Commit | Line | Data |
---|---|---|
c45dd41c | 1 | .TH SIGROK\-CLI 1 "March 28, 2019" |
43e5747a | 2 | .SH "NAME" |
53155b2f | 3 | sigrok\-cli \- Command-line client for the sigrok software |
43e5747a | 4 | .SH "SYNOPSIS" |
53155b2f | 5 | .B sigrok\-cli [OPTIONS] [COMMAND] |
43e5747a | 6 | .SH "DESCRIPTION" |
10d98b47 UH |
7 | \fBsigrok\-cli\fP is a cross-platform command line utility for the |
8 | \fBsigrok\fP software. | |
43e5747a | 9 | .PP |
10d98b47 UH |
10 | It cannot display graphical output, but is still sufficient to run through |
11 | the whole process of hardware initialization, acquisition, protocol decoding | |
12 | and saving the session. | |
43e5747a UH |
13 | .PP |
14 | It is useful for running on remote or embedded systems, netbooks, PDAs, | |
15 | and for various other use-cases. It can display samples on standard output or | |
16 | save them in various file formats. | |
53155b2f | 17 | .SH OPTIONS |
43e5747a | 18 | .TP |
43e5747a UH |
19 | .B "\-h, \-\-help" |
20 | Show a help text and exit. | |
21 | .TP | |
7949dca0 UH |
22 | .B "\-V, \-\-version" |
23 | Show | |
a0cfa735 | 24 | .B sigrok\-cli |
6293db8a UH |
25 | version and the versions of libraries used. |
26 | .TP | |
a0cfa735 | 27 | .B "\-L, \-\-list\-supported" |
6293db8a | 28 | Show information about supported hardware drivers, input file |
7949dca0 UH |
29 | formats, output file formats, and protocol decoders. |
30 | .TP | |
c45dd41c UH |
31 | .B "\-\-list\-supported\-wiki" |
32 | Show information about supported protocol decoders in MediaWiki syntax. | |
33 | This is generally only used by developers to easily update the list of | |
34 | supported protocol decoders in the sigrok wiki. | |
35 | .TP | |
b5ac81ad BV |
36 | \fB\-d, \-\-driver\fP <drivername> |
37 | A driver must always be selected (unless doing a global scan). Use the | |
c45dd41c | 38 | .BR "\-L " ( "\-\-list\-supported" ")" |
c1865eb5 | 39 | option to get a list of available drivers. |
53155b2f | 40 | .sp |
10d98b47 UH |
41 | Drivers can take options, in the form \fBkey=value\fP |
42 | separated by colons. | |
43 | .sp | |
44 | Drivers communicating with hardware via a serial port always need the port | |
45 | specified as the \fBconn\fP option. For example, to use the | |
46 | Openbench Logic Sniffer: | |
53155b2f | 47 | .sp |
a0cfa735 | 48 | .RB " $ " "sigrok\-cli \-\-driver=ols:conn=/dev/ttyACM0" " [...]" |
53155b2f | 49 | .sp |
10d98b47 UH |
50 | Some USB devices don't use a unique VendorID/ProductID combination, and thus |
51 | need that specified as well. This also uses the \fBconn\fP option, using | |
52 | either \fBVendorID.ProductID\fP or \fBbus.address\fP: | |
53155b2f | 53 | .sp |
a0cfa735 UH |
54 | USB \fBVendorID.ProductID\fP example: |
55 | .sp | |
56 | .RB " $ " "sigrok\-cli \-\-driver=uni\-t\-ut61e:conn=1a86.e008" " [...]" | |
57 | .sp | |
58 | USB \fBbus.address\fP example: | |
59 | .sp | |
60 | .RB " $ " "sigrok\-cli \-\-driver=uni\-t\-ut61e:conn=4.6" " [...]" | |
43e5747a | 61 | .TP |
a0cfa735 | 62 | .BR "\-c, \-\-config " <deviceoption> |
53155b2f | 63 | A colon-separated list of device options, where each option takes the form |
1b4b6a7c | 64 | .BR key=value . |
10d98b47 UH |
65 | For example, to set the samplerate to 1MHz on a device supported by the |
66 | fx2lafw driver, you might specify | |
1b4b6a7c | 67 | .sp |
a0cfa735 | 68 | .RB " $ " "sigrok\-cli \-d fx2lafw \-\-config samplerate=1m" " [...]" |
1b4b6a7c | 69 | .sp |
53155b2f BV |
70 | Samplerate is an option common to most logic analyzers. The argument specifies |
71 | the samplerate in Hz. You can also specify the samplerate in kHz, MHz or GHz. | |
1b4b6a7c UH |
72 | The following are all equivalent: |
73 | .sp | |
a0cfa735 | 74 | .RB " $ " "sigrok\-cli \-d fx2lafw \-\-config samplerate=1000000" " [...]" |
1b4b6a7c | 75 | .sp |
a0cfa735 | 76 | .RB " $ " "sigrok\-cli \-d fx2lafw \-\-config samplerate=1m" " [...]" |
1b4b6a7c | 77 | .sp |
a0cfa735 | 78 | .RB " $ " "sigrok\-cli \-d fx2lafw \-\-config \(dqsamplerate=1 MHz\(dq" " [...]" |
1b4b6a7c | 79 | .TP |
43e5747a | 80 | .BR "\-i, \-\-input\-file " <filename> |
a0cfa735 UH |
81 | Load input from a file instead of a hardware device. You can specify |
82 | "-" to use stdin as input. If the | |
43e5747a | 83 | .B \-\-input\-format |
a0cfa735 | 84 | option is not supplied, sigrok\-cli attempts to autodetect the file format of |
43e5747a | 85 | the input file. |
a0cfa735 UH |
86 | .sp |
87 | Example for loading a sigrok session file: | |
88 | .sp | |
89 | .RB " $ " "sigrok\-cli \-i example.sr" " [...]" | |
90 | .sp | |
91 | Example for loading a WAV file (autodetection of input format): | |
92 | .sp | |
93 | .RB " $ " "sigrok\-cli \-i example.wav" " [...] | |
94 | .sp | |
95 | Example for loading a VCD file from stdin (autodetection of input format): | |
96 | .sp | |
97 | .RB " $ " "cat example.vcd | sigrok\-cli \-i \-" " [...] | |
43e5747a UH |
98 | .TP |
99 | .BR "\-I, \-\-input\-format " <format> | |
100 | When loading an input file, assume it's in the specified format. If this | |
101 | option is not supplied (in addition to | |
102 | .BR \-\-input\-file ), | |
943d0c08 | 103 | sigrok-cli attempts to autodetect the file format of the input file. Use the |
a0cfa735 | 104 | .BR "\-L " ( "\-\-list\-supported" ")" |
10d98b47 UH |
105 | option to see a list of available input formats. |
106 | .sp | |
107 | The format name may optionally be followed by a colon-separated list of | |
108 | options, where each option takes the form | |
943d0c08 | 109 | .BR "key=value" . |
a0cfa735 UH |
110 | .sp |
111 | Example for loading a binary file with options: | |
112 | .sp | |
113 | .RB " $ " "sigrok\-cli \-i example.bin" | |
114 | .br | |
115 | .BR " \-I binary:numchannels=4:samplerate=1mhz" " [...]" | |
43e5747a UH |
116 | .TP |
117 | .BR "\-o, \-\-output\-file " <filename> | |
118 | Save output to a file instead of writing it to stdout. The default format | |
119 | used when saving is the sigrok session file format. This can be changed with | |
120 | the | |
76ae913d | 121 | .B \-\-output\-format |
7949dca0 | 122 | option. |
a0cfa735 UH |
123 | .sp |
124 | Example for saving data in the sigrok session format: | |
125 | .sp | |
126 | .RB " $ " "sigrok\-cli " "[...] " "\-o example.sr" | |
7949dca0 | 127 | .TP |
a0cfa735 | 128 | .BR "\-O, \-\-output\-format " <format> |
7949dca0 | 129 | Set the output format to use. Use the |
a0cfa735 | 130 | .BR "\-L " ( "\-\-list\-supported" ")" |
10d98b47 UH |
131 | option to see a list of available output formats. |
132 | .sp | |
133 | The format name may optionally be followed by a colon-separated list of | |
134 | options, where each option takes the form | |
7949dca0 UH |
135 | .BR "key=value" . |
136 | .sp | |
c1865eb5 | 137 | For example, the |
7949dca0 UH |
138 | .B bits |
139 | or | |
140 | .B hex | |
141 | formats, for an ASCII bit or ASCII hexadecimal display, can take a "width" option, specifying the number of samples (in bits) to display per line. Thus | |
a0cfa735 | 142 | .B "\-O hex:width=128" |
7949dca0 UH |
143 | will display 128 bits per line, in hexadecimal: |
144 | .sp | |
10d98b47 UH |
145 | 0:ffff ffff ffff ffff ffff ffff ffff ffff |
146 | 1:ff00 ff00 ff00 ff00 ff00 ff00 ff00 ff00 | |
7949dca0 | 147 | .sp |
029d73fe | 148 | The lines always start with the channel number (or name, if defined), followed by a colon. If no format is specified, it defaults to |
7949dca0 UH |
149 | .BR bits:width=64 , |
150 | like this: | |
151 | .sp | |
10d98b47 UH |
152 | 0:11111111 11111111 11111111 11111111 [...] |
153 | 1:11111111 00000000 11111111 00000000 [...] | |
a0cfa735 | 154 | .sp |
f5735c5e | 155 | Example for saving data in the CSV format with options: |
a0cfa735 | 156 | .sp |
f5735c5e GS |
157 | .RB " $ " "sigrok\-cli " "[...] " "\-o example.csv \-O csv:dedup:header=false" |
158 | .sp | |
159 | Notice that boolean options are \fBtrue\fP when no value gets specified. | |
43e5747a | 160 | .TP |
3dfbfbc8 | 161 | .BR "\-C, \-\-channels " <channellist> |
029d73fe | 162 | A comma-separated list of channels to be used in the session. |
43e5747a | 163 | .sp |
029d73fe | 164 | Note that sigrok always names the channels according to how they're shown on |
a0cfa735 | 165 | the enclosure of the hardware. If your logic analyzer numbers the channels 0\-15, |
029d73fe | 166 | that's how you must specify them with this option. An oscilloscope's channels |
10d98b47 | 167 | would generally be referred to as "CH1", "CH2", and so on. |
029d73fe | 168 | Use the \fB\-\-show\fP option to see a list of channel names for your device. |
53155b2f | 169 | .sp |
029d73fe UH |
170 | The default is to use all the channels available on a device. You can name |
171 | a channel like this: | |
43e5747a | 172 | .BR "1=CLK" . |
029d73fe | 173 | A range of channels can also be given, in the form |
43e5747a UH |
174 | .BR "1\-5" . |
175 | .sp | |
176 | Example: | |
177 | .sp | |
10d98b47 UH |
178 | .RB " $ " "sigrok\-cli \-\-driver fx2lafw \-\-samples 100" |
179 | .br | |
3dfbfbc8 | 180 | .B " \-\-channels 1=CLK,2\-4,7" |
43e5747a UH |
181 | .br |
182 | CLK:11111111 11111111 11111111 11111111 [...] | |
183 | 2:11111111 11111111 11111111 11111111 [...] | |
184 | 3:11111111 11111111 11111111 11111111 [...] | |
185 | 4:11111111 11111111 11111111 11111111 [...] | |
186 | 7:11111111 11111111 11111111 11111111 [...] | |
187 | .sp | |
188 | The comma-separated list is processed from left to right, i.e. items farther | |
189 | to the right override previous items. For example | |
bf836932 | 190 | .B "1=CS,CS=MISO" |
029d73fe | 191 | will set the name of channel 1 to |
43e5747a | 192 | .BR "MISO" . |
43e5747a | 193 | .TP |
ca50f4b3 | 194 | .BR "\-g, \-\-channel\-group "<channel\ group> |
a0cfa735 UH |
195 | Specify the channel group to operate on. Some devices organize channels into |
196 | groups, the settings of which can only be changed as a group. The list of | |
197 | channel groups, if any, is displayed with the \fB\-\-show\fP command. | |
198 | .sp | |
f5735c5e | 199 | Examples: |
a0cfa735 UH |
200 | .sp |
201 | .RB " $ " "sigrok\-cli \-g CH1" " [...]" | |
f5735c5e GS |
202 | .sp |
203 | .RB " $ " "sigrok\-cli \-d demo \-g Logic \-c pattern=graycode" " [...]" | |
31f9318a | 204 | .TP |
43e5747a UH |
205 | .BR "\-t, \-\-triggers " <triggerlist> |
206 | A comma-separated list of triggers to use, of the form | |
029d73fe UH |
207 | .BR "<channel>=<trigger>" . |
208 | You can use the name or number of the channel, and the trigger itself is a | |
43e5747a UH |
209 | series of characters: |
210 | .sp | |
211 | .BR "0 or 1" : | |
212 | A low or high value on the pin. | |
213 | .br | |
214 | .BR "r or f" : | |
215 | A rising or falling value on the pin. An | |
216 | .B r | |
217 | effectively corresponds to | |
218 | .BR 01 . | |
219 | .br | |
f99038b4 | 220 | .BR "e" : |
85f2ddbb | 221 | Any kind of change on a pin (either a rising or a falling edge). |
43e5747a | 222 | .sp |
10d98b47 UH |
223 | Not every device supports all of these trigger types. Use the \fB\-\-show\fP |
224 | command to see which triggers your device supports. | |
43e5747a | 225 | .TP |
a0cfa735 | 226 | .BR "\-w, \-\-wait\-trigger" |
10d98b47 UH |
227 | Don't output any sample data (even if it's actually received from the |
228 | hardware) before the trigger condition is met. In other words, do not output | |
229 | any pre-trigger data. This option is useful if you don't care about the data | |
230 | that came before the trigger (but the hardware delivers this data to sigrok | |
231 | nonetheless). | |
43e5747a | 232 | .TP |
b5ac81ad | 233 | .BR "\-P, \-\-protocol\-decoders " <list> |
85f2ddbb UH |
234 | This option allows the user to specify a comma-separated list of protocol |
235 | decoders to be used in this session. The decoders are specified by their | |
236 | ID, as shown in the | |
a0cfa735 | 237 | .BR "\-L " ( "\-\-list\-supported" ")" |
85f2ddbb UH |
238 | output. |
239 | .sp | |
240 | Example: | |
241 | .sp | |
242 | $ | |
b5ac81ad | 243 | .B "sigrok\-cli \-i <file.sr> \-P i2c" |
85f2ddbb UH |
244 | .sp |
245 | Each protocol decoder can optionally be followed by a colon-separated list | |
246 | of options, where each option takes the form | |
247 | .BR "key=value" . | |
248 | .sp | |
249 | Example: | |
250 | .sp | |
251 | $ | |
8791df07 UH |
252 | .B "sigrok\-cli \-i <file.sr> " |
253 | .br | |
254 | .B " \-P uart:baudrate=115200:parity_type=odd" | |
85f2ddbb UH |
255 | .sp |
256 | The list of supported options depends entirely on the protocol decoder. Every | |
257 | protocol decoder has different options it supports. | |
258 | .sp | |
259 | Any "options" specified for a protocol decoder which are not actually | |
029d73fe | 260 | supported options, will be interpreted as being channel name/number assignments. |
85f2ddbb UH |
261 | .sp |
262 | Example: | |
263 | .sp | |
264 | $ | |
265 | .B "sigrok\-cli \-i <file.sr>" | |
266 | .br | |
bf836932 | 267 | .B " \-P spi:wordsize=9:miso=1:mosi=5:clk=3:cs=0" |
85f2ddbb UH |
268 | .sp |
269 | In this example, | |
270 | .B wordsize | |
271 | is an option supported by the | |
272 | .B spi | |
273 | protocol decoder. Additionally, the user tells sigrok to decode the SPI | |
029d73fe | 274 | protocol using channel 1 as MISO signal for SPI, channel 5 as MOSI, channel 3 |
bf836932 | 275 | as CLK, and channel 0 as CS# signal. |
65f903f9 GS |
276 | .sp |
277 | Notice that the | |
278 | .B sigrok\-cli | |
279 | application does not support "name matching". Instead it's assumed that the | |
280 | traces in the input stream match the order of the decoder's input signals, | |
281 | or that users explicitly specify the input channel to decoder signal mapping. | |
e4b7762f GS |
282 | .br |
283 | .sp | |
284 | When multiple decoders are specified in the same | |
285 | .BR -P | |
286 | option, they will be stacked on top of each other in the specified order. | |
287 | .sp | |
288 | Example: | |
289 | .sp | |
290 | $ | |
291 | .B "sigrok\-cli \-i <file.sr> \-P i2c,eeprom24xx" | |
292 | .br | |
293 | $ | |
294 | .B "sigrok\-cli \-i <file.sr> \-P uart:baudrate=31250,midi" | |
295 | .sp | |
296 | When multiple | |
297 | .BR -P | |
298 | options are specified, each of them creates one decoder stack, which | |
299 | executes in parallel to other decoder stacks. | |
300 | .sp | |
301 | Example: | |
302 | .sp | |
303 | $ | |
304 | .B "sigrok\-cli \-i <file.sr> \-P uart:tx=D0:rx=D1 \-P timing:data=D2" | |
305 | .sp | |
85f2ddbb | 306 | .TP |
b6bd032d | 307 | .BR "\-A, \-\-protocol\-decoder\-annotations " <annotations> |
87d526cf UH |
308 | By default, all annotation output of all protocol decoders is |
309 | shown. With this option a specific decoder's annotations can be selected for | |
310 | display, by specifying the decoder ID: | |
7fb87027 BV |
311 | .sp |
312 | $ | |
a0cfa735 | 313 | .B "sigrok\-cli \-i <file.sr> \-P i2c,i2cfilter,edid \-A i2c" |
7fb87027 | 314 | .sp |
6c5438fe | 315 | If a protocol decoder has multiple annotation classes, you can also specify |
790b0261 | 316 | which one of them to show by specifying its short description like this: |
7fb87027 BV |
317 | .sp |
318 | $ | |
b5ac81ad | 319 | .B "sigrok\-cli \-i <file.sr> \-P i2c,i2cfilter,edid" |
7fb87027 | 320 | .br |
a0cfa735 | 321 | .B " \-A i2c=data\-read" |
790b0261 | 322 | .sp |
6c5438fe | 323 | Select multiple annotation classes by separating them with a colon: |
790b0261 BV |
324 | .sp |
325 | $ | |
326 | .B "sigrok\-cli \-i <file.sr> \-P i2c,i2cfilter,edid" | |
327 | .br | |
a0cfa735 | 328 | .B " \-A i2c=data\-read:data\-write" |
7fb87027 BV |
329 | .sp |
330 | You can also select multiple protocol decoders, with an optional selected | |
6c5438fe | 331 | annotation class each, by separating them with commas: |
7fb87027 BV |
332 | .sp |
333 | $ | |
b5ac81ad | 334 | .B "sigrok\-cli \-i <file.sr> \-P i2c,i2cfilter,edid" |
7fb87027 | 335 | .br |
a0cfa735 | 336 | .B " \-A i2c=data\-read:data\-write,edid" |
7fb87027 | 337 | .TP |
b0f1c540 BV |
338 | .BR "\-M, \-\-protocol\-decoder\-meta " <pdname> |
339 | When given, show protocol decoder meta output instead of annotations. | |
340 | The argument is the name of the decoder whose meta output to show. | |
341 | .sp | |
342 | $ | |
343 | .B "sigrok\-cli \-i <file.sr> \-M i2c" | |
344 | .sp | |
345 | Not every decoder generates meta output. | |
346 | .TP | |
347 | .BR "\-B, \-\-protocol\-decoder\-binary " <binaryspec> | |
348 | When given, decoder "raw" data of various kinds is written to stdout instead | |
349 | of annotations (this could be raw binary UART/SPI bytes, or WAV files, PCAP | |
350 | files, PNG files, or anything else; this is entirely dependent on the | |
351 | decoder and what kinds of binary output make sense for that decoder). | |
352 | .sp | |
353 | No other information is printed to stdout, so this is | |
354 | suitable for piping into other programs or saving to a file. | |
355 | .sp | |
356 | Protocol decoders that support binary output publish a list of binary | |
357 | classes, for example the UART decoder might have "TX" and "RX". To | |
358 | select TX for output, the argument to this option would be: | |
359 | .sp | |
360 | $ | |
361 | .B "sigrok\-cli \-i <file.sr> \-B uart=tx" | |
362 | .br | |
363 | .sp | |
364 | If only the protocol decoder is specified, without binary class, all classes | |
365 | are written to stdout: | |
366 | .sp | |
367 | $ | |
368 | .B "sigrok\-cli \-i <file.sr> \-B uart" | |
369 | .sp | |
370 | (this is only useful in rare cases, generally you would specify a certain | |
371 | binary class you're interested in) | |
372 | .sp | |
373 | Not every decoder generates binary output. | |
374 | .TP | |
8aafb57c GS |
375 | .BR "\-\-protocol\-decoder\-samplenum |
376 | When given, decoder annotations will include sample numbers, too. | |
377 | This allows consumers to receive machine readable timing information. | |
378 | .TP | |
53155b2f | 379 | .BR "\-l, \-\-loglevel " <level> |
a0cfa735 | 380 | Set the libsigrok and libsigrokdecode loglevel. At the moment \fBsigrok\-cli\fP |
10d98b47 | 381 | doesn't support setting the two loglevels independently. The higher the |
53155b2f BV |
382 | number, the more debug output will be printed. Valid loglevels are: |
383 | .sp | |
384 | \fB0\fP None | |
385 | .br | |
386 | \fB1\fP Error | |
387 | .br | |
388 | \fB2\fP Warnings | |
389 | .br | |
390 | \fB3\fP Informational | |
391 | .br | |
392 | \fB4\fP Debug | |
393 | .br | |
394 | \fB5\fP Spew | |
395 | .TP | |
396 | .B "\-\-show" | |
397 | .br | |
10d98b47 UH |
398 | Show information about the selected option. For example, to see options for a |
399 | connected fx2lafw device: | |
53155b2f BV |
400 | .sp |
401 | $ | |
402 | .B "sigrok\-cli \-\-driver fx2lafw \-\-show | |
403 | .sp | |
10d98b47 UH |
404 | In order to properly get device options for your hardware, some drivers might |
405 | need a serial port specified: | |
53155b2f BV |
406 | .sp |
407 | $ | |
408 | .B "sigrok\-cli \-\-driver ols:conn=/dev/ttyACM0 \-\-show | |
409 | .sp | |
a8b4041a | 410 | This also works for protocol decoders, input modules and output modules: |
53155b2f BV |
411 | .sp |
412 | $ | |
ad6520c4 BV |
413 | .B "sigrok\-cli \-\-protocol\-decoders i2c \-\-show |
414 | $ | |
a8b4041a BV |
415 | .B "sigrok\-cli \-\-input\-format csv \-\-show |
416 | $ | |
ad6520c4 | 417 | .B "sigrok\-cli \-\-output\-format bits \-\-show |
53155b2f | 418 | .TP |
b5ac81ad BV |
419 | .B "\-\-scan" |
420 | Scan for devices that can be detected automatically. | |
10d98b47 UH |
421 | .sp |
422 | Example: | |
423 | .sp | |
424 | $ | |
b5ac81ad | 425 | .B "sigrok\-cli \-\-scan |
10d98b47 UH |
426 | .br |
427 | The following devices were found: | |
428 | .br | |
a0cfa735 | 429 | demo \- Demo device with 12 channels: D0 D1 D2 D3 D4 D5 D6 D7 A0 A1 A2 A3 |
10d98b47 | 430 | .br |
a0cfa735 | 431 | fx2lafw:conn=3.26 \- CWAV USBee SX with 8 channels: 0 1 2 3 4 5 6 7 |
10d98b47 UH |
432 | .sp |
433 | However, not all devices are auto-detectable (e.g. serial port based ones). | |
434 | For those you'll have to provide a \fBconn\fP option, see above. | |
435 | .sp | |
436 | $ | |
a0cfa735 | 437 | .B "sigrok\-cli \-\-driver digitek\-dt4000zc:conn=/dev/ttyUSB0 \-\-scan |
10d98b47 UH |
438 | .br |
439 | The following devices were found: | |
440 | .br | |
029d73fe | 441 | Digitek DT4000ZC with 1 channel: P1 |
53155b2f | 442 | .TP |
43e5747a UH |
443 | .BR "\-\-time " <ms> |
444 | Sample for | |
445 | .B <ms> | |
10d98b47 UH |
446 | milliseconds, then quit. |
447 | .sp | |
bf836932 UH |
448 | You can optionally follow the number by \fBs\fP to specify the time to |
449 | sample in seconds. | |
10d98b47 UH |
450 | .sp |
451 | For example, | |
43e5747a UH |
452 | .B "\-\-time 2s" |
453 | will sample for two seconds. | |
454 | .TP | |
455 | .BR "\-\-samples " <numsamples> | |
456 | Acquire | |
457 | .B <numsamples> | |
458 | samples, then quit. | |
10d98b47 UH |
459 | .sp |
460 | You can optionally follow the number by \fBk\fP, \fBm\fP, or \fBg\fP to | |
461 | specify the number of samples in kilosamples, megasamples, or gigasamples, | |
462 | respectively. | |
463 | .sp | |
464 | For example, | |
465 | .B "\-\-samples 3m" | |
466 | will acquire 3000000 samples. | |
43e5747a | 467 | .TP |
66d5560b UH |
468 | .BR "\-\-frames " <numframes> |
469 | Acquire | |
470 | .B <numframes> | |
471 | frames, then quit. | |
472 | .TP | |
43e5747a UH |
473 | .BR "\-\-continuous" |
474 | Sample continuously until stopped. Not all devices support this. | |
2d73284e | 475 | .TP |
62a64762 BV |
476 | .BR "\-\-get " <variable> |
477 | Get the value of | |
478 | .B <variable> | |
479 | from the specified device and print it. | |
480 | .TP | |
2d73284e | 481 | .BR "\-\-set" |
b8656921 UH |
482 | Set one or more variables specified with the \fB\-\-config\fP option, without |
483 | doing any acquisition. | |
53155b2f | 484 | .SH EXAMPLES |
b8656921 UH |
485 | In order to get exactly 100 samples from the connected fx2lafw-supported logic |
486 | analyzer hardware, run the following command: | |
43e5747a | 487 | .TP |
53155b2f | 488 | .B " sigrok\-cli \-\-driver fx2lafw \-\-samples 100" |
43e5747a | 489 | .TP |
2d73284e | 490 | If you want to sample data for 3 seconds (3000 ms), use: |
43e5747a | 491 | .TP |
53155b2f | 492 | .B " sigrok\-cli \-\-driver fx2lafw \-\-time 3000" |
43e5747a UH |
493 | .TP |
494 | Alternatively, you can also use: | |
495 | .TP | |
53155b2f | 496 | .B " sigrok\-cli \-\-driver fx2lafw \-\-time 3s" |
43e5747a | 497 | .TP |
029d73fe | 498 | To capture data from the first 4 channels using the Openbench Logic Sniffer lasting 100ms at 10 MHz starting at the trigger condition |
53155b2f | 499 | 0:high, 1:rising, 2:low, 3:high, use: |
43e5747a | 500 | .TP |
53155b2f | 501 | .nf |
b5ac81ad | 502 | \fBsigrok\-cli \-\-driver ols:conn=/dev/ttyACM0 \-\-config samplerate=10m \\\fP |
3dfbfbc8 | 503 | \fB\-\-output\-format bits \-\-channels 0\-3 \-\-wait\-trigger \\\fP |
b5ac81ad | 504 | \fB\-\-triggers 0=1,1=r,2=0,3=1 \-\-time 100\fP |
2d73284e BV |
505 | .TP |
506 | To turn on internal logging on a Lascar EL-USB series device: | |
507 | .TP | |
508 | \fBsigrok\-cli \-\-driver lascar\-el\-usb:conn=10c4.0002 \\\fP | |
b8656921 | 509 | \fB\-\-config datalog=on \-\-set\fP |
43e5747a UH |
510 | .SH "EXIT STATUS" |
511 | .B sigrok\-cli | |
512 | exits with 0 on success, 1 on most failures. | |
513 | .SH "SEE ALSO" | |
b5ac81ad | 514 | \fBpulseview\fP(1) |
43e5747a | 515 | .SH "BUGS" |
10d98b47 UH |
516 | Please report any bugs via Bugzilla |
517 | .RB "(" http://sigrok.org/bugzilla ")" | |
518 | or on the sigrok\-devel mailing list | |
43e5747a UH |
519 | .RB "(" sigrok\-devel@lists.souceforge.net ")." |
520 | .SH "LICENSE" | |
521 | .B sigrok\-cli | |
522 | is covered by the GNU General Public License (GPL). Some portions are | |
523 | licensed under the "GPL v2 or later", some under "GPL v3 or later". | |
524 | .SH "AUTHORS" | |
525 | Please see the individual source code files. | |
526 | .PP | |
527 | This manual page was written by Uwe Hermann <uwe@hermann\-uwe.de>. | |
528 | It is licensed under the terms of the GNU GPL (version 2 or later). |