## Foundation, Inc., 51 Franklin St, Fifth Floor, Boston, MA 02110-1301 USA
##
-# 1-Wire protocol decoder (link layer)
-
import sigrokdecode as srd
+class SamplerateError(Exception):
+ pass
+
class Decoder(srd.Decoder):
- api_version = 1
+ api_version = 2
id = 'onewire_link'
name = '1-Wire link layer'
longname = '1-Wire serial communication bus (link layer)'
license = 'gplv2+'
inputs = ['logic']
outputs = ['onewire_link']
- probes = [
+ channels = (
{'id': 'owr', 'name': 'OWR', 'desc': '1-Wire signal line'},
- ]
- optional_probes = [
+ )
+ optional_channels = (
{'id': 'pwr', 'name': 'PWR', 'desc': '1-Wire power supply pin'},
- ]
- options = {
- 'overdrive': ['Overdrive', 1],
+ )
+ options = (
+ {'id': 'overdrive',
+ 'desc': 'Overdrive mode', 'default': 'no', 'values': ('yes', 'no')},
# Time options (specified in microseconds):
- 'cnt_normal_bit': ['Normal mode sample bit time (us)', 15],
- 'cnt_normal_slot': ['Normal mode data slot time (us)', 60],
- 'cnt_normal_presence': ['Normal mode sample presence time (us)', 75],
- 'cnt_normal_reset': ['Normal mode reset time (us)', 480],
- 'cnt_overdrive_bit': ['Overdrive mode sample bit time (us)', 2],
- # 'cnt_overdrive_slot': ['Overdrive mode data slot time (us)', 7.3],
- 'cnt_overdrive_slot': ['Overdrive mode data slot time (us)', 7],
- 'cnt_overdrive_presence': ['Overdrive mode sample presence time (us)', 10],
- 'cnt_overdrive_reset': ['Overdrive mode reset time (us)', 48],
- }
- annotations = [
- ['bit', 'Bit'],
- ['warnings', 'Warnings'],
- ['reset', 'Reset/presence'],
- ['overdrive', 'Overdrive mode notifications'],
- ]
+ {'id': 'cnt_normal_bit',
+ 'desc': 'Normal mode sample bit time (μs)', 'default': 15},
+ {'id': 'cnt_normal_slot',
+ 'desc': 'Normal mode data slot time (μs)', 'default': 60},
+ {'id': 'cnt_normal_presence',
+ 'desc': 'Normal mode sample presence time (μs)', 'default': 75},
+ {'id': 'cnt_normal_reset',
+ 'desc': 'Normal mode reset time (μs)', 'default': 480},
+ {'id': 'cnt_overdrive_bit',
+ 'desc': 'Overdrive mode sample bit time (μs)', 'default': 2},
+ {'id': 'cnt_overdrive_slot',
+ 'desc': 'Overdrive mode data slot time (μs)', 'default': 7.3},
+ {'id': 'cnt_overdrive_presence',
+ 'desc': 'Overdrive mode sample presence time (μs)', 'default': 10},
+ {'id': 'cnt_overdrive_reset',
+ 'desc': 'Overdrive mode reset time (μs)', 'default': 48},
+ )
+ annotations = (
+ ('bit', 'Bit'),
+ ('warnings', 'Warnings'),
+ ('reset', 'Reset'),
+ ('presence', 'Presence'),
+ ('overdrive', 'Overdrive mode notifications'),
+ )
+ annotation_rows = (
+ ('bits', 'Bits', (0, 2, 3)),
+ ('info', 'Info', (4,)),
+ ('warnings', 'Warnings', (1,)),
+ )
def putm(self, data):
self.put(0, 0, self.out_ann, data)
def putpb(self, data):
- self.put(self.fall, self.samplenum, self.out_proto, data)
+ self.put(self.fall, self.samplenum, self.out_python, data)
def putb(self, data):
self.put(self.fall, self.samplenum, self.out_ann, data)
def putx(self, data):
self.put(self.fall, self.cnt_bit[self.overdrive], self.out_ann, data)
+ def putfr(self, data):
+ self.put(self.fall, self.rise, self.out_ann, data)
+
+ def putprs(self, data):
+ self.put(self.rise, self.samplenum, self.out_python, data)
+
+ def putrs(self, data):
+ self.put(self.rise, self.samplenum, self.out_ann, data)
+
def __init__(self, **kwargs):
+ self.samplerate = None
self.samplenum = 0
self.state = 'WAIT FOR FALLING EDGE'
self.present = 0
self.fall = 0
self.rise = 0
- def start(self, metadata):
- self.out_proto = self.add(srd.OUTPUT_PROTO, 'onewire_link')
- self.out_ann = self.add(srd.OUTPUT_ANN, 'onewire_link')
-
- self.samplerate = metadata['samplerate']
+ def start(self):
+ self.out_python = self.register(srd.OUTPUT_PYTHON)
+ self.out_ann = self.register(srd.OUTPUT_ANN)
+ def checks(self):
# Check if samplerate is appropriate.
- if self.options['overdrive']:
+ if self.options['overdrive'] == 'yes':
if self.samplerate < 2000000:
self.putm([1, ['Sampling rate is too low. Must be above ' +
'2MHz for proper overdrive mode decoding.']])
if self.samplerate < 400000:
self.putm([1, ['Sampling rate is too low. Must be above ' +
'400kHz for proper normal mode decoding.']])
- elif (self.samplerate < 1000000):
+ elif self.samplerate < 1000000:
self.putm([1, ['Sampling rate is suggested to be above ' +
'1MHz for proper normal mode decoding.']])
- # The default 1-Wire time base is 30us. This is used to calculate
- # sampling times.
- samplerate = float(self.samplerate)
-
- x = float(self.options['cnt_normal_bit']) / 1000000.0
- self.cnt_normal_bit = int(samplerate * x) - 1
- x = float(self.options['cnt_normal_slot']) / 1000000.0
- self.cnt_normal_slot = int(samplerate * x) - 1
- x = float(self.options['cnt_normal_presence']) / 1000000.0
- self.cnt_normal_presence = int(samplerate * x) - 1
- x = float(self.options['cnt_normal_reset']) / 1000000.0
- self.cnt_normal_reset = int(samplerate * x) - 1
- x = float(self.options['cnt_overdrive_bit']) / 1000000.0
- self.cnt_overdrive_bit = int(samplerate * x) - 1
- x = float(self.options['cnt_overdrive_slot']) / 1000000.0
- self.cnt_overdrive_slot = int(samplerate * x) - 1
- x = float(self.options['cnt_overdrive_presence']) / 1000000.0
- self.cnt_overdrive_presence = int(samplerate * x) - 1
- x = float(self.options['cnt_overdrive_reset']) / 1000000.0
- self.cnt_overdrive_reset = int(samplerate * x) - 1
-
- # Organize values into lists.
- self.cnt_bit = [self.cnt_normal_bit, self.cnt_overdrive_bit]
- self.cnt_presence = [self.cnt_normal_presence, self.cnt_overdrive_presence]
- self.cnt_reset = [self.cnt_normal_reset, self.cnt_overdrive_reset]
- self.cnt_slot = [self.cnt_normal_slot, self.cnt_overdrive_slot]
-
# Check if sample times are in the allowed range.
time_min = float(self.cnt_normal_bit) / self.samplerate
if (time_min < 0.0000073) or (time_max > 0.000010):
self.putm([1, ['The overdrive mode presence sample time interval ' +
'(%2.1fus-%2.1fus) should be inside (7.3us, 10.0us).'
- % (time_min*1000000, time_max*1000000)]])
+ % (time_min * 1000000, time_max * 1000000)]])
+
+
+ def metadata(self, key, value):
+ if key != srd.SRD_CONF_SAMPLERATE:
+ return
+ self.samplerate = value
- def report(self):
- pass
+ # The default 1-Wire time base is 30us. This is used to calculate
+ # sampling times.
+ samplerate = float(self.samplerate)
+
+ x = float(self.options['cnt_normal_bit']) / 1000000.0
+ self.cnt_normal_bit = int(samplerate * x) - 1
+ x = float(self.options['cnt_normal_slot']) / 1000000.0
+ self.cnt_normal_slot = int(samplerate * x) - 1
+ x = float(self.options['cnt_normal_presence']) / 1000000.0
+ self.cnt_normal_presence = int(samplerate * x) - 1
+ x = float(self.options['cnt_normal_reset']) / 1000000.0
+ self.cnt_normal_reset = int(samplerate * x) - 1
+ x = float(self.options['cnt_overdrive_bit']) / 1000000.0
+ self.cnt_overdrive_bit = int(samplerate * x) - 1
+ x = float(self.options['cnt_overdrive_slot']) / 1000000.0
+ self.cnt_overdrive_slot = int(samplerate * x) - 1
+ x = float(self.options['cnt_overdrive_presence']) / 1000000.0
+ self.cnt_overdrive_presence = int(samplerate * x) - 1
+ x = float(self.options['cnt_overdrive_reset']) / 1000000.0
+ self.cnt_overdrive_reset = int(samplerate * x) - 1
+
+ # Organize values into lists.
+ self.cnt_bit = [self.cnt_normal_bit, self.cnt_overdrive_bit]
+ self.cnt_presence = [self.cnt_normal_presence, self.cnt_overdrive_presence]
+ self.cnt_reset = [self.cnt_normal_reset, self.cnt_overdrive_reset]
+ self.cnt_slot = [self.cnt_normal_slot, self.cnt_overdrive_slot]
def decode(self, ss, es, data):
+ if not self.samplerate:
+ raise SamplerateError('Cannot decode without samplerate.')
for (self.samplenum, (owr, pwr)) in data:
+ if self.samplenum == 0:
+ self.checks()
# State machine.
if self.state == 'WAIT FOR FALLING EDGE':
# The start of a cycle is a falling edge.
self.state = 'WAIT FOR RISING EDGE'
continue
- self.putb([0, ['Bit: %d' % self.bit]])
+ self.putb([0, ['Bit: %d' % self.bit, '%d' % self.bit]])
self.putpb(['BIT', self.bit])
# Checking the first command to see if overdrive mode
if self.bit_cnt <= 8:
self.command |= (self.bit << self.bit_cnt)
elif self.bit_cnt == 8 and self.command in [0x3c, 0x69]:
- self.putx([3, ['Entering overdrive mode']])
+ self.putx([4, ['Entering overdrive mode', 'Overdrive on']])
# Increment the bit counter.
self.bit_cnt += 1
# Wait for next slot.
# Check if this was a reset cycle.
t = self.samplenum - self.fall
if t > self.cnt_normal_reset:
- # Save the sample number for the falling edge.
+ # Save the sample number for the rising edge.
self.rise = self.samplenum
+ self.putfr([2, ['Reset', 'Rst', 'R']])
self.state = 'WAIT FOR PRESENCE DETECT'
# Exit overdrive mode.
if self.overdrive:
- self.putx([3, ['Exiting overdrive mode']])
+ self.putx([4, ['Exiting overdrive mode', 'Overdrive off']])
self.overdrive = 0
# Clear command bit counter and data register.
self.bit_cnt = 0
self.command = 0
elif (t > self.cnt_overdrive_reset) and self.overdrive:
- # Save the sample number for the falling edge.
+ # Save the sample number for the rising edge.
self.rise = self.samplenum
- self.state = "WAIT FOR PRESENCE DETECT"
+ self.putfr([2, ['Reset', 'Rst', 'R']])
+ self.state = 'WAIT FOR PRESENCE DETECT'
# Otherwise this is assumed to be a data bit.
else:
- self.state = "WAIT FOR FALLING EDGE"
+ self.state = 'WAIT FOR FALLING EDGE'
elif self.state == 'WAIT FOR PRESENCE DETECT':
# Sample presence status.
t = self.samplenum - self.rise
continue
p = 'false' if self.present else 'true'
- self.putb([2, ['Reset/presence: %s' % p]])
- self.putpb(['RESET/PRESENCE', not self.present])
+ self.putrs([3, ['Presence: %s' % p, 'Presence', 'Pres', 'P']])
+ self.putprs(['RESET/PRESENCE', not self.present])
# Wait for next slot.
self.state = 'WAIT FOR FALLING EDGE'
- else:
- raise Exception('Invalid state: %s' % self.state)