]> sigrok.org Git - sigrok-cli.git/blobdiff - doc/sigrok-cli.1
Use finished output API.
[sigrok-cli.git] / doc / sigrok-cli.1
index ffbe06504b9374d4cfa50f8042e7a5aaa480f9e1..b1592bd6ba8b36c855c18fe8ceba6444a94d7842 100644 (file)
@@ -1,4 +1,4 @@
-.TH SIGROK\-CLI 1 "Feb 05, 2013"
+.TH SIGROK\-CLI 1 "May 04, 2014"
 .SH "NAME"
 sigrok\-cli \- Command-line client for the sigrok software
 .SH "SYNOPSIS"
 .SH "NAME"
 sigrok\-cli \- Command-line client for the sigrok software
 .SH "SYNOPSIS"
@@ -42,7 +42,7 @@ Some USB devices don't use a unique VendorID/ProductID combination, and thus
 need that specified as well. This also uses the \fBconn\fP option, using
 either \fBVendorID.ProductID\fP or \fBbus.address\fP:
 .sp
 need that specified as well. This also uses the \fBconn\fP option, using
 either \fBVendorID.ProductID\fP or \fBbus.address\fP:
 .sp
-.RB "  $ " "sigrok\-cli \-\-driver=nexus-osciprime:conn=04b4.8613"
+.RB "  $ " "sigrok\-cli \-\-driver=uni-t-ut61e:conn=1a86.e008"
 .TP
 .BR "\-c, \-\-config " <device>
 A colon-separated list of device options, where each option takes the form
 .TP
 .BR "\-c, \-\-config " <device>
 A colon-separated list of device options, where each option takes the form
@@ -119,33 +119,33 @@ will display 128 bits per line, in hexadecimal:
  0:ffff ffff ffff ffff ffff ffff ffff ffff
  1:ff00 ff00 ff00 ff00 ff00 ff00 ff00 ff00
 .sp
  0:ffff ffff ffff ffff ffff ffff ffff ffff
  1:ff00 ff00 ff00 ff00 ff00 ff00 ff00 ff00
 .sp
-The lines always start with the probe number (or name, if defined), followed by a colon. If no format is specified, it defaults to
+The lines always start with the channel number (or name, if defined), followed by a colon. If no format is specified, it defaults to
 .BR bits:width=64 ,
 like this:
 .sp
  0:11111111 11111111 11111111 11111111 [...]
  1:11111111 00000000 11111111 00000000 [...]
 .TP
 .BR bits:width=64 ,
 like this:
 .sp
  0:11111111 11111111 11111111 11111111 [...]
  1:11111111 00000000 11111111 00000000 [...]
 .TP
-.BR "\-p, \-\-probes " <probelist>
-A comma-separated list of probes to be used in the session.
+.BR "\-C, \-\-channels " <channellist>
+A comma-separated list of channels to be used in the session.
 .sp
 .sp
-Note that sigrok always names the probes according to how they're shown on
-the enclosure of the hardware. If your logic analyzer numbers the probes 0-15,
-that's how you must specify them with this option. An oscilloscope's probes
+Note that sigrok always names the channels according to how they're shown on
+the enclosure of the hardware. If your logic analyzer numbers the channels 0-15,
+that's how you must specify them with this option. An oscilloscope's channels
 would generally be referred to as "CH1", "CH2", and so on.
 would generally be referred to as "CH1", "CH2", and so on.
-Use the \fB\-\-show\fP option to see a list of probe names for your device.
+Use the \fB\-\-show\fP option to see a list of channel names for your device.
 .sp
 .sp
-The default is to use all the probes available on a device. You can name
-a probe like this:
+The default is to use all the channels available on a device. You can name
+a channel like this:
 .BR "1=CLK" .
 .BR "1=CLK" .
-A range of probes can also be given, in the form
+A range of channels can also be given, in the form
 .BR "1\-5" .
 .sp
 Example:
 .sp
 .RB "  $ " "sigrok\-cli \-\-driver fx2lafw \-\-samples 100"
 .br
 .BR "1\-5" .
 .sp
 Example:
 .sp
 .RB "  $ " "sigrok\-cli \-\-driver fx2lafw \-\-samples 100"
 .br
-.B "               \-\-probes 1=CLK,2\-4,7"
+.B "               \-\-channels 1=CLK,2\-4,7"
 .br
  CLK:11111111 11111111 11111111 11111111 [...]
    2:11111111 11111111 11111111 11111111 [...]
 .br
  CLK:11111111 11111111 11111111 11111111 [...]
    2:11111111 11111111 11111111 11111111 [...]
@@ -155,31 +155,21 @@ Example:
 .sp
 The comma-separated list is processed from left to right, i.e. items farther
 to the right override previous items. For example
 .sp
 The comma-separated list is processed from left to right, i.e. items farther
 to the right override previous items. For example
-.B "1=CS,1=MISO"
-will set the name of probe 1 to
+.B "1=CS,CS=MISO"
+will set the name of channel 1 to
 .BR "MISO" .
 .BR "MISO" .
-.sp
-Also, while
-.B "5=MOSI,6=MISO"
-will only select probes 5 and 6, and set their names to MISO and MOSI, the
-command line
-.B "5=MOSI,6=MISO,1\-8"
-will select probes 1\-8 (including 5 and 6, of course), but the names specified
-for probes 5 and 6 will be reset to the defaults by the
-.B "1\-8"
-probe selection.
-.TP
-.BR "\-g, \-\-probe\-group "<probe\ group>
-Specify the probe group to operate on.
+.TP
+.BR "\-g, \-\-channel\-group "<channel\ group>
+Specify the channel group to operate on.
 
 
-Some devices organize probes into groups, the settings of which can
-only be changed as a group. The list of probe groups, if any, is displayed
-with the \-\-show command.
+Some devices organize channels into groups, the settings of which can
+only be changed as a group. The list of channel groups, if any, is displayed
+with the \fB\-\-show\fP command.
 .TP
 .BR "\-t, \-\-triggers " <triggerlist>
 A comma-separated list of triggers to use, of the form
 .TP
 .BR "\-t, \-\-triggers " <triggerlist>
 A comma-separated list of triggers to use, of the form
-.BR "<probe>=<trigger>" .
-You can use the name or number of the probe, and the trigger itself is a
+.BR "<channel>=<trigger>" .
+You can use the name or number of the channel, and the trigger itself is a
 series of characters:
 .sp
 .BR "0 or 1" :
 series of characters:
 .sp
 .BR "0 or 1" :
@@ -223,28 +213,30 @@ of options, where each option takes the form
 Example:
 .sp
  $
 Example:
 .sp
  $
-.B "sigrok\-cli \-i <file.sr> \-P uart:baudrate=115200:parity_type=odd"
+.B "sigrok\-cli \-i <file.sr> "
+.br
+.B "              \-P uart:baudrate=115200:parity_type=odd"
 .sp
 The list of supported options depends entirely on the protocol decoder. Every
 protocol decoder has different options it supports.
 .sp
 Any "options" specified for a protocol decoder which are not actually
 .sp
 The list of supported options depends entirely on the protocol decoder. Every
 protocol decoder has different options it supports.
 .sp
 Any "options" specified for a protocol decoder which are not actually
-supported options, will be interpreted as being probe name/number assignments.
+supported options, will be interpreted as being channel name/number assignments.
 .sp
 Example:
 .sp
  $
 .B "sigrok\-cli \-i <file.sr>"
 .br
 .sp
 Example:
 .sp
  $
 .B "sigrok\-cli \-i <file.sr>"
 .br
-.B "              \-P spi:wordsize=9:miso=1:mosi=5:sck=3:cs=0"
+.B "              \-P spi:wordsize=9:miso=1:mosi=5:clk=3:cs=0"
 .sp
 In this example,
 .B wordsize
 is an option supported by the
 .B spi
 protocol decoder. Additionally, the user tells sigrok to decode the SPI
 .sp
 In this example,
 .B wordsize
 is an option supported by the
 .B spi
 protocol decoder. Additionally, the user tells sigrok to decode the SPI
-protocol using probe 1 as MISO signal for SPI, probe 5 as MOSI, probe 3
-as SCK, and probe 0 as CS# signal.
+protocol using channel 1 as MISO signal for SPI, channel 5 as MOSI, channel 3
+as CLK, and channel 0 as CS# signal.
 .TP
 .BR "\-S, \-\-protocol\-decoder\-stack " <stack>
 This option allows the user to specify a protocol decoder stack, i.e.
 .TP
 .BR "\-S, \-\-protocol\-decoder\-stack " <stack>
 This option allows the user to specify a protocol decoder stack, i.e.
@@ -260,13 +252,13 @@ output. In addition to the
 .B \-S
 option, all protocol decoders that are used in a stack, must also be specified
 (together with their options, if any) using the
 .B \-S
 option, all protocol decoders that are used in a stack, must also be specified
 (together with their options, if any) using the
-.B \-A
+.B \-P
 parameter.
 .sp
 Example:
 .sp
  $
 parameter.
 .sp
 Example:
 .sp
  $
-.B "sigrok\-cli \-i <file.sr> \-A i2c:sda=4:scl=7,rtc8564"
+.B "sigrok\-cli \-i <file.sr> \-P i2c:sda=4:scl=7,rtc8564"
 .br
 .B "              \-S i2c,rtc8564"
 .sp
 .br
 .B "              \-S i2c,rtc8564"
 .sp
@@ -281,7 +273,7 @@ i.e., the
 is stacked on top of the
 .BR i2c " decoder."
 .sp
 is stacked on top of the
 .BR i2c " decoder."
 .sp
-The respective protocol decoder options and probe name/number assignments
+The respective protocol decoder options and channel name/number assignments
 must be given using the
 .B \-P
 option (you cannot specify them in the
 must be given using the
 .B \-P
 option (you cannot specify them in the
@@ -296,21 +288,65 @@ display, by specifying its ID:
  $
 .B "sigrok\-cli \-i <file.sr> \-P i2c,i2cfilter,edid -A i2c"
 .sp
  $
 .B "sigrok\-cli \-i <file.sr> \-P i2c,i2cfilter,edid -A i2c"
 .sp
-If a protocol decoder has multiple annotation formats, you can also specify
-which of them to show by specifying its short description like this:
+If a protocol decoder has multiple annotations, you can also specify
+which one of them to show by specifying its short description like this:
 .sp
  $
 .B "sigrok\-cli \-i <file.sr> \-P i2c,i2cfilter,edid"
 .br
 .sp
  $
 .B "sigrok\-cli \-i <file.sr> \-P i2c,i2cfilter,edid"
 .br
-.B "              \-A i2c=rawhex"
+.B "              \-A i2c=data-read"
+.sp
+Select multiple annotations by separating them with a colon:
+.sp
+ $
+.B "sigrok\-cli \-i <file.sr> \-P i2c,i2cfilter,edid"
+.br
+.B "              \-A i2c=data-read:data-write"
 .sp
 You can also select multiple protocol decoders, with an optional selected
 .sp
 You can also select multiple protocol decoders, with an optional selected
-annotation format each, by separating them with commas:
+annotation each, by separating them with commas:
 .sp
  $
 .B "sigrok\-cli \-i <file.sr> \-P i2c,i2cfilter,edid"
 .br
 .sp
  $
 .B "sigrok\-cli \-i <file.sr> \-P i2c,i2cfilter,edid"
 .br
-.B "              \-A i2c=rawhex,edid"
+.B "              \-A i2c=data-read:data-write,edid"
+.TP
+.BR "\-M, \-\-protocol\-decoder\-meta " <pdname>
+When given, show protocol decoder meta output instead of annotations.
+The argument is the name of the decoder whose meta output to show.
+.sp
+ $
+.B "sigrok\-cli \-i <file.sr> \-M i2c"
+.sp
+Not every decoder generates meta output.
+.TP
+.BR "\-B, \-\-protocol\-decoder\-binary " <binaryspec>
+When given, decoder "raw" data of various kinds is written to stdout instead
+of annotations (this could be raw binary UART/SPI bytes, or WAV files, PCAP
+files, PNG files, or anything else; this is entirely dependent on the
+decoder and what kinds of binary output make sense for that decoder).
+.sp
+No other information is printed to stdout, so this is
+suitable for piping into other programs or saving to a file.
+.sp
+Protocol decoders that support binary output publish a list of binary
+classes, for example the UART decoder might have "TX" and "RX". To
+select TX for output, the argument to this option would be:
+.sp
+ $
+.B "sigrok\-cli \-i <file.sr> \-B uart=tx"
+.br
+.sp
+If only the protocol decoder is specified, without binary class, all classes
+are written to stdout:
+.sp
+ $
+.B "sigrok\-cli \-i <file.sr> \-B uart"
+.sp
+(this is only useful in rare cases, generally you would specify a certain
+binary class you're interested in)
+.sp
+Not every decoder generates binary output.
 .TP
 .BR "\-l, \-\-loglevel " <level>
 Set the libsigrok and libsigrokdecode loglevel. At the moment \fBsigrok-cli\fP
 .TP
 .BR "\-l, \-\-loglevel " <level>
 Set the libsigrok and libsigrokdecode loglevel. At the moment \fBsigrok-cli\fP
@@ -343,10 +379,12 @@ need a serial port specified:
  $
 .B "sigrok\-cli \-\-driver ols:conn=/dev/ttyACM0 \-\-show
 .sp
  $
 .B "sigrok\-cli \-\-driver ols:conn=/dev/ttyACM0 \-\-show
 .sp
-To view the documentation for a protocol decoder:
+This also works for protocol decoders and output modules:
 .sp
  $
 .sp
  $
-.B "sigrok\-cli \-\-protocol-decoders i2c \-\-show
+.B "sigrok\-cli \-\-protocol\-decoders i2c \-\-show
+ $
+.B "sigrok\-cli \-\-output\-format bits \-\-show
 .TP
 .B "\-\-scan"
 Scan for devices that can be detected automatically.
 .TP
 .B "\-\-scan"
 Scan for devices that can be detected automatically.
@@ -358,13 +396,9 @@ Example:
 .br
  The following devices were found:
 .br
 .br
  The following devices were found:
 .br
- Demo device with 8 probes: 0 1 2 3 4 5 6 7
-.br
- ChronoVu LA8 with 8 probes: 0 1 2 3 4 5 6 7
+ demo - Demo device with 12 channels: D0 D1 D2 D3 D4 D5 D6 D7 A0 A1 A2 A3
 .br
 .br
- ALSA: HDA ATI SB ALC270 Analog with 2 probes: Ch_0 Ch_1
-.br
- Saleae Logic with 8 probes: 0 1 2 3 4 5 6 7
+ fx2lafw:conn=3.26 - CWAV USBee SX with 8 channels: 0 1 2 3 4 5 6 7
 .sp
 However, not all devices are auto-detectable (e.g. serial port based ones).
 For those you'll have to provide a \fBconn\fP option, see above.
 .sp
 However, not all devices are auto-detectable (e.g. serial port based ones).
 For those you'll have to provide a \fBconn\fP option, see above.
@@ -374,16 +408,15 @@ For those you'll have to provide a \fBconn\fP option, see above.
 .br
  The following devices were found:
 .br
 .br
  The following devices were found:
 .br
- Digitek DT4000ZC with 1 probe: P1
+ Digitek DT4000ZC with 1 channel: P1
 .TP
 .BR "\-\-time " <ms>
 Sample for
 .B <ms>
 milliseconds, then quit.
 .sp
 .TP
 .BR "\-\-time " <ms>
 Sample for
 .B <ms>
 milliseconds, then quit.
 .sp
-You can optionally follow the number by \fBs\fP, \fBms\fP, \fBus\fP, or
-\fBns\fP to specify the time to sample in seconds, milliseconds, microseconds,
-or nanoseconds, respectively.
+You can optionally follow the number by \fBs\fP to specify the time to
+sample in seconds.
 .sp
 For example,
 .B "\-\-time 2s"
 .sp
 For example,
 .B "\-\-time 2s"
@@ -402,6 +435,11 @@ For example,
 .B "\-\-samples 3m"
 will acquire 3000000 samples.
 .TP
 .B "\-\-samples 3m"
 will acquire 3000000 samples.
 .TP
+.BR "\-\-frames " <numframes>
+Acquire
+.B <numframes>
+frames, then quit.
+.TP
 .BR "\-\-continuous"
 Sample continuously until stopped. Not all devices support this.
 .TP
 .BR "\-\-continuous"
 Sample continuously until stopped. Not all devices support this.
 .TP
@@ -422,12 +460,12 @@ Alternatively, you can also use:
 .TP
 .B "  sigrok\-cli \-\-driver fx2lafw \-\-time 3s"
 .TP
 .TP
 .B "  sigrok\-cli \-\-driver fx2lafw \-\-time 3s"
 .TP
-To capture data from the first 4 probes using the Openbench Logic Sniffer lasting 100ms at 10 MHz starting at the trigger condition
+To capture data from the first 4 channels using the Openbench Logic Sniffer lasting 100ms at 10 MHz starting at the trigger condition
 0:high, 1:rising, 2:low, 3:high, use:
 .TP
 .nf
 \fBsigrok\-cli \-\-driver ols:conn=/dev/ttyACM0 \-\-config samplerate=10m \\\fP
 0:high, 1:rising, 2:low, 3:high, use:
 .TP
 .nf
 \fBsigrok\-cli \-\-driver ols:conn=/dev/ttyACM0 \-\-config samplerate=10m \\\fP
-\fB\-\-output\-format bits \-\-probes 0\-3 \-\-wait\-trigger \\\fP
+\fB\-\-output\-format bits \-\-channels 0\-3 \-\-wait\-trigger \\\fP
 \fB\-\-triggers 0=1,1=r,2=0,3=1 \-\-time 100\fP
 .TP
 To turn on internal logging on a Lascar EL-USB series device:
 \fB\-\-triggers 0=1,1=r,2=0,3=1 \-\-time 100\fP
 .TP
 To turn on internal logging on a Lascar EL-USB series device: