]> sigrok.org Git - libsigrok.git/blame_incremental - README.devices
hwdriver: introduce SR_CONF_FORCE_DETECT config key (scan option)
[libsigrok.git] / README.devices
... / ...
CommitLineData
1-------------------------------------------------------------------------------
2README.devices
3-------------------------------------------------------------------------------
4
5This README contains various notes for users of libsigrok (or frontends
6that are based on libsigrok) about device- and/or driver-specific issues.
7
8
9Firmware
10--------
11
12Some devices supported by libsigrok need a firmware to be uploaded every time
13the device is connected to the PC (usually via USB), before it can be used.
14
15The default locations where libsigrok expects the firmware files are:
16
17 $SIGROK_FIRMWARE_DIR (environment variable)
18 $HOME/.local/share/sigrok-firmware
19 $prefix/share/sigrok-firmware
20 /usr/local/share/sigrok-firmware
21 /usr/share/sigrok-firmware
22
23($prefix is usually /usr/local or /usr, depending on your ./configure options)
24
25For further information see the section below and also:
26
27 http://sigrok.org/wiki/Firmware
28
29
30Per-driver firmware requirements
31--------------------------------
32
33The following drivers/devices require a firmware upload upon connection:
34
35 - asix-sigma: The ASIX SIGMA and SIGMA2 require various firmware files,
36 depending on the settings used. These files are available from our
37 'sigrok-firmware' repository/project under a license which allows us
38 to redistribute them.
39
40 - dreamsourcelab-dslogic: The DreamSourceLab DSLogic/DSCope device series
41 requires various firmware files and FPGA bitstream files.
42 These can be extracted/downloaded from the vendor's GitHub repo using a
43 tool from our 'sigrok-util' repository/project.
44
45 - fx2lafw: Logic analyzers based on the Cypress FX2(LP) chip need the
46 firmware files from the 'sigrok-firmware-fx2lafw' repository/project.
47 The firmware is written from scratch and licensed under the GNU GPLv2+.
48
49 - hantek-6xxx: Certain oscilloscopes based on the Cypress FX2(LP) chip, such
50 as the Hantek 6022BE/6022BL, SainSmart DDS120, and Rocktech BM102, need the
51 firmware files from the 'sigrok-firmware-fx2lafw' repository/project.
52 The firmware is written from scratch and licensed under the GNU GPLv2+.
53
54 - hantek-dso: The Hantek DSO-2090 (and other supported models of the same
55 series of Hantek PC oscilloscopes) need firmware files.
56 These can be extracted from the vendor's Windows drivers using a tool
57 from our 'sigrok-util' repository/project.
58
59 - lecroy-logicstudio: The LeCroy LogicStudio requires FPGA bitstream files.
60 These can be extracted from the vendor's Windows software using a tool
61 from our 'sigrok-util' repository/project.
62 Additionally, it requires a Cypress FX2 firmware. This can be extracted
63 from the vendor's Windows software using another tool. Details:
64
65 http://sigrok.org/wiki/LeCroy_LogicStudio#Firmware
66
67 - saleae-logic16: The Saleae Logic16 needs a firmware file for the
68 Cypress FX2 chip in the device, as well as two FPGA bitstream files.
69 These can be extracted from the vendor's Linux application using a tool
70 from our 'sigrok-util' repository/project.
71
72 - saleae-logic-pro: The Saleae Logic Pro 16 needs a firmware file for the
73 Cypress FX3 chip in the device, as well as an FPGA bitstream file.
74 These can be extracted from the vendor's Linux application using a tool
75 from our 'sigrok-util' repository/project.
76
77 - sysclk-lwla:
78
79 - The Sysclk LWLA1034 requires various bitstream files.
80 These files are available from our 'sigrok-firmware' repository/project
81 under a license which allows us to redistribute them.
82
83 - The Sysclk LWLA1016 requires various bitstream files.
84 These can be extracted from the vendor's Windows drivers using a tool
85 from our 'sigrok-util' repository/project.
86
87 - sysclk-sla5032: The Sysclk SLA5032 needs an FPGA bitstream file.
88 This file can be copied (and renamed) from the Windows vendor software
89 installation directory. Details:
90
91 https://sigrok.org/wiki/Sysclk_SLA5032#Firmware
92
93The following drivers/devices do not need any firmware upload:
94
95 - agilent-dmm
96 - appa-55ii
97 - arachnid-labs-re-load-pro
98 - atten-pps3xxx
99 - baylibre-acme
100 - beaglelogic
101 - brymen-dmm
102 - cem-dt-885x
103 - center-3xx (including all subdrivers)
104 - chronovu-la
105 - colead-slm
106 - conrad-digi-35-cpu
107 - demo
108 - fluke-45
109 - fluke-dmm
110 - ftdi-la
111 - gmc-mh-1x-2x (including all subdrivers)
112 - gwinstek-gds-800
113 - gwinstek-gpd
114 - hameg-hmo
115 - hantek-4032l
116 - hp-3457a
117 - hp-3478a
118 - hung-chang-dso-2100
119 - ikalogic-scanalogic2
120 - ikalogic-scanaplus
121 - ipdbg-la
122 - kecheng-kc-330b
123 - kern-scale
124 - korad-kaxxxxp
125 - lascar-el-usb
126 - lecroy-xstream
127 - link-mso19
128 - manson-hcs-3xxx
129 - maynuo-m97
130 - mic-985xx (including all subdrivers)
131 - microchip-pickit2
132 - mooshimeter-dmm
133 - motech-lps-30x
134 - norma-dmm
135 - openbench-logic-sniffer
136 - pce-322a
137 - pipistrello-ols
138 - rdtech-dps
139 - rigol-ds
140 - rohde-schwarz-sme-0x
141 - scpi-dmm
142 - scpi-pps
143 - serial-dmm (including all subdrivers)
144 - serial-lcr (including all subdrivers)
145 - siglent-sds
146 - teleinfo
147 - testo
148 - tondaj-sl-814
149 - uni-t-dmm (including all subdrivers)
150 - uni-t-ut32x
151 - yokogawa-dlm
152 - zeroplus-logic-cube
153 - zketech-ebd-usb
154
155
156Specifying serial ports
157-----------------------
158
159Many devices supported by libsigrok use serial port based cables (real RS232
160or USB-to-serial ones, CDC class) to connect to a PC. These serial cables are
161supported by the libserialport library. Some vendors prefer to use HID chips
162instead of CDC chips in their serial cables. These cables can get supported
163by means of the hidapi library. Note that each chip type requires specific
164support in the libsigrok library. Bluetooth connected devices may be supported
165as well when they communicate by means of RFCOMM channels, or one of the
166implemented BLE notification/indication approaches, and one of the Bluetooth
167supporting platforms is used.
168
169For all these devices, you need to specify the serial port they are connected
170to (e.g. using the 'conn' option in sigrok-cli). It is not possible to scan
171for such devices without specifying a serial port.
172
173Example:
174
175 $ sigrok-cli --driver <somedriver>:conn=/dev/ttyUSB0 ...
176 $ sigrok-cli --driver <somedriver>:conn=hid/cp2110 ...
177 $ sigrok-cli --driver <somedriver>:conn=bt/rfcomm/01-23-45-67-89-ab ...
178
179Formal syntax for serial communication:
180
181 - COM ports (RS232, USB CDC):
182 conn=<com-port>
183 - USB HID cables:
184 conn=hid[/<chip>]
185 conn=hid[/<chip>]/usb=<bus>.<dev>[.<if>]
186 conn=hid[/<chip>]/raw=<path>
187 conn=hid[/<chip>]/sn=<serno>
188 conn=hid[/<chip>]/iokit=<path>
189 chip can be: bu86x, ch9325, cp2110, victor
190 path may contain slashes
191 path and serno are "greedy" (span to the end of the spec)
192 - Bluetooth Classic and Bluetooth Low Energy (BLE):
193 conn=bt/<conn>/<addr>
194 conn can be: rfcomm, ble122, nrf51, cc254x
195 addr can be "dense" or separated, bt/cc254x/0123456789ab or
196 bt/rfcomm/11-22-33-44-55-66 or bt/ble122/88:6b:12:34:56:78
197 (note that colons may not be available when the conn= spec is taken
198 from a string that separates fields by colon, e.g. in the "--driver
199 <name>:conn=<spec>" example, that is why the dense form and the use
200 of dashes for separation are supported)
201
202Some of the drivers implement a default for the connection. Some of the
203drivers can auto-detect USB connected devices.
204
205Beyond strict serial communication over COM ports (discussed above), the
206conn= property can also address specific USB devices, as well as specify TCP
207or VXI communication parameters. See these examples:
208
209 $ sigrok-cli --driver <somedriver>:conn=<vid>.<pid> ...
210 $ sigrok-cli --driver <somedriver>:conn=tcp-raw/<ipaddr>/<port> ...
211 $ sigrok-cli --driver <somedriver>:conn=vxi/<ipaddr> ...
212 $ sigrok-cli --driver <somedriver>:conn=usbtmc/<bus>.<addr> ...
213
214
215Specifying serial port parameters
216---------------------------------
217
218Every serial device's driver has default serial port parameters like baud
219rate, number of data bits, stop bits and handshake status. If a device requires
220different parameters, pass them as option "serialcomm" with the driver name.
221See libsigrok docs for the function serial_set_paramstr() for complete specs.
222
223Example:
224
225 $ sigrok-cli --driver <somedriver>:conn=<someconn>:serialcomm=9600/7n1/dtr=1
226
227
228Permissions of serial port based devices
229----------------------------------------
230
231When using devices supported by libsigrok that use serial port based cables
232(real RS232 or USB-to-serial ones) to connect to a PC, you need to ensure
233that the user running the libsigrok frontend has (read/write) permissions to
234access the serial port device (e.g. /dev/ttyS0, /dev/ttyUSB0, and so on).
235
236You can use 'chmod' to apply permissions as you see fit, and/or 'chown' to
237change the owner of the serial port device to a certain user or group.
238
239For USB-to-serial based devices, we recommended using our udev rules file
240(see below for details).
241
242
243Permissions for USB devices (udev rules files)
244----------------------------------------------
245
246When using USB-based devices supported by libsigrok, the user running the
247libsigrok frontend (e.g. sigrok-cli) has to have (read/write) permissions
248for the respective USB device.
249
250On Linux, this is accomplished using udev rules. libsigrok ships a rules
251file containing all supported devices which can be detected reliably
252(generic USB-to-serial converters are omitted, as these are used for a wide
253range of devices, e.g. GPS receivers, which are not handled by libsigrok).
254
255The file is available in contrib/60-libsigrok.rules. This file just contains
256the list of devices and flags these devices with ID_SIGROK="1". Access is
257granted by the 61-libsigrok-plugdev.rules or 61-libsigrok-uaccess.rules files,
258allowing access to members of the plugdev group or to currently logged in
259users, respectively.
260
261When using a libsigrok package from your favorite Linux distribution, the
262files should already be installed in /usr/lib/udev/rules.d/, i.e.
26360-libsigrok.rules and one of the access granting rules files. Use of
26461-libsigrok-uaccess.rules is encouraged on systemd distributions.
265
266The access policy can be locally overridden by placing appropriate rules in
267/etc/udev/rules.d/, disabling or ammending the default policy. See the
268udev documentation, e.g. man 7 udev, for details.
269
270If you're building from source, you need to copy the file to the place
271where udev will read these rules. Local rules should go to /etc/udev/rules.d.
272Keep the file naming, otherwise interaction between the libsigrok rules and
273rules shipped by the system will be broken.
274
275Please consult the udev docs for details.
276
277
278Cypress FX2 based devices
279-------------------------
280
281Devices using the Cypress FX2(LP) chip without any specific USB VID/PID will
282be enumerated with VID/PID 04b4:8613 (the default for "unconfigured FX2").
283These are usually "FX2 eval boards" (that can also be used as LAs, though).
284
285On Linux, the 'usbtest' driver will usually grab such devices, and they will
286thus not be usable by libsigrok (and frontends).
287
288You can fix this by running 'rmmod usbtest' as root before using the device.
289
290
291UNI-T DMM (and rebranded models) cables
292---------------------------------------
293
294UNI-T multimeters (and rebranded devices, e.g. some Voltcraft models) can
295ship with different PC connectivity cables:
296
297 - UT-D02 (RS232 cable)
298 - UT-D04 (USB/HID cable with Hoitek HE2325U chip, USB VID/PID 04fa:2490)
299 - UT-D04 (USB/HID cable with WCH CH9325 chip, USB VID/PID 1a86:e008)
300 - UT-D07 (Bluetooth adapter, ISSC BL79 BLETR chip)
301 - UT-D09 (USB/HID cable with SiL CP2110 chip, USB VID/PID 10c4:ea80)
302
303The above cables are all physically compatible (same IR connector shape)
304with all/most currently known UNI-T multimeters. For example, you can
305use either of the UT-D04 USB/HID cables or the UT-D02 RS232 cable with
306the UNI-T UT61D multimeter.
307
308When using the UT-D02 RS232 cable with any of the supported UNI-T DMMs,
309you have to use the respective driver with a '-ser' drivername suffix
310(internally all of these models are handled by the 'serial-dmm' driver).
311
312You also need to specify the serial port via the 'conn' option, e.g.
313/dev/ttyUSB0 (attached via a USB-to-serial cable) or /dev/ttyS0 (actual
314RS232 port) on Linux (see above).
315
316Finally, the user running the frontend (e.g. sigrok-cli) also needs
317permissions to access the respective serial port (see above).
318
319Examples (sigrok-cli):
320
321 $ sigrok-cli --driver uni-t-ut61e-ser:conn=/dev/ttyUSB0 ...
322 $ sigrok-cli --driver voltcraft-vc820-ser:conn=/dev/ttyS0 ...
323
324When using any of the UT-D04 USB/HID cables you have to use the respective
325driver _without_ the '-ser' drivername suffix (internally all of these models
326are handled by the 'uni-t-dmm' driver).
327
328You also need to specify the USB vendor/device IDs of the cable.
329Autodetection is not possible here, since various other products use the
330USB VID/PID of those cables too, and there is no way to distinguish them.
331
332Since the UT-D04 cables are USB based (but don't use a USB-to-serial chip)
333there is no need to specify a serial port via 'conn', of course.
334However, the user running the frontend does also need to have permissions
335to access the respective USB device (see above).
336
337Examples (sigrok-cli):
338
339 $ sigrok-cli --driver uni-t-ut61e:conn=1a86.e008 ...
340 $ sigrok-cli --driver voltcraft-vc820:conn=04fa.2490 ...
341
342
343UNI-T UT-D04 cable issue on Linux
344---------------------------------
345
346The UNI-T UT-D04 cable with Hoitek HE2325U (or WCH CH9325) chip seems to have
347a very specific problem on Linux. Apparently it requires to be put into
348suspend (and woken up again) before it is usable. This seems to be a
349Linux-only issue, Windows is not affected by this since apparently the
350Windows kernel does this for every USB device, always.
351
352Thus, if you want to use any of the UNI-T DMMs with this specific cable,
353you'll have to run the following script (as root) once, every time you attach
354the cable via USB. The script was written by Ralf Burger.
355
356See also: http://erste.de/UT61/index.html
357
358 #!/bin/bash
359 for dat in /sys/bus/usb/devices/*; do
360 if test -e $dat/manufacturer; then
361 grep "WCH.CN" $dat/manufacturer > /dev/null && echo auto > ${dat}/power/level && echo 0 > ${dat}/power/autosuspend
362 fi
363 done
364
365
366Enabling multimeter / data logger measurement output
367----------------------------------------------------
368
369Some multimeters or data loggers will not start outputting measurement data
370unless a certain action has been performed by the user beforehand. This is
371usually mentioned in the vendor manual of the respective device, but here's
372a short list for convenience:
373
374 - BBC Goertz Metrawatt M2110: Briefly press the "Start/Reset" button on the
375 interface panel on top.
376 - Brymen BM257s: Press HOLD during power-on.
377 - Digitek DT4000ZC: Briefly press the "RS232" button.
378 - EEVBlog 121GW: Hold "1ms PEAK" until the "BT" indicator is shown.
379 - ES51919 based LCR meters (DER EE DE-5000, PeakTech 2170, UNI-T UT612):
380 Press the button with the "RS232" or "USB" or "PC link" label (usually
381 the "up" cursor button).
382 - Gossen Metrawatt Metrahit 1x/2x devices, driver gmc-mh-1x-2x-rs232:
383 - Power on the device with the "DATA" button pressed.
384 - Metrahit 2x devices must be configured for the respective interface type.
385 - Gossen Metrawatt Metrahit 2x devices, driver gmc-mh-2x-bd232:
386 - 'BD232' interface:
387 The multimeter must be configured for the respective interface type.
388 - 'SI232-II' interface ("PC Mode"):
389 The multimeter must be configured for interface type 'BD232' (all),
390 'SI232 online' (28-29S) or 'SI232 store' (22-26x). The interface must
391 be configured to the same baud rate as the host (default 9600).
392 Multimeter and interface must be configured to the same address.
393 - MASTECH MS6514: Press the "Setup/PC-Link" button for roughly 3 seconds.
394 - Metrix MX56C: Press the PRINT button to have the meter send acquisition
395 data via IR. Hold the PRINT button to adjust the meter's transmission
396 interval.
397 - Norma DM950: If the interface doesn't work (e.g. USB-RS232 converter), power
398 on the device with "FUNC" pressed (to power the interface from the DMM).
399 - PCE PCE-DM32: Briefly press the "RS232" button.
400 - RadioShack 22-812: Press and hold "SELECT" and "RANGE" together.
401 - TekPower TP4000ZC: Briefly press the "RS232" button.
402 - Tenma 72-7750: Briefly press the "RS232C" button.
403 - UNI-T UT60G: Briefly press the "RS232C" button.
404 - UNI-T UT61B/C/D: Press the "REL/RS232/USB" button for roughly 1 second.
405 - UNI-T UT71x: Press the "SEND/-/MAXMIN" button for roughly 1 second.
406 Briefly pressing the "EXIT" button leaves this mode again.
407 - UNI-T UT181A: In the "SETUP" menu set "Communication" to "ON".
408 - UNI-T UT325: Briefly press the "SEND" button (as per manual). However, it
409 appears that in practice you don't have to press the button (at least on
410 some versions of the device), simply connect the device via USB.
411 - V&A VA18B/VA40B: Keep the "Hz/DUTY" key pressed while powering on the DMM.
412 - Victor 70C/86C: Press the "REL/RS232" button for roughly 1 second.
413 - Voltcraft VC-830: Press the "REL/PC" button for roughly 2 seconds.
414 - Voltcraft VC-870: Press the "REL/PC" button for roughly 1 second.
415
416
417ChronoVu LA8/LA16 USB VID/PIDs
418------------------------------
419
420The ChronoVu LA8/LA16 logic analyzer is available in two revisions. Previously,
421the device shipped with a USB VID/PID of 0403:6001, which is the standard ID
422for FTDI FT232 USB chips.
423
424Since this made it hard to distinguish the LA8/LA16 from any other device
425with this FTDI chip connected to the PC, the vendor later shipped the
426device with a USB VID/PID of 0403:8867.
427
428The 'chronovu-la' driver in libsigrok supports both VID/PID pairs and
429automatically finds devices with either VID/PID pair.
430
431
432OLS
433---
434
435The Dangerous Prototypes Openbench Logic Sniffer (OLS) logic analyzer
436driver in libsigrok assumes a somewhat recent firmware has been flashed onto
437the OLS (it doesn't need a firmware upload every time it's attached via USB,
438since the firmware is stored in the device permanently).
439
440The most recent firmware version that is tested is 3.07.
441
442If you use any older firmware and your OLS is not found or is not working
443properly, please upgrade to at least this firmware version. Check the
444Dangerous Prototypes wiki for firmware upgrade instructions:
445
446 http://dangerousprototypes.com/docs/Logic_Sniffer_upgrade_procedure
447
448Also, you need to specify a serial port for the OLS in the frontends, e.g.
449using the 'conn' option in sigrok-cli, and you also need to have the
450permissions to access the serial port (see above).
451
452Example:
453
454 $ sigrok-cli --driver ols:conn=/dev/ttyACM0 ...
455
456
457Mooshimeter
458-----------
459
460The Mooshim Engineering Mooshimeter is controlled via Bluetooth Low Energy
461(sometimes called Bluetooth 4.0), as such it requires a supported Bluetooth
462interface available. The 'conn' option is required and must contain the
463Bluetooth MAC address of the meter.
464
465Example:
466
467 $ sigrok-cli --driver mooshimeter-dmm:conn=12-34-56-78-9A-BC ...
468
469Since the Mooshimeter has no physical interface on the meter itself, the
470channel configuration is set with the 'channel_config' option. The format
471of this option is 'CH1,CH2' where each channel configuration has the form
472'MODE:RANGE:ANALYSIS', with later parts being optional. In addition for
473CLI compatibility, the ',' in the channels can also be a '/' and the ':' in
474the individual configuration can be a ';'.
475
476Available channel 1 modes:
477
478 - Current, A: Current in amps
479 - Temperature, T, K: Internal meter temperature in Kelvin
480 - Resistance, Ohm, W: Resistance in ohms
481 - Diode, D: Diode voltage
482 - Aux, LV: Auxiliary (W input) low voltage sensor (1.2V max)
483
484Available channel 2 modes:
485
486 - Voltage, V: Voltage
487 - Temperature, T, K: Internal meter temperature in Kelvin
488 - Resistance, Ohm, W: Resistance in ohms
489 - Diode, D: Diode voltage
490 - Aux, LV: Auxiliary (W input) low voltage sensor (1.2V max)
491
492Only one channel can use the shared inputs at a time (e.g. if CH1 is measuring
493resistance, CH2 cannot measure low voltage). Temperature is excepted from
494this, so the meter can measure internal temperature and low voltage at the
495same time.
496
497Additionally, the meter can calculate the real power of both channels. This
498generally only makes sense when CH1 is set to current and CH2 is set to a
499voltage and so it is disabled by default. It must be enabled by enabling the
500'P' channel (the third channel).
501
502The range of the channel specification sets the maximum input for that channel
503and is rounded up to the next value the meter itself supports. For example,
504specifying 50 for the voltage will result in the actual maximum of 60.
505Specifying 61 would result in 600. If omitted, sigrok will perform
506auto-ranging of the channel by selecting the next greater value than the
507latest maximum.
508
509The analysis option sets how the meter reports its internal sampling buffer
510to sigrok:
511
512 - Mean, DC: The default is a simple arithmetic mean of the sample buffer
513 - RMS, AC: The root mean square of the sample buffer
514 - Buf, Buffer, Samples: Report the entire sample buffer to sigrok. This
515 results in packets that contain all the samples in the buffer instead
516 of a single output value.
517
518The size of the sample buffer is set with the 'avg_samples' option, while
519the sampling rate is set with the 'samplerate' option. So the update rate
520is avg_samples/samplerate. Both are rounded up to the next supported value
521by the meter.
522