]> sigrok.org Git - libsigrok.git/blobdiff - README.devices
README.devices: Updates.
[libsigrok.git] / README.devices
old mode 100755 (executable)
new mode 100644 (file)
index ae3ac50..ecd2ffc
@@ -42,26 +42,36 @@ The following drivers/devices require a firmware upload upon connection:
    These can be extracted from the vendor's Windows drivers using a tool
    from our 'sigrok-util' repository/project.
 
    These can be extracted from the vendor's Windows drivers using a tool
    from our 'sigrok-util' repository/project.
 
- - nexus-osciprime: The Nexus Computing OsciPrime PC oscilloscope needs
-   firmware files. These are available from the vendor website.
+ - saleae-logic16: The Saleae Logic16 needs a firmware file for the
+   Cypress FX2 chip in the device, as well as two FPGA bitstream files.
+   These can be extracted from the vendor's Linux application using a tool
+   from our 'sigrok-util' repository/project.
 
 The following drivers/devices do not need any firmware upload:
 
  - agilent-dmm
  - alsa
  - brymen-dmm
 
 The following drivers/devices do not need any firmware upload:
 
  - agilent-dmm
  - alsa
  - brymen-dmm
+ - cem-dt-885x
+ - center-3xx
  - chronovu-la8
  - colead-slm
  - demo
  - fluke-dmm
  - chronovu-la8
  - colead-slm
  - demo
  - fluke-dmm
+ - ikalogic-scanalogic2
+ - ikalogic-scanaplus
+ - kecheng-kc-330b
  - lascar-el-usb
  - link-mso19
  - mic-985xx
  - lascar-el-usb
  - link-mso19
  - mic-985xx
+ - norma-dmm
  - openbench-logic-sniffer
  - rigol-ds1xx2
  - serial-dmm
  - openbench-logic-sniffer
  - rigol-ds1xx2
  - serial-dmm
+ - teleinfo
  - tondaj-sl-814
  - uni-t-dmm
  - tondaj-sl-814
  - uni-t-dmm
+ - uni-t-ut32x
  - victor-dmm
  - zeroplus-logic-cube
 
  - victor-dmm
  - zeroplus-logic-cube
 
@@ -84,13 +94,16 @@ The following drivers/devices require a serial port specification:
 
  - agilent-dmm
  - brymen-dmm
 
  - agilent-dmm
  - brymen-dmm
+ - cem-dt-885x
+ - center-3xx
  - colead-slm
  - fluke-dmm
  - link-mso19
  - mic-985xx
  - colead-slm
  - fluke-dmm
  - link-mso19
  - mic-985xx
- - nexus-osciprime
+ - norma-dmm
  - openbench-logic-sniffer
  - serial-dmm
  - openbench-logic-sniffer
  - serial-dmm
+ - teleinfo
  - tondaj-sl-814
 
 The following drivers/devices do not require a serial port specification:
  - tondaj-sl-814
 
 The following drivers/devices do not require a serial port specification:
@@ -101,9 +114,14 @@ The following drivers/devices do not require a serial port specification:
  - demo
  - fx2lafw
  - hantek-dso
  - demo
  - fx2lafw
  - hantek-dso
+ - ikalogic-scanalogic2
+ - ikalogic-scanaplus
+ - kecheng-kc-330b
  - lascar-el-usb
  - rigol-ds1xx2
  - lascar-el-usb
  - rigol-ds1xx2
+ - saleae-logic16
  - uni-t-dmm
  - uni-t-dmm
+ - uni-t-ut32x
  - victor-dmm
  - zeroplus-logic-cube
 
  - victor-dmm
  - zeroplus-logic-cube
 
@@ -215,7 +233,7 @@ UNI-T UT-D04 cable issue on Linux
 ---------------------------------
 
 The UNI-T UT-D04 cable with Hoitek HE2325U (or WCH CH9325) chip seems to have
 ---------------------------------
 
 The UNI-T UT-D04 cable with Hoitek HE2325U (or WCH CH9325) chip seems to have
-a very specific problem on Linux. Apparently it requires to be put into
+a very specific problem on Linux. Apparently it requires to be put into
 suspend (and woken up again) before it is usable. This seems to be a
 Linux-only issue, Windows is not affected by this since apparently the
 Windows kernel does this for every USB device, always.
 suspend (and woken up again) before it is usable. This seems to be a
 Linux-only issue, Windows is not affected by this since apparently the
 Windows kernel does this for every USB device, always.
@@ -234,6 +252,28 @@ See also: http://erste.de/UT61/index.html
   done
 
 
   done
 
 
+Enabling multimeter / data logger measurement output
+----------------------------------------------------
+
+Some multimeters or data loggers will not start outputting measurement data
+unless a certain action has been performed by the user beforehand. This is
+usually mentioned in the vendor manual of the respective device, but here's
+a short list for convenience:
+
+ - Digitek DT4000ZC: Briefly press the "RS232" button.
+ - PCE PCE-DM32: Briefly press the "RS232" button.
+ - RadioShack 22-812: Press and hold "SELECT" and "RANGE" together.
+ - TekPower TP4000ZC: Briefly press the "RS232" button.
+ - UNI-T UT61D: Press the "REL/RS232/USB" button for roughly 1 second.
+ - UNI-T UT325: Briefly press the "SEND" button (as per manual). However, it
+   appears that in practice you don't have to press the button (at least on
+   some versions of the device), simply connect the device via USB.
+ - V&A VA18B: Keep the "Hz/DUTY" key pressed while powering on the device.
+ - Victor 70C: Press the "REL/RS232" button for roughly 1 second.
+ - Victor 86C: Press the "REL/RS232" button for roughly 1 second.
+ - Voltcraft VC-830: Press the "REL/PC" button for roughly 2 seconds.
+
+
 ALSA driver
 -----------
 