]> sigrok.org Git - libsigrok.git/blobdiff - README.devices
lecroy-xstream: Remove header read (PR #33)
[libsigrok.git] / README.devices
index 9ab254a13b00c8ff44beba2f2bbcd1daf115e45a..a7e50a395302d9b5a6e9d351a138ea54dc5b8e0b 100644 (file)
@@ -107,6 +107,7 @@ The following drivers/devices do not need any firmware upload:
  - maynuo-m97
  - mic-985xx (including all subdrivers)
  - motech-lps-30x
+ - mooshimeter-dmm
  - norma-dmm
  - openbench-logic-sniffer
  - pce-322a
@@ -149,6 +150,28 @@ Example:
  $ sigrok-cli --driver <somedriver>:conn=hid/cp2110 ...
  $ sigrok-cli --driver <somedriver>:conn=bt/rfcomm/01-23-45-67-89-ab ...
 
+Formal syntax for serial communication:
+
+ - COM ports (RS232, USB CDC):
+   conn=<com-port>
+ - USB HID cables:
+   conn=hid[/<chip>]
+   conn=hid[/<chip>]/usb=<bus>.<dev>[.<if>]
+   conn=hid[/<chip>]/raw=<path>
+   conn=hid[/<chip>]/sn=<serno>
+   chip can be: ch9325, cp2110
+   path may contain slashes
+   path and serno are "greedy" (span to the end of the spec)
+ - Bluetooth Classic and Bluetooth Low Energy (BLE):
+   conn=bt/<conn>/<addr>
+   conn can be: rfcomm, ble122, nrf51, cc254x
+   addr can be "dense" or separated, bt/cc254x/0123456789ab or
+     bt/rfcomm/11-22-33-44-55-66 or bt/ble122/88:6b:12:34:56:78
+     (note that colons may not be available when the conn= spec is taken
+     from a string that separates fields by colon, e.g. in the "--driver
+     <name>:conn=<spec>" example, that is why the dense form and the use
+     of dashes for separation are supported)
+
 The following drivers/devices require a serial port specification. Some of
 the drivers implement a default for the connection. Some of the drivers
 can auto-detect USB connected devices.
@@ -193,11 +216,10 @@ The following drivers/devices do not require a serial port specification:
  - saleae-logic16
  - sysclk-lwla
  - uni-t-dmm (all non -ser subdrivers)
- - victor-dmm
  - yokogawa-dlm (USBTMC or TCP)
  - zeroplus-logic-cube
 
-Beyond strict serial communication over COM ports (e.g. /dev/ttyUSB0), the
+Beyond strict serial communication over COM ports (discussed above), the
 conn= property can also address specific USB devices, as well as specify TCP
 or VXI communication parameters. See these examples:
 
@@ -379,6 +401,9 @@ a short list for convenience:
  - Brymen BM257s: Press HOLD during power-on.
  - Digitek DT4000ZC: Briefly press the "RS232" button.
  - EEVBlog 121GW: Hold "1ms PEAK" until the "BT" indicator is shown.
+ - ES51919 based LCR meters (DER EE DE-5000, PeakTech 2170, UNI-T UT612):
+   Press the button with the "RS232" or "USB" or "PC link" label (usually
+   the "up" cursor button).
  - Gossen Metrawatt Metrahit 1x/2x devices, driver gmc-mh-1x-2x-rs232:
    - Power on the device with the "DATA" button pressed.
    - Metrahit 2x devices must be configured for the respective interface type.
@@ -451,3 +476,74 @@ Example:
 
  $ sigrok-cli --driver ols:conn=/dev/ttyACM0 ...
 
+
+Mooshimeter
+-----------
+
+The Mooshim Engineering Mooshimeter is controlled via Bluetooth Low Energy
+(sometimes called Bluetooth 4.0), as such it requires a supported Bluetooth
+interface available. The 'conn' option is required and must contain the
+Bluetooth MAC address of the meter.
+
+Example:
+
+  $ sigrok-cli --driver mooshimeter-dmm:conn=12-34-56-78-9A-BC ...
+
+Since the Mooshimeter has no physical interface on the meter itself, the
+channel configuration is set with the 'channel_config' option. The format
+of this option is 'CH1,CH2' where each channel configuration has the form
+'MODE:RANGE:ANALYSIS', with later parts being optional. In addition for
+CLI compatibility, the ',' in the channels can also be a '/' and the ':' in
+the individual configuration can be a ';'.
+
+Available channel 1 modes:
+
+  - Current, A: Current in amps
+  - Temperature, T, K: Internal meter temperature in Kelvin
+  - Resistance, Ohm, W: Resistance in ohms
+  - Diode, D: Diode voltage
+  - Aux, LV: Auxiliary (W input) low voltage sensor (1.2V max)
+
+Available channel 2 modes:
+
+  - Voltage, V: Voltage
+  - Temperature, T, K: Internal meter temperature in Kelvin
+  - Resistance, Ohm, W: Resistance in ohms
+  - Diode, D: Diode voltage
+  - Aux, LV: Auxiliary (W input) low voltage sensor (1.2V max)
+
+Only one channel can use the shared inputs at a time (e.g. if CH1 is measuring
+resistance, CH2 cannot measure low voltage). Temperature is excepted from
+this, so the meter can measure internal temperature and low voltage at the
+same time.
+
+Additionally, the meter can calculate the real power of both channels. This
+generally only makes sense when CH1 is set to current and CH2 is set to a
+voltage and so it is disabled by default. It must be enabled by enabling the
+'P' channel (the third channel).
+
+The range of the channel specification sets the maximum input for that channel
+and is rounded up to the next value the meter itself supports. For example,
+specifying 50 for the voltage will result in the actual maximum of 60.
+Specifying 61 would result in 600. If omitted, sigrok will perform
+auto-ranging of the channel by selecting the next greater value than the
+latest maximum.
+
+The analysis option sets how the meter reports its internal sampling buffer
+to sigrok:
+
+ - Mean, DC: The default is a simple arithmetic mean of the sample buffer
+ - RMS, AC: The root mean square of the sample buffer
+ - Buf, Buffer, Samples: Report the entire sample buffer to sigrok. This
+   results in packets that contain all the samples in the buffer instead
+   of a single output value.
+
+The size of the sample buffer is set with the 'avg_samples' option, while
+the sampling rate is set with the 'samplerate' option. So the update rate
+is avg_samples/samplerate. Both are rounded up to the next supported value
+by the meter.
+
+Example:
+
+  $ sigrok-cli -c channel_config="Aux;0.1/T" --driver mooshimeter-dmm...
+  $ sigrok-cli -c channel_config="A;;AC/V;;AC" --driver mooshimeter-dmm...