Some devices supported by libsigrok need a firmware to be uploaded every time
-the device is connected to the PC (usually via USB), before it can be used.
+the device is connected to the PC (usually via USB), before it can be used.
The default location where libsigrok expects the firmware files is:
The following drivers/devices do not need any firmware upload:
- agilent-dmm
- - alsa
- appa-55ii
+ - brymen-bm86x
- brymen-dmm
- cem-dt-885x
- center-3xx (including all subdrivers)
- - chronovu-la8
+ - chronovu-la
- colead-slm
- demo
- fluke-dmm
The following drivers/devices do not require a serial port specification:
- - alsa
- asix-sigma
- - chronovu-la8
+ - brymen-bm86x
+ - chronovu-la
- demo
- fx2lafw
- hantek-dso
- BBC Goertz Metrawatt M2110: Briefly press the "Start/Reset" button on the
interface panel on top.
- Digitek DT4000ZC: Briefly press the "RS232" button.
- - Gossen Metrawatt Metrahit devices: Power on the device with the "DATA"
- button pressed. Additionally, Metrahit 2x devices must be configured for
- interface "RS232".
+ - Gossen Metrawatt Metrahit 1x/2x devices, driver gmc-mh-1x-2x-rs232:
+ - Power on the device with the "DATA" button pressed.
+ - Metrahit 2x devices must be configured for the respective interface type.
+ - Gossen Metrawatt Metrahit 2x devices, driver gmc-mh-2x-bd232:
+ - 'BD232' interface:
+ The multimeter must be configured for the respective interface type.
+ - 'SI232-II' interface ("PC Mode"):
+ The multimeter must be configured for interface type 'BD232' (all),
+ 'SI232 online' (28-29S) or 'SI232 store' (22-26x). The interface must
+ be configured to the same baud rate as the host (default 9600).
+ Multimeter and interface must be configured to the same address.
- Norma DM950: If the interface doesn't work (e.g. USB-RS232 converter), power
on the device with "FUNC" pressed (to power the interface from the DMM).
- PCE PCE-DM32: Briefly press the "RS232" button.
- Voltcraft VC-830: Press the "REL/PC" button for roughly 2 seconds.
-ALSA driver
------------
-
-The 'alsa' driver can be used to sample analog data using a PC's soundcard.
-I.e. the sound card can act as a simple oscilloscope (with some limitations)
-using commercial or DIY "sound card scope probe" cables.
-
-Since ALSA is a Linux-specific sound system, this driver will inherently
-only compile and work on Linux.
-
-We might write additional drivers to make a similar functionality available
-on other OSes at some point.
-
-
Link Instruments MSO-19
-----------------------
We plan to fix this though, so that it'll work on all other OSes, too.
-ChronoVu LA8 USB VID/PIDs
--------------------------
+ChronoVu LA8/LA16 USB VID/PIDs
+------------------------------
-The ChronoVu LA8 logic analyzer is available in two revisions. Previously,
-the LA8 shipped with a USB VID/PID of 0403:6001, which is the standard ID
+The ChronoVu LA8/LA16 logic analyzer is available in two revisions. Previously,
+the device shipped with a USB VID/PID of 0403:6001, which is the standard ID
for FTDI FT232 USB chips.
-Since this made it hard to distinguish the LA8 from any other device
+Since this made it hard to distinguish the LA8/LA16 from any other device
with this FTDI chip connected to the PC, the vendor later shipped the
-LA8 with a USB VID/PID of 0403:8867.
+device with a USB VID/PID of 0403:8867.
-The 'chronovu-la8' driver in libsigrok supports both VID/PID pairs and
-automatically finds devices with either VID/PID pair. However, currently
-the driver will assume any device with VID/PID 0403:6001 is a ChronoVu LA8.
+The 'chronovu-la' driver in libsigrok supports both VID/PID pairs and
+automatically finds devices with either VID/PID pair.
OLS