]> sigrok.org Git - libsigrok.git/blobdiff - README.devices
Drop left-overs of the removed alsa driver.
[libsigrok.git] / README.devices
index c51e1d7227754de6f2e0f0b474820f3550334d53..e4416402b0b8bb3b7991b44f2af73ab75e4d4998 100644 (file)
@@ -10,7 +10,7 @@ Firmware
 --------
 
 Some devices supported by libsigrok need a firmware to be uploaded every time
-the device is connected to the PC (usually via USB), before it can be used. 
+the device is connected to the PC (usually via USB), before it can be used.
 
 The default location where libsigrok expects the firmware files is:
 
@@ -50,12 +50,12 @@ The following drivers/devices require a firmware upload upon connection:
 The following drivers/devices do not need any firmware upload:
 
  - agilent-dmm
- - alsa
  - appa-55ii
+ - brymen-bm86x
  - brymen-dmm
  - cem-dt-885x
  - center-3xx (including all subdrivers)
- - chronovu-la8
+ - chronovu-la
  - colead-slm
  - demo
  - fluke-dmm
@@ -115,9 +115,9 @@ The following drivers/devices require a serial port specification:
 
 The following drivers/devices do not require a serial port specification:
 
- - alsa
  - asix-sigma
- - chronovu-la8
+ - brymen-bm86x
+ - chronovu-la
  - demo
  - fx2lafw
  - hantek-dso
@@ -287,14 +287,24 @@ a short list for convenience:
  - BBC Goertz Metrawatt M2110: Briefly press the "Start/Reset" button on the
    interface panel on top.
  - Digitek DT4000ZC: Briefly press the "RS232" button.
- - Gossen Metrawatt Metrahit devices: Power on the device with the "DATA"
-   button pressed. Additionally, Metrahit 2x devices must be configured for
-   interface "RS232".
+ - Gossen Metrawatt Metrahit 1x/2x devices, driver gmc-mh-1x-2x-rs232:
+   - Power on the device with the "DATA" button pressed.
+   - Metrahit 2x devices must be configured for the respective interface type.
+ - Gossen Metrawatt Metrahit 2x devices, driver gmc-mh-2x-bd232:
+   - 'BD232' interface:
+      The multimeter must be configured for the respective interface type.
+   - 'SI232-II' interface ("PC Mode"):
+      The multimeter must be configured for interface type 'BD232' (all),
+      'SI232 online' (28-29S) or 'SI232 store' (22-26x). The interface must
+      be configured to the same baud rate as the host (default 9600).
+      Multimeter and interface must be configured to the same address.
  - Norma DM950: If the interface doesn't work (e.g. USB-RS232 converter), power
    on the device with "FUNC" pressed (to power the interface from the DMM).
  - PCE PCE-DM32: Briefly press the "RS232" button.
  - RadioShack 22-812: Press and hold "SELECT" and "RANGE" together.
  - TekPower TP4000ZC: Briefly press the "RS232" button.
+ - Tenma 72-7750: Briefly press the "RS232C" button.
+ - UNI-T UT60G: Briefly press the "RS232C" button.
  - UNI-T UT61B/C/D: Press the "REL/RS232/USB" button for roughly 1 second.
  - UNI-T UT325: Briefly press the "SEND" button (as per manual). However, it
    appears that in practice you don't have to press the button (at least on
@@ -304,20 +314,6 @@ a short list for convenience:
  - Voltcraft VC-830: Press the "REL/PC" button for roughly 2 seconds.
 
 
-ALSA driver
------------
-
-The 'alsa' driver can be used to sample analog data using a PC's soundcard.
-I.e. the sound card can act as a simple oscilloscope (with some limitations)
-using commercial or DIY "sound card scope probe" cables.
-
-Since ALSA is a Linux-specific sound system, this driver will inherently
-only compile and work on Linux.
-
-We might write additional drivers to make a similar functionality available
-on other OSes at some point.
-
-
 Link Instruments MSO-19
 -----------------------
 
@@ -328,20 +324,19 @@ system). Thus, this driver can currently only compile and work on Linux.
 We plan to fix this though, so that it'll work on all other OSes, too.
 
 
-ChronoVu LA8 USB VID/PIDs
--------------------------
+ChronoVu LA8/LA16 USB VID/PIDs
+------------------------------
 
-The ChronoVu LA8 logic analyzer is available in two revisions. Previously,
-the LA8 shipped with a USB VID/PID of 0403:6001, which is the standard ID
+The ChronoVu LA8/LA16 logic analyzer is available in two revisions. Previously,
+the device shipped with a USB VID/PID of 0403:6001, which is the standard ID
 for FTDI FT232 USB chips.
 
-Since this made it hard to distinguish the LA8 from any other device
+Since this made it hard to distinguish the LA8/LA16 from any other device
 with this FTDI chip connected to the PC, the vendor later shipped the
-LA8 with a USB VID/PID of 0403:8867.
+device with a USB VID/PID of 0403:8867.
 
-The 'chronovu-la8' driver in libsigrok supports both VID/PID pairs and
-automatically finds devices with either VID/PID pair. However, currently
-the driver will assume any device with VID/PID 0403:6001 is a ChronoVu LA8.
+The 'chronovu-la' driver in libsigrok supports both VID/PID pairs and
+automatically finds devices with either VID/PID pair.
 
 
 OLS