]> sigrok.org Git - sigrok-cli.git/blame - doc/sigrok-cli.1
parsers: use common library code to rename sigrok channels
[sigrok-cli.git] / doc / sigrok-cli.1
CommitLineData
c45dd41c 1.TH SIGROK\-CLI 1 "March 28, 2019"
43e5747a 2.SH "NAME"
53155b2f 3sigrok\-cli \- Command-line client for the sigrok software
43e5747a 4.SH "SYNOPSIS"
53155b2f 5.B sigrok\-cli [OPTIONS] [COMMAND]
43e5747a 6.SH "DESCRIPTION"
10d98b47
UH
7\fBsigrok\-cli\fP is a cross-platform command line utility for the
8\fBsigrok\fP software.
43e5747a 9.PP
10d98b47
UH
10It cannot display graphical output, but is still sufficient to run through
11the whole process of hardware initialization, acquisition, protocol decoding
12and saving the session.
43e5747a
UH
13.PP
14It is useful for running on remote or embedded systems, netbooks, PDAs,
15and for various other use-cases. It can display samples on standard output or
16save them in various file formats.
53155b2f 17.SH OPTIONS
43e5747a 18.TP
43e5747a
UH
19.B "\-h, \-\-help"
20Show a help text and exit.
21.TP
7949dca0
UH
22.B "\-V, \-\-version"
23Show
a0cfa735 24.B sigrok\-cli
6293db8a
UH
25version and the versions of libraries used.
26.TP
a0cfa735 27.B "\-L, \-\-list\-supported"
6293db8a 28Show information about supported hardware drivers, input file
7949dca0
UH
29formats, output file formats, and protocol decoders.
30.TP
c45dd41c
UH
31.B "\-\-list\-supported\-wiki"
32Show information about supported protocol decoders in MediaWiki syntax.
33This is generally only used by developers to easily update the list of
34supported protocol decoders in the sigrok wiki.
35.TP
b5ac81ad 36\fB\-d, \-\-driver\fP <drivername>
77525a84
GS
37Unless doing a global scan, users typically select one of the available
38drivers. This can speedup program start, and can avoid false matches for
39ambiguous configurations. Selecting a driver also allows to pass more
40driver specific options. Use the
c45dd41c 41.BR "\-L " ( "\-\-list\-supported" ")"
c1865eb5 42option to get a list of available drivers.
53155b2f 43.sp
10d98b47
UH
44Drivers can take options, in the form \fBkey=value\fP
45separated by colons.
46.sp
47Drivers communicating with hardware via a serial port always need the port
48specified as the \fBconn\fP option. For example, to use the
49Openbench Logic Sniffer:
53155b2f 50.sp
a0cfa735 51.RB " $ " "sigrok\-cli \-\-driver=ols:conn=/dev/ttyACM0" " [...]"
53155b2f 52.sp
10d98b47 53Some USB devices don't use a unique VendorID/ProductID combination, and thus
d6469268
GS
54need that specified as well. Notice that colons are used to separate the
55driver name from the \fBconn\fP option, thus colons cannot be used within the
56\fBconn\fP option's argument. To select a specific USB device, use either
57\fBVendorID.ProductID\fP or \fBbus.address\fP:
53155b2f 58.sp
a0cfa735
UH
59USB \fBVendorID.ProductID\fP example:
60.sp
61.RB " $ " "sigrok\-cli \-\-driver=uni\-t\-ut61e:conn=1a86.e008" " [...]"
62.sp
63USB \fBbus.address\fP example:
64.sp
65.RB " $ " "sigrok\-cli \-\-driver=uni\-t\-ut61e:conn=4.6" " [...]"
43e5747a 66.TP
b20ea789
GS
67.B "\-D, \-\-dont\-scan"
68Do not automatically scan for device drivers in the absence of a
69.BR "\-d " ( "\-\-driver" )
70specification.
71.TP
a0cfa735 72.BR "\-c, \-\-config " <deviceoption>
53155b2f 73A colon-separated list of device options, where each option takes the form
1b4b6a7c 74.BR key=value .
0e2f95c4
GS
75Multiple occurances of the
76.B \-\-config
77option are supported.
78The first item in the list of options can take the form
79.B channel_group=<name>
80which would override the
81.B \-\-channel\-group
82specification for this list of options. Other option lists in other
83.B \-\-config
84occurances are not affected by this list's channel group name.
85.sp
10d98b47
UH
86For example, to set the samplerate to 1MHz on a device supported by the
87fx2lafw driver, you might specify
1b4b6a7c 88.sp
a0cfa735 89.RB " $ " "sigrok\-cli \-d fx2lafw \-\-config samplerate=1m" " [...]"
1b4b6a7c 90.sp
53155b2f
BV
91Samplerate is an option common to most logic analyzers. The argument specifies
92the samplerate in Hz. You can also specify the samplerate in kHz, MHz or GHz.
1b4b6a7c
UH
93The following are all equivalent:
94.sp
a0cfa735 95.RB " $ " "sigrok\-cli \-d fx2lafw \-\-config samplerate=1000000" " [...]"
1b4b6a7c 96.sp
a0cfa735 97.RB " $ " "sigrok\-cli \-d fx2lafw \-\-config samplerate=1m" " [...]"
1b4b6a7c 98.sp
a0cfa735 99.RB " $ " "sigrok\-cli \-d fx2lafw \-\-config \(dqsamplerate=1 MHz\(dq" " [...]"
0e2f95c4
GS
100.sp
101These examples specify options within a channel group.
102The first two are equivalent.
103.sp
104.RB " $ " "sigrok\-cli \-d demo \-\-channel\-group Logic \-\-config pattern=random [...]"
105.sp
106.RB " $ " "sigrok\-cli \-d demo \-\-config channel_group=Logic:pattern=random [...]"
107.sp
108.RB " $ " "sigrok\-cli \-d demo \-\-config samplerate=1m \-\-config channel_group=Logic:pattern=random [...]"
1b4b6a7c 109.TP
43e5747a 110.BR "\-i, \-\-input\-file " <filename>
a0cfa735
UH
111Load input from a file instead of a hardware device. You can specify
112"-" to use stdin as input. If the
43e5747a 113.B \-\-input\-format
a0cfa735 114option is not supplied, sigrok\-cli attempts to autodetect the file format of
43e5747a 115the input file.
a0cfa735
UH
116.sp
117Example for loading a sigrok session file:
118.sp
119.RB " $ " "sigrok\-cli \-i example.sr" " [...]"
120.sp
121Example for loading a WAV file (autodetection of input format):
122.sp
123.RB " $ " "sigrok\-cli \-i example.wav" " [...]
124.sp
125Example for loading a VCD file from stdin (autodetection of input format):
126.sp
127.RB " $ " "cat example.vcd | sigrok\-cli \-i \-" " [...]
43e5747a
UH
128.TP
129.BR "\-I, \-\-input\-format " <format>
130When loading an input file, assume it's in the specified format. If this
131option is not supplied (in addition to
132.BR \-\-input\-file ),
943d0c08 133sigrok-cli attempts to autodetect the file format of the input file. Use the
a0cfa735 134.BR "\-L " ( "\-\-list\-supported" ")"
10d98b47
UH
135option to see a list of available input formats.
136.sp
137The format name may optionally be followed by a colon-separated list of
138options, where each option takes the form
943d0c08 139.BR "key=value" .
a0cfa735
UH
140.sp
141Example for loading a binary file with options:
142.sp
143.RB " $ " "sigrok\-cli \-i example.bin"
144.br
145.BR " \-I binary:numchannels=4:samplerate=1mhz" " [...]"
43e5747a
UH
146.TP
147.BR "\-o, \-\-output\-file " <filename>
148Save output to a file instead of writing it to stdout. The default format
149used when saving is the sigrok session file format. This can be changed with
150the
76ae913d 151.B \-\-output\-format
7949dca0 152option.
a0cfa735
UH
153.sp
154Example for saving data in the sigrok session format:
155.sp
156.RB " $ " "sigrok\-cli " "[...] " "\-o example.sr"
7949dca0 157.TP
a0cfa735 158.BR "\-O, \-\-output\-format " <format>
7949dca0 159Set the output format to use. Use the
a0cfa735 160.BR "\-L " ( "\-\-list\-supported" ")"
10d98b47
UH
161option to see a list of available output formats.
162.sp
163The format name may optionally be followed by a colon-separated list of
164options, where each option takes the form
7949dca0
UH
165.BR "key=value" .
166.sp
c1865eb5 167For example, the
7949dca0
UH
168.B bits
169or
170.B hex
171formats, for an ASCII bit or ASCII hexadecimal display, can take a "width" option, specifying the number of samples (in bits) to display per line. Thus
a0cfa735 172.B "\-O hex:width=128"
7949dca0
UH
173will display 128 bits per line, in hexadecimal:
174.sp
10d98b47
UH
175 0:ffff ffff ffff ffff ffff ffff ffff ffff
176 1:ff00 ff00 ff00 ff00 ff00 ff00 ff00 ff00
7949dca0 177.sp
029d73fe 178The lines always start with the channel number (or name, if defined), followed by a colon. If no format is specified, it defaults to
7949dca0
UH
179.BR bits:width=64 ,
180like this:
181.sp
10d98b47
UH
182 0:11111111 11111111 11111111 11111111 [...]
183 1:11111111 00000000 11111111 00000000 [...]
a0cfa735 184.sp
f5735c5e 185Example for saving data in the CSV format with options:
a0cfa735 186.sp
f5735c5e
GS
187.RB " $ " "sigrok\-cli " "[...] " "\-o example.csv \-O csv:dedup:header=false"
188.sp
189Notice that boolean options are \fBtrue\fP when no value gets specified.
43e5747a 190.TP
3dfbfbc8 191.BR "\-C, \-\-channels " <channellist>
029d73fe 192A comma-separated list of channels to be used in the session.
43e5747a 193.sp
029d73fe 194Note that sigrok always names the channels according to how they're shown on
a0cfa735 195the enclosure of the hardware. If your logic analyzer numbers the channels 0\-15,
029d73fe 196that's how you must specify them with this option. An oscilloscope's channels
10d98b47 197would generally be referred to as "CH1", "CH2", and so on.
029d73fe 198Use the \fB\-\-show\fP option to see a list of channel names for your device.
53155b2f 199.sp
029d73fe
UH
200The default is to use all the channels available on a device. You can name
201a channel like this:
43e5747a 202.BR "1=CLK" .
029d73fe 203A range of channels can also be given, in the form
43e5747a
UH
204.BR "1\-5" .
205.sp
206Example:
207.sp
10d98b47
UH
208.RB " $ " "sigrok\-cli \-\-driver fx2lafw \-\-samples 100"
209.br
3dfbfbc8 210.B " \-\-channels 1=CLK,2\-4,7"
43e5747a
UH
211.br
212 CLK:11111111 11111111 11111111 11111111 [...]
213 2:11111111 11111111 11111111 11111111 [...]
214 3:11111111 11111111 11111111 11111111 [...]
215 4:11111111 11111111 11111111 11111111 [...]
216 7:11111111 11111111 11111111 11111111 [...]
217.sp
218The comma-separated list is processed from left to right, i.e. items farther
219to the right override previous items. For example
bf836932 220.B "1=CS,CS=MISO"
029d73fe 221will set the name of channel 1 to
43e5747a 222.BR "MISO" .
43e5747a 223.TP
ca50f4b3 224.BR "\-g, \-\-channel\-group "<channel\ group>
a0cfa735
UH
225Specify the channel group to operate on. Some devices organize channels into
226groups, the settings of which can only be changed as a group. The list of
227channel groups, if any, is displayed with the \fB\-\-show\fP command.
228.sp
f5735c5e 229Examples:
a0cfa735
UH
230.sp
231.RB " $ " "sigrok\-cli \-g CH1" " [...]"
f5735c5e
GS
232.sp
233.RB " $ " "sigrok\-cli \-d demo \-g Logic \-c pattern=graycode" " [...]"
0e2f95c4
GS
234.sp
235Channel group specifications in
236.B \-\-get
237or
238.B \-\-config
239options take precedence over channel group names in
240.B \-\-channel\-group
241so that a single
242.B sigrok\-cli
243invocation can support the query or manipulation of multiple device options
244which reside in different channel groups.
31f9318a 245.TP
43e5747a
UH
246.BR "\-t, \-\-triggers " <triggerlist>
247A comma-separated list of triggers to use, of the form
029d73fe
UH
248.BR "<channel>=<trigger>" .
249You can use the name or number of the channel, and the trigger itself is a
43e5747a
UH
250series of characters:
251.sp
252.BR "0 or 1" :
253A low or high value on the pin.
254.br
255.BR "r or f" :
256A rising or falling value on the pin. An
257.B r
258effectively corresponds to
259.BR 01 .
260.br
f99038b4 261.BR "e" :
85f2ddbb 262Any kind of change on a pin (either a rising or a falling edge).
43e5747a 263.sp
10d98b47
UH
264Not every device supports all of these trigger types. Use the \fB\-\-show\fP
265command to see which triggers your device supports.
43e5747a 266.TP
a0cfa735 267.BR "\-w, \-\-wait\-trigger"
10d98b47
UH
268Don't output any sample data (even if it's actually received from the
269hardware) before the trigger condition is met. In other words, do not output
270any pre-trigger data. This option is useful if you don't care about the data
271that came before the trigger (but the hardware delivers this data to sigrok
272nonetheless).
43e5747a 273.TP
b5ac81ad 274.BR "\-P, \-\-protocol\-decoders " <list>
85f2ddbb
UH
275This option allows the user to specify a comma-separated list of protocol
276decoders to be used in this session. The decoders are specified by their
277ID, as shown in the
a0cfa735 278.BR "\-L " ( "\-\-list\-supported" ")"
85f2ddbb
UH
279output.
280.sp
281Example:
282.sp
283 $
b5ac81ad 284.B "sigrok\-cli \-i <file.sr> \-P i2c"
85f2ddbb
UH
285.sp
286Each protocol decoder can optionally be followed by a colon-separated list
287of options, where each option takes the form
288.BR "key=value" .
289.sp
290Example:
291.sp
292 $
8791df07
UH
293.B "sigrok\-cli \-i <file.sr> "
294.br
525f4814 295.B " \-P uart:baudrate=115200:parity=odd"
85f2ddbb
UH
296.sp
297The list of supported options depends entirely on the protocol decoder. Every
298protocol decoder has different options it supports.
299.sp
300Any "options" specified for a protocol decoder which are not actually
029d73fe 301supported options, will be interpreted as being channel name/number assignments.
85f2ddbb
UH
302.sp
303Example:
304.sp
305 $
306.B "sigrok\-cli \-i <file.sr>"
307.br
bf836932 308.B " \-P spi:wordsize=9:miso=1:mosi=5:clk=3:cs=0"
85f2ddbb
UH
309.sp
310In this example,
311.B wordsize
312is an option supported by the
313.B spi
314protocol decoder. Additionally, the user tells sigrok to decode the SPI
029d73fe 315protocol using channel 1 as MISO signal for SPI, channel 5 as MOSI, channel 3
bf836932 316as CLK, and channel 0 as CS# signal.
65f903f9
GS
317.sp
318Notice that the
319.B sigrok\-cli
320application does not support "name matching". Instead it's assumed that the
321traces in the input stream match the order of the decoder's input signals,
322or that users explicitly specify the input channel to decoder signal mapping.
e4b7762f
GS
323.br
324.sp
325When multiple decoders are specified in the same
326.BR -P
327option, they will be stacked on top of each other in the specified order.
328.sp
329Example:
330.sp
331 $
332.B "sigrok\-cli \-i <file.sr> \-P i2c,eeprom24xx"
333.br
334 $
335.B "sigrok\-cli \-i <file.sr> \-P uart:baudrate=31250,midi"
336.sp
337When multiple
338.BR -P
339options are specified, each of them creates one decoder stack, which
340executes in parallel to other decoder stacks.
341.sp
342Example:
343.sp
344 $
345.B "sigrok\-cli \-i <file.sr> \-P uart:tx=D0:rx=D1 \-P timing:data=D2"
346.sp
85f2ddbb 347.TP
b6bd032d 348.BR "\-A, \-\-protocol\-decoder\-annotations " <annotations>
87d526cf
UH
349By default, all annotation output of all protocol decoders is
350shown. With this option a specific decoder's annotations can be selected for
351display, by specifying the decoder ID:
7fb87027
BV
352.sp
353 $
a0cfa735 354.B "sigrok\-cli \-i <file.sr> \-P i2c,i2cfilter,edid \-A i2c"
7fb87027 355.sp
6c5438fe 356If a protocol decoder has multiple annotation classes, you can also specify
790b0261 357which one of them to show by specifying its short description like this:
7fb87027
BV
358.sp
359 $
b5ac81ad 360.B "sigrok\-cli \-i <file.sr> \-P i2c,i2cfilter,edid"
7fb87027 361.br
a0cfa735 362.B " \-A i2c=data\-read"
790b0261 363.sp
6c5438fe 364Select multiple annotation classes by separating them with a colon:
790b0261
BV
365.sp
366 $
367.B "sigrok\-cli \-i <file.sr> \-P i2c,i2cfilter,edid"
368.br
a0cfa735 369.B " \-A i2c=data\-read:data\-write"
7fb87027 370.sp
b7360ee6
GS
371Annotation row names will resolve to their respective list of classes.
372Row and class names can be used in combination. When names are ambiguous
373then class names take precedence.
374.sp
375 $
376.B "sigrok\-cli \-i <file.sr> \-P i2c"
377.br
378.B " \-A i2c=addr\-data:warnings"
379.sp
380You can also select multiple protocol decoders, with optionally selected
381annotation classes each, by separating them with commas:
7fb87027
BV
382.sp
383 $
b5ac81ad 384.B "sigrok\-cli \-i <file.sr> \-P i2c,i2cfilter,edid"
7fb87027 385.br
a0cfa735 386.B " \-A i2c=data\-read:data\-write,edid"
7fb87027 387.TP
b0f1c540
BV
388.BR "\-M, \-\-protocol\-decoder\-meta " <pdname>
389When given, show protocol decoder meta output instead of annotations.
390The argument is the name of the decoder whose meta output to show.
391.sp
392 $
393.B "sigrok\-cli \-i <file.sr> \-M i2c"
394.sp
395Not every decoder generates meta output.
396.TP
397.BR "\-B, \-\-protocol\-decoder\-binary " <binaryspec>
398When given, decoder "raw" data of various kinds is written to stdout instead
399of annotations (this could be raw binary UART/SPI bytes, or WAV files, PCAP
400files, PNG files, or anything else; this is entirely dependent on the
401decoder and what kinds of binary output make sense for that decoder).
402.sp
403No other information is printed to stdout, so this is
404suitable for piping into other programs or saving to a file.
405.sp
406Protocol decoders that support binary output publish a list of binary
407classes, for example the UART decoder might have "TX" and "RX". To
408select TX for output, the argument to this option would be:
409.sp
410 $
411.B "sigrok\-cli \-i <file.sr> \-B uart=tx"
412.br
413.sp
414If only the protocol decoder is specified, without binary class, all classes
415are written to stdout:
416.sp
417 $
418.B "sigrok\-cli \-i <file.sr> \-B uart"
419.sp
420(this is only useful in rare cases, generally you would specify a certain
421binary class you're interested in)
422.sp
423Not every decoder generates binary output.
424.TP
8aafb57c
GS
425.BR "\-\-protocol\-decoder\-samplenum
426When given, decoder annotations will include sample numbers, too.
427This allows consumers to receive machine readable timing information.
428.TP
53155b2f 429.BR "\-l, \-\-loglevel " <level>
a0cfa735 430Set the libsigrok and libsigrokdecode loglevel. At the moment \fBsigrok\-cli\fP
10d98b47 431doesn't support setting the two loglevels independently. The higher the
53155b2f
BV
432number, the more debug output will be printed. Valid loglevels are:
433.sp
434\fB0\fP None
435.br
436\fB1\fP Error
437.br
438\fB2\fP Warnings
439.br
440\fB3\fP Informational
441.br
442\fB4\fP Debug
443.br
444\fB5\fP Spew
445.TP
446.B "\-\-show"
447.br
10d98b47
UH
448Show information about the selected option. For example, to see options for a
449connected fx2lafw device:
53155b2f
BV
450.sp
451 $
452.B "sigrok\-cli \-\-driver fx2lafw \-\-show
453.sp
10d98b47
UH
454In order to properly get device options for your hardware, some drivers might
455need a serial port specified:
53155b2f
BV
456.sp
457 $
458.B "sigrok\-cli \-\-driver ols:conn=/dev/ttyACM0 \-\-show
459.sp
a8b4041a 460This also works for protocol decoders, input modules and output modules:
53155b2f
BV
461.sp
462 $
ad6520c4
BV
463.B "sigrok\-cli \-\-protocol\-decoders i2c \-\-show
464 $
a8b4041a
BV
465.B "sigrok\-cli \-\-input\-format csv \-\-show
466 $
ad6520c4 467.B "sigrok\-cli \-\-output\-format bits \-\-show
b45ae06e
GS
468.sp
469This also works for input files, including optional input format specifications:
470.sp
471 $
472.B "sigrok\-cli \-\-input\-file <file.sr> \-\-show
473 $
474.B "sigrok\-cli \-\-input\-file <file.vcd> \-\-input\-format vcd \-\-show
53155b2f 475.TP
b5ac81ad
BV
476.B "\-\-scan"
477Scan for devices that can be detected automatically.
10d98b47
UH
478.sp
479Example:
480.sp
481 $
b5ac81ad 482.B "sigrok\-cli \-\-scan
10d98b47
UH
483.br
484 The following devices were found:
485.br
a0cfa735 486 demo \- Demo device with 12 channels: D0 D1 D2 D3 D4 D5 D6 D7 A0 A1 A2 A3
10d98b47 487.br
a0cfa735 488 fx2lafw:conn=3.26 \- CWAV USBee SX with 8 channels: 0 1 2 3 4 5 6 7
10d98b47
UH
489.sp
490However, not all devices are auto-detectable (e.g. serial port based ones).
491For those you'll have to provide a \fBconn\fP option, see above.
492.sp
493 $
a0cfa735 494.B "sigrok\-cli \-\-driver digitek\-dt4000zc:conn=/dev/ttyUSB0 \-\-scan
10d98b47
UH
495.br
496 The following devices were found:
497.br
029d73fe 498 Digitek DT4000ZC with 1 channel: P1
53155b2f 499.TP
43e5747a
UH
500.BR "\-\-time " <ms>
501Sample for
502.B <ms>
10d98b47
UH
503milliseconds, then quit.
504.sp
bf836932
UH
505You can optionally follow the number by \fBs\fP to specify the time to
506sample in seconds.
10d98b47
UH
507.sp
508For example,
43e5747a
UH
509.B "\-\-time 2s"
510will sample for two seconds.
511.TP
512.BR "\-\-samples " <numsamples>
513Acquire
514.B <numsamples>
515samples, then quit.
10d98b47
UH
516.sp
517You can optionally follow the number by \fBk\fP, \fBm\fP, or \fBg\fP to
518specify the number of samples in kilosamples, megasamples, or gigasamples,
519respectively.
520.sp
521For example,
522.B "\-\-samples 3m"
523will acquire 3000000 samples.
43e5747a 524.TP
66d5560b
UH
525.BR "\-\-frames " <numframes>
526Acquire
527.B <numframes>
528frames, then quit.
529.TP
43e5747a
UH
530.BR "\-\-continuous"
531Sample continuously until stopped. Not all devices support this.
2d73284e 532.TP
62a64762
BV
533.BR "\-\-get " <variable>
534Get the value of
535.B <variable>
536from the specified device and print it.
0e2f95c4
GS
537Multiple variable names can be specified and get separated by colon.
538The list of variable names optionally can be preceeded by
539.B "channel_group=<name>"
540which would override the
541.B \-\-channel\-group
542specification.
543Multiple
544.B \-\-get
545occurances are supported in a single
546.B sigrok\-cli
547invocation.
548.sp
549 $
550.B sigrok\-cli \-d demo \-\-get samplerate:averaging \-\-get channel_group=Logic:pattern
62a64762 551.TP
2d73284e 552.BR "\-\-set"
b8656921
UH
553Set one or more variables specified with the \fB\-\-config\fP option, without
554doing any acquisition.
53155b2f 555.SH EXAMPLES
b8656921
UH
556In order to get exactly 100 samples from the connected fx2lafw-supported logic
557analyzer hardware, run the following command:
43e5747a 558.TP
53155b2f 559.B " sigrok\-cli \-\-driver fx2lafw \-\-samples 100"
43e5747a 560.TP
2d73284e 561If you want to sample data for 3 seconds (3000 ms), use:
43e5747a 562.TP
53155b2f 563.B " sigrok\-cli \-\-driver fx2lafw \-\-time 3000"
43e5747a
UH
564.TP
565Alternatively, you can also use:
566.TP
53155b2f 567.B " sigrok\-cli \-\-driver fx2lafw \-\-time 3s"
43e5747a 568.TP
029d73fe 569To capture data from the first 4 channels using the Openbench Logic Sniffer lasting 100ms at 10 MHz starting at the trigger condition
53155b2f 5700:high, 1:rising, 2:low, 3:high, use:
43e5747a 571.TP
53155b2f 572.nf
b5ac81ad 573\fBsigrok\-cli \-\-driver ols:conn=/dev/ttyACM0 \-\-config samplerate=10m \\\fP
3dfbfbc8 574\fB\-\-output\-format bits \-\-channels 0\-3 \-\-wait\-trigger \\\fP
b5ac81ad 575\fB\-\-triggers 0=1,1=r,2=0,3=1 \-\-time 100\fP
2d73284e
BV
576.TP
577To turn on internal logging on a Lascar EL-USB series device:
578.TP
579\fBsigrok\-cli \-\-driver lascar\-el\-usb:conn=10c4.0002 \\\fP
b8656921 580\fB\-\-config datalog=on \-\-set\fP
43e5747a
UH
581.SH "EXIT STATUS"
582.B sigrok\-cli
583exits with 0 on success, 1 on most failures.
584.SH "SEE ALSO"
b5ac81ad 585\fBpulseview\fP(1)
43e5747a 586.SH "BUGS"
10d98b47
UH
587Please report any bugs via Bugzilla
588.RB "(" http://sigrok.org/bugzilla ")"
589or on the sigrok\-devel mailing list
43e5747a
UH
590.RB "(" sigrok\-devel@lists.souceforge.net ")."
591.SH "LICENSE"
592.B sigrok\-cli
593is covered by the GNU General Public License (GPL). Some portions are
594licensed under the "GPL v2 or later", some under "GPL v3 or later".
595.SH "AUTHORS"
596Please see the individual source code files.
597.PP
598This manual page was written by Uwe Hermann <uwe@hermann\-uwe.de>.
599It is licensed under the terms of the GNU GPL (version 2 or later).