]> sigrok.org Git - sigrok-cli.git/blobdiff - doc/sigrok-cli.1
cli: no need to specify stacking order if it's the same as the PD list
[sigrok-cli.git] / doc / sigrok-cli.1
index a8b1f83f96363d74931da025fc8d0e02c02862a5..58dcf1eb595db8f0643ecf98eeebd7ba01c703d0 100644 (file)
@@ -2,7 +2,7 @@
 .SH "NAME"
 sigrok\-cli \- Command-line client for the sigrok logic analyzer software
 .SH "SYNOPSIS"
 .SH "NAME"
 sigrok\-cli \- Command-line client for the sigrok logic analyzer software
 .SH "SYNOPSIS"
-.B sigrok\-cli \fR[\fB\-hVlDiIoOdptwas\fR] [\fB\-h\fR|\fB\-\-help\fR] [\fB\-V\fR|\fB\-\-version\fR] [\fB\-l\fR|\fB\-\-loglevel\fR level] [\fB\-D\fR|\fB\-\-list\-devices\fR] [\fB\-i\fR|\fB\-\-input\-file\fR filename] [\fB\-I\fR|\fB\-\-input\-format\fR format] [\fB\-o\fR|\fB\-\-output\-file\fR filename] [\fB\-O\fR|\fB\-\-output-format\fR format] [\fB\-d\fR|\fB\-\-device\fR device] [\fB\-p\fR|\fB\-\-probes\fR probelist] [\fB\-t\fR|\fB\-\-triggers\fR triggerlist] [\fB\-w\fR|\fB\-\-wait\-trigger\fR] [\fB\-a\fR|\fB\-\-protocol\-decoders\fR list] [\fB\-s\fR|\fB\-\-protocol\-decoder\-stack\fR stack] [\fB\-\-time\fR ms] [\fB\-\-samples\fR numsamples] [\fB\-\-continuous\fR]
+.B sigrok\-cli \fR[\fB\-hVlDdiIoOptwas\fR] [\fB\-h\fR|\fB\-\-help\fR] [\fB\-V\fR|\fB\-\-version\fR] [\fB\-l\fR|\fB\-\-loglevel\fR level] [\fB\-D\fR|\fB\-\-list\-devices\fR] [\fB\-d\fR|\fB\-\-device\fR device] [\fB\-i\fR|\fB\-\-input\-file\fR filename] [\fB\-I\fR|\fB\-\-input\-format\fR format] [\fB\-o\fR|\fB\-\-output\-file\fR filename] [\fB\-O\fR|\fB\-\-output-format\fR format] [\fB\-p\fR|\fB\-\-probes\fR probelist] [\fB\-t\fR|\fB\-\-triggers\fR triggerlist] [\fB\-w\fR|\fB\-\-wait\-trigger\fR] [\fB\-a\fR|\fB\-\-protocol\-decoders\fR list] [\fB\-s\fR|\fB\-\-protocol\-decoder\-stack\fR stack] [\fB\-\-time\fR ms] [\fB\-\-samples\fR numsamples] [\fB\-\-continuous\fR]
 .SH "DESCRIPTION"
 .B sigrok\-cli
 is a cross-platform command line utility for the
 .SH "DESCRIPTION"
 .B sigrok\-cli
 is a cross-platform command line utility for the
@@ -43,6 +43,29 @@ number, the more debug output will be printed. Valid loglevels are
 List all logic analyzer devices found on the system. This actively scans for
 devices (USB, serial port, and others).
 .TP
 List all logic analyzer devices found on the system. This actively scans for
 devices (USB, serial port, and others).
 .TP
+.BR "\-d, \-\-device " <device>
+The device to use for acquisition. It can be specified by ID as reported by
+.BR "\-\-list\-devices" ,
+or by the name of the driver as reported by
+.BR \-\-version .
+.sp
+A device can optionally be followed by a colon-separated list of device
+options, where each option takes the form
+.BR key=value .
+For example, to set the samplerate on the first device you might specify
+.sp
+.RB "  $ " "sigrok\-cli \-d 0:samplerate=1m"
+.sp
+Samplerate is an option common to most devices. The argument specifies the
+samplerate in Hz. You can also specify the samplerate in kHz, MHz or GHz.
+The following are all equivalent:
+.sp
+.RB "  $ " "sigrok\-cli \-\-samples 100 \-d 0:samplerate=1000000"
+.sp
+.RB "  $ " "sigrok\-cli \-\-samples 100 \-d 0:samplerate=1m"
+.sp
+.RB "  $ " "sigrok\-cli \-\-samples 100 \-d ""0:samplerate=1 MHz""
+.TP
 .BR "\-i, \-\-input\-file " <filename>
 Load input from a file instead of a hardware device. If the
 .B \-\-input\-format
 .BR "\-i, \-\-input\-file " <filename>
 Load input from a file instead of a hardware device. If the
 .B \-\-input\-format
@@ -99,29 +122,6 @@ like this:
  1:11111111 11111111 11111111 11111111 [...]
  2:11111111 00000000 11111111 00000000 [...]
 .TP
  1:11111111 11111111 11111111 11111111 [...]
  2:11111111 00000000 11111111 00000000 [...]
 .TP
-.BR "\-d, \-\-device " <device>
-The device to use for acquisition. It can be specified by ID as reported by
-.BR "\-\-list\-devices" ,
-or by the name of the driver as reported by
-.BR \-\-version .
-.sp
-A device can optionally be followed by a colon-separated list of device
-options, where each option takes the form
-.BR key=value .
-For example, to set the samplerate on the first device you might specify
-.sp
-.RB "  $ " "sigrok\-cli \-d 0:samplerate=1m"
-.sp
-Samplerate is an option common to most devices. The argument specifies the
-samplerate in Hz. You can also specify the samplerate in kHz, MHz or GHz.
-The following are all equivalent:
-.sp
-.RB "  $ " "sigrok\-cli \-\-samples 100 \-d 0:samplerate=1000000"
-.sp
-.RB "  $ " "sigrok\-cli \-\-samples 100 \-d 0:samplerate=1m"
-.sp
-.RB "  $ " "sigrok\-cli \-\-samples 100 \-d ""0:samplerate=1 MHz""
-.TP
 .BR "\-p, \-\-probes " <probelist>
 A comma-separated list of probes to be used in the session.
 .sp
 .BR "\-p, \-\-probes " <probelist>
 A comma-separated list of probes to be used in the session.
 .sp