Logic analyzer setup
--------------------
-The logic analyzer used for capturing was a ChronoVu LA8 at a sample rate
-of 1MHz. The logic analyzer probes were connected to the RTC chip like this:
+The logic analyzer used was a ChronoVu LA8 (at 1MHz):
Probe RTC chip pin
------------------------
0 (green) SCL
1 (orange) SDA
- GND GND
Data
S Wr:0xa2 A 0x02 A Sr Rd:0xa3 A 0x54 A 0x03 A 0x44 A 0x62 A 0x52 A
0x51 A 0x11 N P
- - The abbrevations used above: S = Start, Wr = Write, A = ACK, P = Stop,
+ - The abbreviations used above: S = Start, Wr = Write, A = ACK, P = Stop,
Sr = Repeated start, Rd = Read, N = NACK
The sigrok command line used was: