ht-instruments.com/en/products-ht/ht410 ht-instruments.com]  
}}
}}


The ''HT Instruments HT410'' is a 3100 counts handheld digital multimeter with IR (RS232) connectivity.
The '''HT Instruments HT410''' is a 3100 counts handheld digital multimeter with IR (RS232) connectivity.


It is probably a low-cost OEM version of the [[Gossen Metrawatt]] ''Metrahit 15S'', ''Rishabh 15S'' or a similar model with much worse specs, although the actual accuracy of [[User:Matthias_Heidbrink|Matthias']] device seems to be better than the specs, according to the calibration certificate (!) that came with it. At least the test cords that come with it are Rishabh brand.  
It is probably a low-cost OEM version of the ''Rishabh 15S'' (see [[Gossen Metrawatt]], ''Metrahit 15S'') or a similar model with much worse specs, although the actual accuracy of [[User:Matthias_Heidbrink|Matthias']] device seems to be better than the specs, according to the calibration certificate (!) that came with it. At least the test cords that come with it are Rishabh brand and cheaper quality than orginal Gossen Metrawatt ones, although they look the same. The same seems to be true for case and sleeve.


The IR connectivity is undocumented, possibly because no IR interface or software is available from the manufacturer. To enable sending data, press the DATA button while powering it on. See [[Gossen Metrawatt#Metrahit_1x.2F2x_series|here]] for fitting interfaces.
The IR connectivity is undocumented, possibly because no IR interface or software is available from the manufacturer. To enable sending data, press the DATA button while powering it on. See [[Gossen Metrawatt#Metrahit_1x.2F2x_series|here]] for fitting interfaces.
Line 29: Line 29:
== Photos ==
== Photos ==


<!--
<gallery>
<gallery>
File:Gmc metrahit 14a front.jpg|<small>Front</small>
File:HT410_1.jpeg|<small>Front</small>
File:Gmc metrahit 14a display.jpg|<small>Display</small>
File:HT410_2.jpeg|<small>With cords</small>
File:Gmc metrahit 14a back.jpg|<small>Back</small>
File:HT410_3.jpg|<small>Without sleeve</small>
File:Gmc metrahit 14a inside 1.jpg|<small>Back/battery cover removed</small>
File:HT410_4.jpg|<small>Back/battery cover removed</small>
File:Gmc metrahit 14a inside 2.jpg|<small>Cover removed</small>
File:HT410_5.JPG|<small>Inner cover removed</small>
File:HT410_6.jpg|<small>Package</small>
</gallery>
</gallery>
-->


== Measurement functions and ranges ==
== Measurement functions and ranges ==
Line 56: Line 55:
| rowspan="2" | ±(0,5% + 7)
| rowspan="2" | ±(0,5% + 7)
| mq V, unit V, mqflags DC
| mq V, unit V, mqflags DC
| Manual range; Accuracy with ZERO, otherwise +35 digits.  
| Manual range; accuracy with ZERO, otherwise +35 digits.  


|-
|-
Line 95: Line 94:
| 1 mV
| 1 mV
| rowspan="4" | ±(0,75% + 6)  
| rowspan="4" | ±(0,75% + 6)  
| "
| mq V, unit V, mqflags AC
|  
|  


Line 122: Line 121:
| ±(1.0% + 9)
| ±(1.0% + 9)
| mq Curr., unit A, mqflags DC
| mq Curr., unit A, mqflags DC
|  
| Manual range


|-
|-
Line 136: Line 135:
| ±(1.0% + 9)
| ±(1.0% + 9)
| "
| "
|  
| Manual range


|-
|-
Line 150: Line 149:
| ±(1,0% + 9)
| ±(1,0% + 9)
| "
| "
|  
| Manual range


|-
|-
Line 165: Line 164:
| rowspan="3" | ±(1,5% + 6)
| rowspan="3" | ±(1,5% + 6)
| mq Curr., unit A, mqflags AC
| mq Curr., unit A, mqflags AC
|
|  


|-
|-
Line 326: Line 325:
|   
|   
|  
|  
| style="background: #ff0000; "| mqflags += HOLD
| style="background: #ff0000; "| <s>mqflags += HOLD </s>
| Disabled while IR interface is active.
| Disabled while IR interface is active.
   
   
Line 334: Line 333:
|   
|   
|  
|  
| style="background: #ff0000; "| mqflags += MIN
| style="background: #ff0000; "| <s>mqflags += MIN </s>
| Disabled while IR interface is active.
| Disabled while IR interface is active.
   
   
Line 342: Line 341:
|   
|   
|  
|  
| style="background: #ff0000; "| mqflags += MAX  
| style="background: #ff0000; "| <s>mqflags += MAX</s>
| Disabled while IR interface is active.
| Disabled while IR interface is active.



Latest revision as of 22:34, 23 August 2015

HT Instruments HT410
HT410 logo.png
Status supported
Source code gmc-mh-1x-2x
Counts 3100
IEC 61010-1 CAT III 1000 V, CAT IV 600 V
Connectivity Infrared (RS232)
Measurements voltage, current, resistance, temperature, diode, continuity
Features autorange, data hold, bargraph
Website ht-instruments.com

The HT Instruments HT410 is a 3100 counts handheld digital multimeter with IR (RS232) connectivity.

It is probably a low-cost OEM version of the Rishabh 15S (see Gossen Metrawatt, Metrahit 15S) or a similar model with much worse specs, although the actual accuracy of Matthias' device seems to be better than the specs, according to the calibration certificate (!) that came with it. At least the test cords that come with it are Rishabh brand and cheaper quality than orginal Gossen Metrawatt ones, although they look the same. The same seems to be true for case and sleeve.

The IR connectivity is undocumented, possibly because no IR interface or software is available from the manufacturer. To enable sending data, press the DATA button while powering it on. See here for fitting interfaces.

Hardware

  • Battery: 9 V NEDA1604, JIS006P, IEC6F22
  • Fuse:
    • Current 300 mA: FF 1,6 A/1000V, 6,3x32 mm, 10 kA
    • Current 3A, 10A: FF 16 A/1000V, 10x38mm, 30 kA
  • TODO.

Photos

Measurement functions and ranges

Measurement function Range Resolution Accuracy sigrok result Remarks
V= 30.00 mV 10 μV ±(0,5% + 7) mq V, unit V, mqflags DC Manual range; accuracy with ZERO, otherwise +35 digits.
300.0 mV 100 μV " Manual range
3.000 V 1 mV ±(0,25% + 5) "
30.00 V 10 mV "
300.0 V 100 mV "
1000 V 1 V ±(0,35% + 5) "
V≈ 3.000 V 1 mV ±(0,75% + 6) mq V, unit V, mqflags AC
30.00 V 10 mV "
300.0 V 100 mV "
1000 V 1 V "
A= 300 µA 0.1 µA ±(1.0% + 9) mq Curr., unit A, mqflags DC Manual range
3.000 mA 1 µA ±(1.0% + 6) "
30.00 mA 10 µA ±(1.0% + 9) " Manual range
300.0 mA 100 µA ±(1,0% + 6) "
3.000 A 1 mA ±(1,0% + 9) " Manual range
10.00 A 10 mA ±(1,0% + 6) "
A≈ 3.00 mA 1 µA ±(1,5% + 6) mq Curr., unit A, mqflags AC
300.0 mA 100 µA "
10.00 A 10 mA "
Ω 30.00 Ω 10 mΩ ±(0.5% + 7) mq Res., unit Ω, mqflags - Accuracy with ZERO, otherwise +30 digits.
300.0 Ω 100 mΩ "
3.000 kΩ 1 Ω ±(0.4% + 5) "
30.00 kΩ 10 Ω "
300.0 kΩ 100 Ω "
3.000 MΩ 1 kΩ ±(0.6% + 5) "
30.00 MΩ 10 kΩ ±(2.0% + 5) "
Diode/Cont. 3.000 V– 1 mV mq V, unit V, mqflags DC,DIODE Diode and cont. are identical on this device, just without beeper for diode. Cont. beeps < 120 Ω.
Cap. F 30.00 nF 10 pF ±(1.0% + 7) mq Cap., unit F, mqflags - Accuracy with ZERO, otherwise +50 digits.
300.0 nF 100 pF "
3.000 µF 1 nF "
30.00 µF 10 nF ±(3.0% + 7) "
Hz≃ 300.0 Hz 0.1 Hz ±(0.5% + 5) mq Freq., unit Hz, mqflags AC,DC
3.000 kHz 1 Hz "
30.00 kHz 10 Hz "
100.00 kHz 100 Hz "
Duty cycle 2% - 98% 0.1 % ±5 mq Duty cycle, unit %, mqflags -
°C Pt100 –200.0 - +200.0 °C 0.1 °C ±(2 K + 9) mq Temp., unit °C, mqflags -
Pt100 +200.0 - +850.0 °C ±(1.0% + 9) "
Pt1000 –100.0 - +200.0 °C ±(2 K + 6) "
Pt1000 +200.0 - +850.0 °C ±(1.0% + 6) "
Data Hold mqflags += HOLD Disabled while IR interface is active.
MIN mqflags += MIN Disabled while IR interface is active.
MAX mqflags += MAX Disabled while IR interface is active.

The column "sigrok result" contains in short form what the driver generates for the resp. data type.

The accuracy specification is incomplete, see manual for exact specs.