SR_CONF_CONN,
};
-static const uint32_t devopts[] = {
+static const uint32_t drvopts[] = {
SR_CONF_THERMOMETER,
+};
+
+static const uint32_t devopts[] = {
SR_CONF_CONTINUOUS,
SR_CONF_LIMIT_SAMPLES | SR_CONF_GET | SR_CONF_SET,
SR_CONF_DATA_SOURCE | SR_CONF_GET | SR_CONF_SET | SR_CONF_LIST,
static int config_list(uint32_t key, GVariant **data, const struct sr_dev_inst *sdi,
const struct sr_channel_group *cg)
{
- (void)sdi;
- (void)cg;
-
switch (key) {
case SR_CONF_SCAN_OPTIONS:
- *data = g_variant_new_fixed_array(G_VARIANT_TYPE_UINT32,
- scanopts, ARRAY_SIZE(scanopts), sizeof(uint32_t));
- break;
case SR_CONF_DEVICE_OPTIONS:
- *data = g_variant_new_fixed_array(G_VARIANT_TYPE_UINT32,
- devopts, ARRAY_SIZE(devopts), sizeof(uint32_t));
- break;
+ return STD_CONFIG_LIST(key, data, sdi, cg, scanopts, drvopts, devopts);
case SR_CONF_DATA_SOURCE:
*data = g_variant_new_strv(data_sources, ARRAY_SIZE(data_sources));
break;
.cleanup = std_cleanup,
.scan = scan,
.dev_list = std_dev_list,
- .dev_clear = NULL,
+ .dev_clear = std_dev_clear,
.config_get = config_get,
.config_set = config_set,
.config_list = config_list,