SR_PRIV struct sr_dev_driver ikalogic_scanaplus_driver_info;
-static int dev_acquisition_stop(struct sr_dev_inst *sdi, void *cb_data);
+static int dev_acquisition_stop(struct sr_dev_inst *sdi);
static void clear_helper(void *priv)
{
return std_dev_clear(di, clear_helper);
}
-static int init(struct sr_dev_driver *di, struct sr_context *sr_ctx)
-{
- return std_init(sr_ctx, di, LOG_PREFIX);
-}
-
static GSList *scan(struct sr_dev_driver *di, GSList *options)
{
struct sr_dev_inst *sdi;
/* Register the device with libsigrok. */
sdi = g_malloc0(sizeof(struct sr_dev_inst));
- sdi->status = SR_ST_INITIALIZING;
+ sdi->status = SR_ST_INACTIVE;
sdi->vendor = g_strdup(USB_VENDOR_NAME);
sdi->model = g_strdup(USB_MODEL_NAME);
sdi->driver = di;
return NULL;
}
-static GSList *dev_list(const struct sr_dev_driver *di)
-{
- return ((struct drv_context *)(di->context))->instances;
-}
-
static int dev_open(struct sr_dev_inst *sdi)
{
struct dev_context *devc;
return ret;
}
-static int cleanup(const struct sr_dev_driver *di)
-{
- return dev_clear(di);
-}
-
static int config_get(uint32_t key, GVariant **data, const struct sr_dev_inst *sdi,
const struct sr_channel_group *cg)
{
return SR_OK;
}
-static int dev_acquisition_start(const struct sr_dev_inst *sdi, void *cb_data)
+static int dev_acquisition_start(const struct sr_dev_inst *sdi)
{
int ret;
struct dev_context *devc;
if (sdi->status != SR_ST_ACTIVE)
return SR_ERR_DEV_CLOSED;
- if (!(devc = sdi->priv))
- return SR_ERR_BUG;
+ devc = sdi->priv;
if (!devc->ftdic)
return SR_ERR_BUG;
/* TODO: Configure channels later (thresholds etc.). */
- devc->cb_data = cb_data;
-
/* Properly reset internal variables before every new acquisition. */
devc->compressed_bytes_ignored = 0;
devc->samples_sent = 0;
return SR_OK;
}
-static int dev_acquisition_stop(struct sr_dev_inst *sdi, void *cb_data)
+static int dev_acquisition_stop(struct sr_dev_inst *sdi)
{
- (void)cb_data;
-
sr_dbg("Stopping acquisition.");
sr_session_source_remove(sdi->session, -1);
std_session_send_df_end(sdi, LOG_PREFIX);
.name = "ikalogic-scanaplus",
.longname = "IKALOGIC ScanaPLUS",
.api_version = 1,
- .init = init,
- .cleanup = cleanup,
+ .init = std_init,
+ .cleanup = std_cleanup,
.scan = scan,
- .dev_list = dev_list,
+ .dev_list = std_dev_list,
.dev_clear = dev_clear,
.config_get = config_get,
.config_set = config_set,