]> sigrok.org Git - libsigrok.git/blobdiff - src/hardware/teleinfo/protocol.c
scpi-pps: don't break SCPI devices when scanning for HP-IB devices
[libsigrok.git] / src / hardware / teleinfo / protocol.c
index 54be6252a75e340b535b48972d983fa60b666413..1938664d03c26dbf962ecda6a7034db6a6bca68b 100644 (file)
@@ -70,6 +70,7 @@ static void teleinfo_send_value(struct sr_dev_inst *sdi, const char *channel_nam
        if (!ch || !ch->enabled)
                return;
 
+       /* Note: digits/spec_digits is actually really 0 for this device! */
        sr_analog_init(&analog, &encoding, &meaning, &spec, 0);
        analog.meaning->channels = g_slist_append(analog.meaning->channels, ch);
        analog.num_samples = 1;
@@ -95,35 +96,34 @@ static void teleinfo_handle_measurement(struct sr_dev_inst *sdi,
                return;
        }
 
-       if (!strcmp(label, "ADCO")) {
+       if (!strcmp(label, "ADCO"))
                sr_sw_limits_update_samples_read(&devc->sw_limits, 1);
-       } else if (!strcmp(label, "BASE")) {
-               teleinfo_send_value(sdi, "BASE", v, SR_MQ_POWER, SR_UNIT_WATT_HOUR);
-       } else if (!strcmp(label, "HCHP")) {
-               teleinfo_send_value(sdi, "HP"  , v, SR_MQ_POWER, SR_UNIT_WATT_HOUR);
-       } else if (!strcmp(label, "HCHC")) {
-               teleinfo_send_value(sdi, "HC"  , v, SR_MQ_POWER, SR_UNIT_WATT_HOUR);
-       } else if (!strcmp(label, "EJPHN")) {
-               teleinfo_send_value(sdi, "HN"  , v, SR_MQ_POWER, SR_UNIT_WATT_HOUR);
-       } else if (!strcmp(label, "EJPHPM")) {
-               teleinfo_send_value(sdi, "HPM" , v, SR_MQ_POWER, SR_UNIT_WATT_HOUR);
-       } else if (!strcmp(label, "BBRHPJB")) {
-               teleinfo_send_value(sdi, "HPJB", v, SR_MQ_POWER, SR_UNIT_WATT_HOUR);
-       } else if (!strcmp(label, "BBRHPJW")) {
-               teleinfo_send_value(sdi, "HPJW", v, SR_MQ_POWER, SR_UNIT_WATT_HOUR);
-       } else if (!strcmp(label, "BBRHPJR")) {
-               teleinfo_send_value(sdi, "HPJR", v, SR_MQ_POWER, SR_UNIT_WATT_HOUR);
-       } else if (!strcmp(label, "BBRHCJB")) {
-               teleinfo_send_value(sdi, "HCJB", v, SR_MQ_POWER, SR_UNIT_WATT_HOUR);
-       } else if (!strcmp(label, "BBRHCJW")) {
-               teleinfo_send_value(sdi, "HCJW", v, SR_MQ_POWER, SR_UNIT_WATT_HOUR);
-       } else if (!strcmp(label, "BBRHCJR")) {
-               teleinfo_send_value(sdi, "HCJR", v, SR_MQ_POWER, SR_UNIT_WATT_HOUR);
-       } else if (!strcmp(label, "IINST")) {
+       else if (!strcmp(label, "BASE"))
+               teleinfo_send_value(sdi, "BASE", v, SR_MQ_ENERGY, SR_UNIT_WATT_HOUR);
+       else if (!strcmp(label, "HCHP"))
+               teleinfo_send_value(sdi, "HP"  , v, SR_MQ_ENERGY, SR_UNIT_WATT_HOUR);
+       else if (!strcmp(label, "HCHC"))
+               teleinfo_send_value(sdi, "HC"  , v, SR_MQ_ENERGY, SR_UNIT_WATT_HOUR);
+       else if (!strcmp(label, "EJPHN"))
+               teleinfo_send_value(sdi, "HN"  , v, SR_MQ_ENERGY, SR_UNIT_WATT_HOUR);
+       else if (!strcmp(label, "EJPHPM"))
+               teleinfo_send_value(sdi, "HPM" , v, SR_MQ_ENERGY, SR_UNIT_WATT_HOUR);
+       else if (!strcmp(label, "BBRHPJB"))
+               teleinfo_send_value(sdi, "HPJB", v, SR_MQ_ENERGY, SR_UNIT_WATT_HOUR);
+       else if (!strcmp(label, "BBRHPJW"))
+               teleinfo_send_value(sdi, "HPJW", v, SR_MQ_ENERGY, SR_UNIT_WATT_HOUR);
+       else if (!strcmp(label, "BBRHPJR"))
+               teleinfo_send_value(sdi, "HPJR", v, SR_MQ_ENERGY, SR_UNIT_WATT_HOUR);
+       else if (!strcmp(label, "BBRHCJB"))
+               teleinfo_send_value(sdi, "HCJB", v, SR_MQ_ENERGY, SR_UNIT_WATT_HOUR);
+       else if (!strcmp(label, "BBRHCJW"))
+               teleinfo_send_value(sdi, "HCJW", v, SR_MQ_ENERGY, SR_UNIT_WATT_HOUR);
+       else if (!strcmp(label, "BBRHCJR"))
+               teleinfo_send_value(sdi, "HCJR", v, SR_MQ_ENERGY, SR_UNIT_WATT_HOUR);
+       else if (!strcmp(label, "IINST"))
                teleinfo_send_value(sdi, "IINST", v, SR_MQ_CURRENT, SR_UNIT_AMPERE);
-       } else if (!strcmp(label, "PAPP")) {
+       else if (!strcmp(label, "PAPP"))
                teleinfo_send_value(sdi, "PAPP", v, SR_MQ_POWER, SR_UNIT_VOLT_AMPERE);
-       }
 }
 
 static gboolean teleinfo_parse_group(struct sr_dev_inst *sdi,
@@ -220,7 +220,7 @@ SR_PRIV int teleinfo_receive_data(int fd, int revents, void *cb_data)
        }
 
        if (sr_sw_limits_check(&devc->sw_limits))
-               sdi->driver->dev_acquisition_stop(sdi);
+               sr_dev_acquisition_stop(sdi);
 
        return TRUE;
 }