]> sigrok.org Git - libsigrok.git/blobdiff - README.devices
Drop left-overs of the removed alsa driver.
[libsigrok.git] / README.devices
index 368d2d7911c329749c5f2c3cd36a1bbf39a7a92c..e4416402b0b8bb3b7991b44f2af73ab75e4d4998 100644 (file)
@@ -10,7 +10,7 @@ Firmware
 --------
 
 Some devices supported by libsigrok need a firmware to be uploaded every time
-the device is connected to the PC (usually via USB), before it can be used. 
+the device is connected to the PC (usually via USB), before it can be used.
 
 The default location where libsigrok expects the firmware files is:
 
@@ -50,27 +50,30 @@ The following drivers/devices require a firmware upload upon connection:
 The following drivers/devices do not need any firmware upload:
 
  - agilent-dmm
- - alsa
+ - appa-55ii
+ - brymen-bm86x
  - brymen-dmm
  - cem-dt-885x
- - center-3xx
- - chronovu-la8
+ - center-3xx (including all subdrivers)
+ - chronovu-la
  - colead-slm
  - demo
  - fluke-dmm
+ - gmc-mh-1x-2x
+ - hameg-hmo
  - ikalogic-scanalogic2
  - ikalogic-scanaplus
  - kecheng-kc-330b
  - lascar-el-usb
  - link-mso19
- - mic-985xx
+ - mic-985xx (including all subdrivers)
  - norma-dmm
  - openbench-logic-sniffer
  - rigol-ds
- - serial-dmm
+ - serial-dmm (including all subdrivers)
  - teleinfo
  - tondaj-sl-814
- - uni-t-dmm
+ - uni-t-dmm (including all subdrivers)
  - uni-t-ut32x
  - victor-dmm
  - zeroplus-logic-cube
@@ -93,24 +96,28 @@ Example:
 The following drivers/devices require a serial port specification:
 
  - agilent-dmm
+ - appa-55ii
  - brymen-dmm
  - cem-dt-885x
- - center-3xx
+ - center-3xx (including all subdrivers)
  - colead-slm
  - fluke-dmm
+ - gmc-mh-1x-2x
+ - hameg-hmo
  - link-mso19
- - mic-985xx
+ - mic-985xx (including all subdrivers)
  - norma-dmm
  - openbench-logic-sniffer
- - serial-dmm
+ - rigol-ds (for RS232; not required for USBTMC or TCP)
+ - serial-dmm (including all subdrivers)
  - teleinfo
  - tondaj-sl-814
 
 The following drivers/devices do not require a serial port specification:
 
- - alsa
  - asix-sigma
- - chronovu-la8
+ - brymen-bm86x
+ - chronovu-la
  - demo
  - fx2lafw
  - hantek-dso
@@ -118,14 +125,27 @@ The following drivers/devices do not require a serial port specification:
  - ikalogic-scanaplus
  - kecheng-kc-330b
  - lascar-el-usb
- - rigol-ds
+ - rigol-ds (USBTMC or TCP)
  - saleae-logic16
- - uni-t-dmm
+ - uni-t-dmm (including all subdrivers)
  - uni-t-ut32x
  - victor-dmm
  - zeroplus-logic-cube
 
 
+Specifiying serial port parameters
+----------------------------------
+
+Every serial device's driver has default serial port parameters like baud
+rate, number of data bits, stop bits and handshake status. If a device requires
+different parameters, pass them as option "serialcomm" with the driver name.
+See libsigrok docs for function serial_set_paramstr() for complete specs.
+
+Example:
+
+ $ sigrok-cli --driver <somedriver>:conn=<someconn>:serialcomm=9600/7n1/dtr=1
+
+
 Permissions of serial port based devices
 ----------------------------------------
 
@@ -264,35 +284,36 @@ unless a certain action has been performed by the user beforehand. This is
 usually mentioned in the vendor manual of the respective device, but here's
 a short list for convenience:
 
+ - BBC Goertz Metrawatt M2110: Briefly press the "Start/Reset" button on the
+   interface panel on top.
  - Digitek DT4000ZC: Briefly press the "RS232" button.
+ - Gossen Metrawatt Metrahit 1x/2x devices, driver gmc-mh-1x-2x-rs232:
+   - Power on the device with the "DATA" button pressed.
+   - Metrahit 2x devices must be configured for the respective interface type.
+ - Gossen Metrawatt Metrahit 2x devices, driver gmc-mh-2x-bd232:
+   - 'BD232' interface:
+      The multimeter must be configured for the respective interface type.
+   - 'SI232-II' interface ("PC Mode"):
+      The multimeter must be configured for interface type 'BD232' (all),
+      'SI232 online' (28-29S) or 'SI232 store' (22-26x). The interface must
+      be configured to the same baud rate as the host (default 9600).
+      Multimeter and interface must be configured to the same address.
+ - Norma DM950: If the interface doesn't work (e.g. USB-RS232 converter), power
+   on the device with "FUNC" pressed (to power the interface from the DMM).
  - PCE PCE-DM32: Briefly press the "RS232" button.
  - RadioShack 22-812: Press and hold "SELECT" and "RANGE" together.
  - TekPower TP4000ZC: Briefly press the "RS232" button.
- - UNI-T UT61C: Press the "REL/RS232/USB" button for roughly 1 second.
- - UNI-T UT61D: Press the "REL/RS232/USB" button for roughly 1 second.
+ - Tenma 72-7750: Briefly press the "RS232C" button.
+ - UNI-T UT60G: Briefly press the "RS232C" button.
+ - UNI-T UT61B/C/D: Press the "REL/RS232/USB" button for roughly 1 second.
  - UNI-T UT325: Briefly press the "SEND" button (as per manual). However, it
    appears that in practice you don't have to press the button (at least on
    some versions of the device), simply connect the device via USB.
- - V&A VA18B: Keep the "Hz/DUTY" key pressed while powering on the device.
- - Victor 70C: Press the "REL/RS232" button for roughly 1 second.
- - Victor 86C: Press the "REL/RS232" button for roughly 1 second.
+ - V&A VA18B/VA40B: Keep the "Hz/DUTY" key pressed while powering on the DMM.
+ - Victor 70C/86C: Press the "REL/RS232" button for roughly 1 second.
  - Voltcraft VC-830: Press the "REL/PC" button for roughly 2 seconds.
 
 
-ALSA driver
------------
-
-The 'alsa' driver can be used to sample analog data using a PC's soundcard.
-I.e. the sound card can act as a simple oscilloscope (with some limitations)
-using commercial or DIY "sound card scope probe" cables.
-
-Since ALSA is a Linux-specific sound system, this driver will inherently
-only compile and work on Linux.
-
-We might write additional drivers to make a similar functionality available
-on other OSes at some point.
-
-
 Link Instruments MSO-19
 -----------------------
 
@@ -303,20 +324,19 @@ system). Thus, this driver can currently only compile and work on Linux.
 We plan to fix this though, so that it'll work on all other OSes, too.
 
 
-ChronoVu LA8 USB VID/PIDs
--------------------------
+ChronoVu LA8/LA16 USB VID/PIDs
+------------------------------
 
-The ChronoVu LA8 logic analyzer is available in two revisions. Previously,
-the LA8 shipped with a USB VID/PID of 0403:6001, which is the standard ID
+The ChronoVu LA8/LA16 logic analyzer is available in two revisions. Previously,
+the device shipped with a USB VID/PID of 0403:6001, which is the standard ID
 for FTDI FT232 USB chips.
 
-Since this made it hard to distinguish the LA8 from any other device
+Since this made it hard to distinguish the LA8/LA16 from any other device
 with this FTDI chip connected to the PC, the vendor later shipped the
-LA8 with a USB VID/PID of 0403:8867.
+device with a USB VID/PID of 0403:8867.
 
-The 'chronovu-la8' driver in libsigrok supports both VID/PID pairs and
-automatically finds devices with either VID/PID pair. However, currently
-the driver will assume any device with VID/PID 0403:6001 is a ChronoVu LA8.
+The 'chronovu-la' driver in libsigrok supports both VID/PID pairs and
+automatically finds devices with either VID/PID pair.
 
 
 OLS