]> sigrok.org Git - libsigrok.git/blobdiff - README.devices
Initial Comma-separated values (CSV) input support.
[libsigrok.git] / README.devices
index 95d92cc43aefb5a732b0d6c6e4a6bfd68df0a3b6..3e981ec73e3e1d86c7d2f460c81d1f1dc0898bc2 100644 (file)
@@ -42,22 +42,34 @@ The following drivers/devices require a firmware upload upon connection:
    These can be extracted from the vendor's Windows drivers using a tool
    from our 'sigrok-util' repository/project.
 
+ - saleae-logic16: The Saleae Logic16 needs a firmware file for the
+   Cypress FX2 chip in the device, as well as two FPGA bitstream files.
+   These can be extracted from the vendor's Linux application using a tool
+   from our 'sigrok-util' repository/project.
+
 The following drivers/devices do not need any firmware upload:
 
  - agilent-dmm
  - alsa
  - brymen-dmm
+ - cem-dt-885x
+ - center-3xx
  - chronovu-la8
  - colead-slm
  - demo
  - fluke-dmm
+ - ikalogic-scanalogic2
+ - ikalogic-scanaplus
+ - kecheng-kc-330b
  - lascar-el-usb
+ - link-mso19
  - mic-985xx
  - openbench-logic-sniffer
  - rigol-ds1xx2
  - serial-dmm
  - tondaj-sl-814
  - uni-t-dmm
+ - uni-t-ut32x
  - victor-dmm
  - zeroplus-logic-cube
 
@@ -80,8 +92,11 @@ The following drivers/devices require a serial port specification:
 
  - agilent-dmm
  - brymen-dmm
+ - cem-dt-885x
+ - center-3xx
  - colead-slm
  - fluke-dmm
+ - link-mso19
  - mic-985xx
  - openbench-logic-sniffer
  - serial-dmm
@@ -95,9 +110,14 @@ The following drivers/devices do not require a serial port specification:
  - demo
  - fx2lafw
  - hantek-dso
+ - ikalogic-scanalogic2
+ - ikalogic-scanaplus
+ - kecheng-kc-330b
  - lascar-el-usb
  - rigol-ds1xx2
+ - saleae-logic16
  - uni-t-dmm
+ - uni-t-ut32x
  - victor-dmm
  - zeroplus-logic-cube
 
@@ -228,6 +248,28 @@ See also: http://erste.de/UT61/index.html
   done
 
 
+Enabling multimeter / data logger measurement output
+----------------------------------------------------
+
+Some multimeters or data loggers will not start outputting measurement data
+unless a certain action has been performed by the user beforehand. This is
+usually mentioned in the vendor manual of the respective device, but here's
+a short list for convenience:
+
+ - Digitek DT4000ZC: Briefly press the "RS232" button.
+ - PCE PCE-DM32: Briefly press the "RS232" button.
+ - RadioShack 22-812: Press and hold "SELECT" and "RANGE" together.
+ - TekPower TP4000ZC: Briefly press the "RS232" button.
+ - UNI-T UT61D: Press the "REL/RS232/USB" button for roughly 1 second.
+ - UNI-T UT325: Briefly press the "SEND" button (as per manual). However, it
+   appears that in practice you don't have to press the button (at least on
+   some versions of the device), simply connect the device via USB.
+ - V&A VA18B: Keep the "Hz/DUTY" key pressed while powering on the device.
+ - Victor 70C: Press the "REL/RS232" button for roughly 1 second.
+ - Victor 86C: Press the "REL/RS232" button for roughly 1 second.
+ - Voltcraft VC-830: Press the "REL/PC" button for roughly 2 seconds.
+
+
 ALSA driver
 -----------
 
@@ -242,6 +284,16 @@ We might write additional drivers to make a similar functionality available
 on other OSes at some point.
 
 
+Link Instruments MSO-19
+-----------------------
+
+The driver for the Link Instruments MSO-19 mixed-signal oscilloscope (MSO)
+is currently using libudev (which is a library for the Linux-specific udev
+system). Thus, this driver can currently only compile and work on Linux.
+
+We plan to fix this though, so that it'll work on all other OSes, too.
+
+
 ChronoVu LA8 USB VID/PIDs
 -------------------------