* EEVblog 121GW 19-bytes binary protocol parser.
*
- * @internal
- *
* Note that this protocol is different from other meters. We need not
* decode the LCD presentation (segments a-g and dot of seven segment
* displays). Neither need we decode a textual presentation consisting
* @return SR_OK upon success, SR_ERR upon failure. Upon errors, the
* 'analog' variable contents are undefined and should not be used.
*/
-SR_PRIV int sr_eev121gw_parse(const uint8_t *buf, float *floatval,
+static int sr_eev121gw_parse(const uint8_t *buf, float *floatval,
struct sr_datafeed_analog *analog, void *info)
{
struct eev121gw_info *info_local;
/*
* Get those fields which correspond to the secondary
* display. The value's mantissa has 16 bits. The sign
- * is separate is only applies to some of the modes.
+ * is separate and only applies to some of the modes.
* Scaling and precision also depend on the mode. The
* interpretation of the secondary display is different
* from the main display: The 'range' is not an index
}
is_k = FIELD_NB(raw_sub_range, SUB_RANGE_K);
- /*
- * TODO: Re-check the power mode display as more data becomes
- * available.
- *
- * The interpretation of the secondary display in power (VA)
- * modes is uncertain. The mode suggests A or uA units but the
- * value is supposed to be mA without a reliable condition
- * for us to check...
- *
- * f2 17 84 21 21 18 02 00 00 01 04 00 0b 00 00 0a 40 00 3f
- * f2 17 84 21 21 18 02 00 00 15 03 00 00 00 00 0a 40 00 27
- * DC VA DC V / DC A
- * 25.000VA dot 4 / dot 3
- *
- * f2 17 84 21 21 18 00 00 26 01 04 4c 57 00 00 0e 40 00 0f
- * f2 17 84 21 21 18 00 00 26 15 02 00 c7 00 00 0e 40 00 c1
- * 3.8mVA DC 1.9543V
- * 1.98mA (!) DC A + dot 2 -> milli(!) amps?
- *
- * f2 17 84 21 21 17 00 07 85 01 04 4c 5a 00 00 0e 40 00 a9
- * f2 17 84 21 21 17 00 07 85 13 04 26 7b 00 00 0e 40 00 f0
- * 1.925mVA DC 1.9546V
- * 0.9852mA
- *
- * f2 17 84 21 21 16 02 11 e0 01 04 26 39 00 02 0e 40 00 d2
- * f2 17 84 21 21 16 02 11 e0 11 04 12 44 00 02 0e 40 00 8b
- * 457.6uVA DC 0.9785V
- * 0.4676mA (!) DC uA + dot 4 -> milli(!) amps?
- */
-
switch (sub_mode) {
case MODE_DC_V:
info_local->is_voltage = TRUE;