]> sigrok.org Git - sigrok-cli.git/blame - doc/sigrok-cli.1
manpage: Don't list specific output formats, mention -L.
[sigrok-cli.git] / doc / sigrok-cli.1
CommitLineData
7c765fcb 1.TH SIGROK\-CLI 1 "September 13, 2017"
43e5747a 2.SH "NAME"
53155b2f 3sigrok\-cli \- Command-line client for the sigrok software
43e5747a 4.SH "SYNOPSIS"
53155b2f 5.B sigrok\-cli [OPTIONS] [COMMAND]
43e5747a 6.SH "DESCRIPTION"
10d98b47
UH
7\fBsigrok\-cli\fP is a cross-platform command line utility for the
8\fBsigrok\fP software.
43e5747a 9.PP
10d98b47
UH
10It cannot display graphical output, but is still sufficient to run through
11the whole process of hardware initialization, acquisition, protocol decoding
12and saving the session.
43e5747a
UH
13.PP
14It is useful for running on remote or embedded systems, netbooks, PDAs,
15and for various other use-cases. It can display samples on standard output or
16save them in various file formats.
53155b2f 17.SH OPTIONS
43e5747a 18.TP
43e5747a
UH
19.B "\-h, \-\-help"
20Show a help text and exit.
21.TP
7949dca0
UH
22.B "\-V, \-\-version"
23Show
24.B sigrok-cli
6293db8a
UH
25version and the versions of libraries used.
26.TP
27.B "\-L, \-\-list-supported"
28Show information about supported hardware drivers, input file
7949dca0
UH
29formats, output file formats, and protocol decoders.
30.TP
b5ac81ad
BV
31\fB\-d, \-\-driver\fP <drivername>
32A driver must always be selected (unless doing a global scan). Use the
c1865eb5
UH
33.BR "\-L " ( "\-\-list-supported" ")"
34option to get a list of available drivers.
53155b2f 35.sp
10d98b47
UH
36Drivers can take options, in the form \fBkey=value\fP
37separated by colons.
38.sp
39Drivers communicating with hardware via a serial port always need the port
40specified as the \fBconn\fP option. For example, to use the
41Openbench Logic Sniffer:
53155b2f
BV
42.sp
43.RB " $ " "sigrok\-cli \-\-driver=ols:conn=/dev/ttyACM0"
44.sp
10d98b47
UH
45Some USB devices don't use a unique VendorID/ProductID combination, and thus
46need that specified as well. This also uses the \fBconn\fP option, using
47either \fBVendorID.ProductID\fP or \fBbus.address\fP:
53155b2f 48.sp
bf836932 49.RB " $ " "sigrok\-cli \-\-driver=uni-t-ut61e:conn=1a86.e008"
43e5747a 50.TP
b5ac81ad 51.BR "\-c, \-\-config " <device>
53155b2f 52A colon-separated list of device options, where each option takes the form
1b4b6a7c 53.BR key=value .
10d98b47
UH
54For example, to set the samplerate to 1MHz on a device supported by the
55fx2lafw driver, you might specify
1b4b6a7c 56.sp
b5ac81ad 57.RB " $ " "sigrok\-cli \-\-driver=fx2lafw \-\-config samplerate=1m"
1b4b6a7c 58.sp
53155b2f
BV
59Samplerate is an option common to most logic analyzers. The argument specifies
60the samplerate in Hz. You can also specify the samplerate in kHz, MHz or GHz.
1b4b6a7c
UH
61The following are all equivalent:
62.sp
b5ac81ad 63.RB " $ " "sigrok\-cli \-\-driver fx2lafw \-\-config samplerate=1000000"
1b4b6a7c 64.sp
b5ac81ad 65.RB " $ " "sigrok\-cli \-\-driver fx2lafw \-\-config samplerate=1m"
1b4b6a7c 66.sp
b5ac81ad 67.RB " $ " "sigrok\-cli \-\-driver fx2lafw \-\-config \(dqsamplerate=1 MHz\(dq"
1b4b6a7c 68.TP
43e5747a 69.BR "\-i, \-\-input\-file " <filename>
7949dca0 70Load input from a file instead of a hardware device. If the
43e5747a
UH
71.B \-\-input\-format
72option is not supplied, sigrok-cli attempts to autodetect the file format of
73the input file.
74.TP
75.BR "\-I, \-\-input\-format " <format>
76When loading an input file, assume it's in the specified format. If this
77option is not supplied (in addition to
78.BR \-\-input\-file ),
943d0c08 79sigrok-cli attempts to autodetect the file format of the input file. Use the
c1865eb5 80.BR "\-L " ( "\-\-list-supported" ")"
10d98b47
UH
81option to see a list of available input formats.
82.sp
83The format name may optionally be followed by a colon-separated list of
84options, where each option takes the form
943d0c08 85.BR "key=value" .
43e5747a
UH
86.TP
87.BR "\-o, \-\-output\-file " <filename>
88Save output to a file instead of writing it to stdout. The default format
89used when saving is the sigrok session file format. This can be changed with
90the
76ae913d 91.B \-\-output\-format
7949dca0
UH
92option.
93.TP
94.BR "\-O, \-\-output\-format " <formatname>
95Set the output format to use. Use the
c1865eb5 96.BR "\-L " ( "\-\-list-supported" ")"
10d98b47
UH
97option to see a list of available output formats.
98.sp
99The format name may optionally be followed by a colon-separated list of
100options, where each option takes the form
7949dca0
UH
101.BR "key=value" .
102.sp
c1865eb5 103For example, the
7949dca0
UH
104.B bits
105or
106.B hex
107formats, for an ASCII bit or ASCII hexadecimal display, can take a "width" option, specifying the number of samples (in bits) to display per line. Thus
108.B hex:width=128
109will display 128 bits per line, in hexadecimal:
110.sp
10d98b47
UH
111 0:ffff ffff ffff ffff ffff ffff ffff ffff
112 1:ff00 ff00 ff00 ff00 ff00 ff00 ff00 ff00
7949dca0 113.sp
029d73fe 114The lines always start with the channel number (or name, if defined), followed by a colon. If no format is specified, it defaults to
7949dca0
UH
115.BR bits:width=64 ,
116like this:
117.sp
10d98b47
UH
118 0:11111111 11111111 11111111 11111111 [...]
119 1:11111111 00000000 11111111 00000000 [...]
43e5747a 120.TP
3dfbfbc8 121.BR "\-C, \-\-channels " <channellist>
029d73fe 122A comma-separated list of channels to be used in the session.
43e5747a 123.sp
029d73fe
UH
124Note that sigrok always names the channels according to how they're shown on
125the enclosure of the hardware. If your logic analyzer numbers the channels 0-15,
126that's how you must specify them with this option. An oscilloscope's channels
10d98b47 127would generally be referred to as "CH1", "CH2", and so on.
029d73fe 128Use the \fB\-\-show\fP option to see a list of channel names for your device.
53155b2f 129.sp
029d73fe
UH
130The default is to use all the channels available on a device. You can name
131a channel like this:
43e5747a 132.BR "1=CLK" .
029d73fe 133A range of channels can also be given, in the form
43e5747a
UH
134.BR "1\-5" .
135.sp
136Example:
137.sp
10d98b47
UH
138.RB " $ " "sigrok\-cli \-\-driver fx2lafw \-\-samples 100"
139.br
3dfbfbc8 140.B " \-\-channels 1=CLK,2\-4,7"
43e5747a
UH
141.br
142 CLK:11111111 11111111 11111111 11111111 [...]
143 2:11111111 11111111 11111111 11111111 [...]
144 3:11111111 11111111 11111111 11111111 [...]
145 4:11111111 11111111 11111111 11111111 [...]
146 7:11111111 11111111 11111111 11111111 [...]
147.sp
148The comma-separated list is processed from left to right, i.e. items farther
149to the right override previous items. For example
bf836932 150.B "1=CS,CS=MISO"
029d73fe 151will set the name of channel 1 to
43e5747a 152.BR "MISO" .
43e5747a 153.TP
ca50f4b3
UH
154.BR "\-g, \-\-channel\-group "<channel\ group>
155Specify the channel group to operate on.
31f9318a 156
ca50f4b3
UH
157Some devices organize channels into groups, the settings of which can
158only be changed as a group. The list of channel groups, if any, is displayed
bf836932 159with the \fB\-\-show\fP command.
31f9318a 160.TP
43e5747a
UH
161.BR "\-t, \-\-triggers " <triggerlist>
162A comma-separated list of triggers to use, of the form
029d73fe
UH
163.BR "<channel>=<trigger>" .
164You can use the name or number of the channel, and the trigger itself is a
43e5747a
UH
165series of characters:
166.sp
167.BR "0 or 1" :
168A low or high value on the pin.
169.br
170.BR "r or f" :
171A rising or falling value on the pin. An
172.B r
173effectively corresponds to
174.BR 01 .
175.br
f99038b4 176.BR "e" :
85f2ddbb 177Any kind of change on a pin (either a rising or a falling edge).
43e5747a 178.sp
10d98b47
UH
179Not every device supports all of these trigger types. Use the \fB\-\-show\fP
180command to see which triggers your device supports.
43e5747a
UH
181.TP
182.BR "\-w, \-\-wait-trigger"
10d98b47
UH
183Don't output any sample data (even if it's actually received from the
184hardware) before the trigger condition is met. In other words, do not output
185any pre-trigger data. This option is useful if you don't care about the data
186that came before the trigger (but the hardware delivers this data to sigrok
187nonetheless).
43e5747a 188.TP
b5ac81ad 189.BR "\-P, \-\-protocol\-decoders " <list>
85f2ddbb
UH
190This option allows the user to specify a comma-separated list of protocol
191decoders to be used in this session. The decoders are specified by their
192ID, as shown in the
c1865eb5 193.BR "\-L " ( "\-\-list-supported" ")"
85f2ddbb
UH
194output.
195.sp
196Example:
197.sp
198 $
b5ac81ad 199.B "sigrok\-cli \-i <file.sr> \-P i2c"
85f2ddbb
UH
200.sp
201Each protocol decoder can optionally be followed by a colon-separated list
202of options, where each option takes the form
203.BR "key=value" .
204.sp
205Example:
206.sp
207 $
8791df07
UH
208.B "sigrok\-cli \-i <file.sr> "
209.br
210.B " \-P uart:baudrate=115200:parity_type=odd"
85f2ddbb
UH
211.sp
212The list of supported options depends entirely on the protocol decoder. Every
213protocol decoder has different options it supports.
214.sp
215Any "options" specified for a protocol decoder which are not actually
029d73fe 216supported options, will be interpreted as being channel name/number assignments.
85f2ddbb
UH
217.sp
218Example:
219.sp
220 $
221.B "sigrok\-cli \-i <file.sr>"
222.br
bf836932 223.B " \-P spi:wordsize=9:miso=1:mosi=5:clk=3:cs=0"
85f2ddbb
UH
224.sp
225In this example,
226.B wordsize
227is an option supported by the
228.B spi
229protocol decoder. Additionally, the user tells sigrok to decode the SPI
029d73fe 230protocol using channel 1 as MISO signal for SPI, channel 5 as MOSI, channel 3
bf836932 231as CLK, and channel 0 as CS# signal.
85f2ddbb 232.TP
b6bd032d 233.BR "\-A, \-\-protocol\-decoder\-annotations " <annotations>
7fb87027
BV
234By default, only the stack's topmost protocol decoder's annotation output is
235shown. With this option another decoder's annotation can be selected for
1a0be0e3 236display, by specifying its ID:
7fb87027
BV
237.sp
238 $
b5ac81ad 239.B "sigrok\-cli \-i <file.sr> \-P i2c,i2cfilter,edid -A i2c"
7fb87027 240.sp
790b0261
BV
241If a protocol decoder has multiple annotations, you can also specify
242which one of them to show by specifying its short description like this:
7fb87027
BV
243.sp
244 $
b5ac81ad 245.B "sigrok\-cli \-i <file.sr> \-P i2c,i2cfilter,edid"
7fb87027 246.br
790b0261
BV
247.B " \-A i2c=data-read"
248.sp
249Select multiple annotations by separating them with a colon:
250.sp
251 $
252.B "sigrok\-cli \-i <file.sr> \-P i2c,i2cfilter,edid"
253.br
254.B " \-A i2c=data-read:data-write"
7fb87027
BV
255.sp
256You can also select multiple protocol decoders, with an optional selected
790b0261 257annotation each, by separating them with commas:
7fb87027
BV
258.sp
259 $
b5ac81ad 260.B "sigrok\-cli \-i <file.sr> \-P i2c,i2cfilter,edid"
7fb87027 261.br
790b0261 262.B " \-A i2c=data-read:data-write,edid"
7fb87027 263.TP
b0f1c540
BV
264.BR "\-M, \-\-protocol\-decoder\-meta " <pdname>
265When given, show protocol decoder meta output instead of annotations.
266The argument is the name of the decoder whose meta output to show.
267.sp
268 $
269.B "sigrok\-cli \-i <file.sr> \-M i2c"
270.sp
271Not every decoder generates meta output.
272.TP
273.BR "\-B, \-\-protocol\-decoder\-binary " <binaryspec>
274When given, decoder "raw" data of various kinds is written to stdout instead
275of annotations (this could be raw binary UART/SPI bytes, or WAV files, PCAP
276files, PNG files, or anything else; this is entirely dependent on the
277decoder and what kinds of binary output make sense for that decoder).
278.sp
279No other information is printed to stdout, so this is
280suitable for piping into other programs or saving to a file.
281.sp
282Protocol decoders that support binary output publish a list of binary
283classes, for example the UART decoder might have "TX" and "RX". To
284select TX for output, the argument to this option would be:
285.sp
286 $
287.B "sigrok\-cli \-i <file.sr> \-B uart=tx"
288.br
289.sp
290If only the protocol decoder is specified, without binary class, all classes
291are written to stdout:
292.sp
293 $
294.B "sigrok\-cli \-i <file.sr> \-B uart"
295.sp
296(this is only useful in rare cases, generally you would specify a certain
297binary class you're interested in)
298.sp
299Not every decoder generates binary output.
300.TP
8aafb57c
GS
301.BR "\-\-protocol\-decoder\-samplenum
302When given, decoder annotations will include sample numbers, too.
303This allows consumers to receive machine readable timing information.
304.TP
53155b2f 305.BR "\-l, \-\-loglevel " <level>
10d98b47
UH
306Set the libsigrok and libsigrokdecode loglevel. At the moment \fBsigrok-cli\fP
307doesn't support setting the two loglevels independently. The higher the
53155b2f
BV
308number, the more debug output will be printed. Valid loglevels are:
309.sp
310\fB0\fP None
311.br
312\fB1\fP Error
313.br
314\fB2\fP Warnings
315.br
316\fB3\fP Informational
317.br
318\fB4\fP Debug
319.br
320\fB5\fP Spew
321.TP
322.B "\-\-show"
323.br
10d98b47
UH
324Show information about the selected option. For example, to see options for a
325connected fx2lafw device:
53155b2f
BV
326.sp
327 $
328.B "sigrok\-cli \-\-driver fx2lafw \-\-show
329.sp
10d98b47
UH
330In order to properly get device options for your hardware, some drivers might
331need a serial port specified:
53155b2f
BV
332.sp
333 $
334.B "sigrok\-cli \-\-driver ols:conn=/dev/ttyACM0 \-\-show
335.sp
a8b4041a 336This also works for protocol decoders, input modules and output modules:
53155b2f
BV
337.sp
338 $
ad6520c4
BV
339.B "sigrok\-cli \-\-protocol\-decoders i2c \-\-show
340 $
a8b4041a
BV
341.B "sigrok\-cli \-\-input\-format csv \-\-show
342 $
ad6520c4 343.B "sigrok\-cli \-\-output\-format bits \-\-show
53155b2f 344.TP
b5ac81ad
BV
345.B "\-\-scan"
346Scan for devices that can be detected automatically.
10d98b47
UH
347.sp
348Example:
349.sp
350 $
b5ac81ad 351.B "sigrok\-cli \-\-scan
10d98b47
UH
352.br
353 The following devices were found:
354.br
bf836932 355 demo - Demo device with 12 channels: D0 D1 D2 D3 D4 D5 D6 D7 A0 A1 A2 A3
10d98b47 356.br
bf836932 357 fx2lafw:conn=3.26 - CWAV USBee SX with 8 channels: 0 1 2 3 4 5 6 7
10d98b47
UH
358.sp
359However, not all devices are auto-detectable (e.g. serial port based ones).
360For those you'll have to provide a \fBconn\fP option, see above.
361.sp
362 $
b5ac81ad 363.B "sigrok\-cli \-\-driver digitek-dt4000zc:conn=/dev/ttyUSB0 \-\-scan
10d98b47
UH
364.br
365 The following devices were found:
366.br
029d73fe 367 Digitek DT4000ZC with 1 channel: P1
53155b2f 368.TP
43e5747a
UH
369.BR "\-\-time " <ms>
370Sample for
371.B <ms>
10d98b47
UH
372milliseconds, then quit.
373.sp
bf836932
UH
374You can optionally follow the number by \fBs\fP to specify the time to
375sample in seconds.
10d98b47
UH
376.sp
377For example,
43e5747a
UH
378.B "\-\-time 2s"
379will sample for two seconds.
380.TP
381.BR "\-\-samples " <numsamples>
382Acquire
383.B <numsamples>
384samples, then quit.
10d98b47
UH
385.sp
386You can optionally follow the number by \fBk\fP, \fBm\fP, or \fBg\fP to
387specify the number of samples in kilosamples, megasamples, or gigasamples,
388respectively.
389.sp
390For example,
391.B "\-\-samples 3m"
392will acquire 3000000 samples.
43e5747a 393.TP
66d5560b
UH
394.BR "\-\-frames " <numframes>
395Acquire
396.B <numframes>
397frames, then quit.
398.TP
43e5747a
UH
399.BR "\-\-continuous"
400Sample continuously until stopped. Not all devices support this.
2d73284e 401.TP
62a64762
BV
402.BR "\-\-get " <variable>
403Get the value of
404.B <variable>
405from the specified device and print it.
406.TP
2d73284e 407.BR "\-\-set"
b8656921
UH
408Set one or more variables specified with the \fB\-\-config\fP option, without
409doing any acquisition.
53155b2f 410.SH EXAMPLES
b8656921
UH
411In order to get exactly 100 samples from the connected fx2lafw-supported logic
412analyzer hardware, run the following command:
43e5747a 413.TP
53155b2f 414.B " sigrok\-cli \-\-driver fx2lafw \-\-samples 100"
43e5747a 415.TP
2d73284e 416If you want to sample data for 3 seconds (3000 ms), use:
43e5747a 417.TP
53155b2f 418.B " sigrok\-cli \-\-driver fx2lafw \-\-time 3000"
43e5747a
UH
419.TP
420Alternatively, you can also use:
421.TP
53155b2f 422.B " sigrok\-cli \-\-driver fx2lafw \-\-time 3s"
43e5747a 423.TP
029d73fe 424To capture data from the first 4 channels using the Openbench Logic Sniffer lasting 100ms at 10 MHz starting at the trigger condition
53155b2f 4250:high, 1:rising, 2:low, 3:high, use:
43e5747a 426.TP
53155b2f 427.nf
b5ac81ad 428\fBsigrok\-cli \-\-driver ols:conn=/dev/ttyACM0 \-\-config samplerate=10m \\\fP
3dfbfbc8 429\fB\-\-output\-format bits \-\-channels 0\-3 \-\-wait\-trigger \\\fP
b5ac81ad 430\fB\-\-triggers 0=1,1=r,2=0,3=1 \-\-time 100\fP
2d73284e
BV
431.TP
432To turn on internal logging on a Lascar EL-USB series device:
433.TP
434\fBsigrok\-cli \-\-driver lascar\-el\-usb:conn=10c4.0002 \\\fP
b8656921 435\fB\-\-config datalog=on \-\-set\fP
43e5747a
UH
436.SH "EXIT STATUS"
437.B sigrok\-cli
438exits with 0 on success, 1 on most failures.
439.SH "SEE ALSO"
b5ac81ad 440\fBpulseview\fP(1)
43e5747a 441.SH "BUGS"
10d98b47
UH
442Please report any bugs via Bugzilla
443.RB "(" http://sigrok.org/bugzilla ")"
444or on the sigrok\-devel mailing list
43e5747a
UH
445.RB "(" sigrok\-devel@lists.souceforge.net ")."
446.SH "LICENSE"
447.B sigrok\-cli
448is covered by the GNU General Public License (GPL). Some portions are
449licensed under the "GPL v2 or later", some under "GPL v3 or later".
450.SH "AUTHORS"
451Please see the individual source code files.
452.PP
453This manual page was written by Uwe Hermann <uwe@hermann\-uwe.de>.
454It is licensed under the terms of the GNU GPL (version 2 or later).