+/* Rigol DP700 series */
+static const uint32_t rigol_dp700_devopts[] = {
+ SR_CONF_CONTINUOUS,
+ SR_CONF_LIMIT_SAMPLES | SR_CONF_GET | SR_CONF_SET,
+ SR_CONF_LIMIT_MSEC | SR_CONF_GET | SR_CONF_SET,
+};
+
+static const uint32_t rigol_dp700_devopts_cg[] = {
+ SR_CONF_REGULATION | SR_CONF_GET,
+ SR_CONF_OVER_VOLTAGE_PROTECTION_ENABLED | SR_CONF_GET | SR_CONF_SET,
+ SR_CONF_OVER_VOLTAGE_PROTECTION_ACTIVE | SR_CONF_GET,
+ SR_CONF_OVER_VOLTAGE_PROTECTION_THRESHOLD | SR_CONF_GET | SR_CONF_SET | SR_CONF_LIST,
+ SR_CONF_OVER_CURRENT_PROTECTION_ENABLED | SR_CONF_GET | SR_CONF_SET,
+ SR_CONF_OVER_CURRENT_PROTECTION_ACTIVE | SR_CONF_GET,
+ SR_CONF_OVER_CURRENT_PROTECTION_THRESHOLD | SR_CONF_GET | SR_CONF_SET | SR_CONF_LIST,
+ SR_CONF_VOLTAGE | SR_CONF_GET,
+ SR_CONF_VOLTAGE_TARGET | SR_CONF_GET | SR_CONF_SET | SR_CONF_LIST,
+ SR_CONF_CURRENT | SR_CONF_GET,
+ SR_CONF_CURRENT_LIMIT | SR_CONF_GET | SR_CONF_SET | SR_CONF_LIST,
+ SR_CONF_ENABLED | SR_CONF_GET | SR_CONF_SET,
+};
+
+static const struct channel_spec rigol_dp711_ch[] = {
+ { "1", { 0, 30, 0.01, 3, 3 }, { 0, 5, 0.01, 3, 3 }, { 0, 150, 0, 3, 3 }, FREQ_DC_ONLY, { 0.01, 33, 0.01}, { 0.01, 5.5, 0.01 } },
+};
+
+static const struct channel_spec rigol_dp712_ch[] = {
+ { "1", { 0, 50, 0.01, 3, 3 }, { 0, 3, 0.01, 3, 3 }, { 0, 150, 0, 3, 3 }, FREQ_DC_ONLY, { 0.01, 55, 0.01}, { 0.01, 3.3, 0.01 } },
+};
+
+static const struct channel_group_spec rigol_dp700_cg[] = {
+ { "1", CH_IDX(0), PPS_OVP | PPS_OCP, SR_MQFLAG_DC },
+};
+
+/* Same as the DP800 series, except for the missing :SYST:OTP* commands. */
+static const struct scpi_command rigol_dp700_cmd[] = {
+ { SCPI_CMD_REMOTE, "SYST:REMOTE" },
+ { SCPI_CMD_LOCAL, "SYST:LOCAL" },
+ { SCPI_CMD_BEEPER, "SYST:BEEP:STAT?" },
+ { SCPI_CMD_BEEPER_ENABLE, "SYST:BEEP:STAT ON" },
+ { SCPI_CMD_BEEPER_DISABLE, "SYST:BEEP:STAT OFF" },
+ { SCPI_CMD_SELECT_CHANNEL, ":INST:NSEL %s" },
+ { SCPI_CMD_GET_MEAS_VOLTAGE, ":MEAS:VOLT?" },
+ { SCPI_CMD_GET_MEAS_CURRENT, ":MEAS:CURR?" },
+ { SCPI_CMD_GET_MEAS_POWER, ":MEAS:POWE?" },
+ { SCPI_CMD_GET_VOLTAGE_TARGET, ":SOUR:VOLT?" },
+ { SCPI_CMD_SET_VOLTAGE_TARGET, ":SOUR:VOLT %.6f" },
+ { SCPI_CMD_GET_CURRENT_LIMIT, ":SOUR:CURR?" },
+ { SCPI_CMD_SET_CURRENT_LIMIT, ":SOUR:CURR %.6f" },
+ { SCPI_CMD_GET_OUTPUT_ENABLED, ":OUTP?" },
+ { SCPI_CMD_SET_OUTPUT_ENABLE, ":OUTP ON" },
+ { SCPI_CMD_SET_OUTPUT_DISABLE, ":OUTP OFF" },
+ { SCPI_CMD_GET_OUTPUT_REGULATION, ":OUTP:MODE?" },
+ { SCPI_CMD_GET_OVER_VOLTAGE_PROTECTION_ENABLED, ":OUTP:OVP?" },
+ { SCPI_CMD_SET_OVER_VOLTAGE_PROTECTION_ENABLE, ":OUTP:OVP ON" },
+ { SCPI_CMD_SET_OVER_VOLTAGE_PROTECTION_DISABLE, ":OUTP:OVP OFF" },
+ { SCPI_CMD_GET_OVER_VOLTAGE_PROTECTION_ACTIVE, ":OUTP:OVP:QUES?" },
+ { SCPI_CMD_GET_OVER_VOLTAGE_PROTECTION_THRESHOLD, ":OUTP:OVP:VAL?" },
+ { SCPI_CMD_SET_OVER_VOLTAGE_PROTECTION_THRESHOLD, ":OUTP:OVP:VAL %.6f" },
+ { SCPI_CMD_GET_OVER_CURRENT_PROTECTION_ENABLED, ":OUTP:OCP?" },
+ { SCPI_CMD_SET_OVER_CURRENT_PROTECTION_ENABLE, ":OUTP:OCP:STAT ON" },
+ { SCPI_CMD_SET_OVER_CURRENT_PROTECTION_DISABLE, ":OUTP:OCP:STAT OFF" },
+ { SCPI_CMD_GET_OVER_CURRENT_PROTECTION_ACTIVE, ":OUTP:OCP:QUES?" },
+ { SCPI_CMD_GET_OVER_CURRENT_PROTECTION_THRESHOLD, ":OUTP:OCP:VAL?" },
+ { SCPI_CMD_SET_OVER_CURRENT_PROTECTION_THRESHOLD, ":OUTP:OCP:VAL %.6f" },
+ ALL_ZERO
+};
+