]> sigrok.org Git - libsigrok.git/blobdiff - README.devices
Re-enable link-mso19 and nexus-osciprime drivers.
[libsigrok.git] / README.devices
index 95d92cc43aefb5a732b0d6c6e4a6bfd68df0a3b6..fefbfc470ae7c8e67a663cd53324ffa11f2a846f 100644 (file)
@@ -42,6 +42,9 @@ The following drivers/devices require a firmware upload upon connection:
    These can be extracted from the vendor's Windows drivers using a tool
    from our 'sigrok-util' repository/project.
 
+ - nexus-osciprime: The Nexus Computing OsciPrime PC oscilloscope needs
+   firmware files. These are available from the vendor website.
+
 The following drivers/devices do not need any firmware upload:
 
  - agilent-dmm
@@ -52,6 +55,7 @@ The following drivers/devices do not need any firmware upload:
  - demo
  - fluke-dmm
  - lascar-el-usb
+ - link-mso19
  - mic-985xx
  - openbench-logic-sniffer
  - rigol-ds1xx2
@@ -82,7 +86,9 @@ The following drivers/devices require a serial port specification:
  - brymen-dmm
  - colead-slm
  - fluke-dmm
+ - link-mso19
  - mic-985xx
+ - nexus-osciprime
  - openbench-logic-sniffer
  - serial-dmm
  - tondaj-sl-814
@@ -228,6 +234,24 @@ See also: http://erste.de/UT61/index.html
   done
 
 
+Enabling multimeter / data logger measurement output
+----------------------------------------------------
+
+Some multimeters or data loggers will not start outputting measurement data
+unless a certain action has been performed by the user beforehand. This is
+usually mentioned in the vendor manual of the respective device, but here's
+a short list for convenience:
+
+ - Digitek DT4000ZC: Briefly press the "RS232" button.
+ - PCE PCE-DM32: Briefly press the "RS232" button.
+ - RadioShack 22-812: Press and hold "SELECT" and "RANGE" together.
+ - TekPower TP4000ZC: Briefly press the "RS232" button.
+ - UNI-T UT61D: Press the "REL/RS232/USB" button for roughly 1 second.
+ - V&A VA18B: Keep the "Hz/DUTY" key pressed while powering on the device.
+ - Victor 70C: Press the "REL/RS232" button for roughly 1 second.
+ - Victor 86C: Press the "REL/RS232" button for roughly 1 second.
+
+
 ALSA driver
 -----------
 
@@ -242,6 +266,16 @@ We might write additional drivers to make a similar functionality available
 on other OSes at some point.
 
 
+Link Instruments MSO-19
+-----------------------
+
+The driver for the Link Instruments MSO-19 mixed-signal oscilloscope (MSO)
+is currently using libudev (which is a library for the Linux-specific udev
+system). Thus, this driver can currently only compile and work on Linux.
+
+We plan to fix this though, so that it'll work on all other OSes, too.
+
+
 ChronoVu LA8 USB VID/PIDs
 -------------------------