]> sigrok.org Git - libsigrok.git/blobdiff - README.devices
brymen-bm86x: actual driver implementation
[libsigrok.git] / README.devices
index c51e1d7227754de6f2e0f0b474820f3550334d53..30f8e474d7eb2e9130f9f1f3fb9fb3a8b3d07597 100644 (file)
@@ -10,7 +10,7 @@ Firmware
 --------
 
 Some devices supported by libsigrok need a firmware to be uploaded every time
-the device is connected to the PC (usually via USB), before it can be used. 
+the device is connected to the PC (usually via USB), before it can be used.
 
 The default location where libsigrok expects the firmware files is:
 
@@ -52,6 +52,7 @@ The following drivers/devices do not need any firmware upload:
  - agilent-dmm
  - alsa
  - appa-55ii
+ - brymen-bm86x
  - brymen-dmm
  - cem-dt-885x
  - center-3xx (including all subdrivers)
@@ -117,6 +118,7 @@ The following drivers/devices do not require a serial port specification:
 
  - alsa
  - asix-sigma
+ - brymen-bm86x
  - chronovu-la8
  - demo
  - fx2lafw
@@ -287,14 +289,24 @@ a short list for convenience:
  - BBC Goertz Metrawatt M2110: Briefly press the "Start/Reset" button on the
    interface panel on top.
  - Digitek DT4000ZC: Briefly press the "RS232" button.
- - Gossen Metrawatt Metrahit devices: Power on the device with the "DATA"
-   button pressed. Additionally, Metrahit 2x devices must be configured for
-   interface "RS232".
+ - Gossen Metrawatt Metrahit 1x/2x devices, driver gmc-mh-1x-2x-rs232:
+   - Power on the device with the "DATA" button pressed.
+   - Metrahit 2x devices must be configured for the respective interface type.
+ - Gossen Metrawatt Metrahit 2x devices, driver gmc-mh-2x-bd232:
+   - 'BD232' interface:
+      The multimeter must be configured for the respective interface type.
+   - 'SI232-II' interface ("PC Mode"):
+      The multimeter must be configured for interface type 'BD232' (all),
+      'SI232 online' (28-29S) or 'SI232 store' (22-26x). The interface must
+      be configured to the same baud rate as the host (default 9600).
+      Multimeter and interface must be configured to the same address.
  - Norma DM950: If the interface doesn't work (e.g. USB-RS232 converter), power
    on the device with "FUNC" pressed (to power the interface from the DMM).
  - PCE PCE-DM32: Briefly press the "RS232" button.
  - RadioShack 22-812: Press and hold "SELECT" and "RANGE" together.
  - TekPower TP4000ZC: Briefly press the "RS232" button.
+ - Tenma 72-7750: Briefly press the "RS232C" button.
+ - UNI-T UT60G: Briefly press the "RS232C" button.
  - UNI-T UT61B/C/D: Press the "REL/RS232/USB" button for roughly 1 second.
  - UNI-T UT325: Briefly press the "SEND" button (as per manual). However, it
    appears that in practice you don't have to press the button (at least on