The following drivers/devices require a firmware upload upon connection:
+ - asix-omega-rtm-cli: There is no native sigrok support for ASIX OMEGA
+ devices. But the vendor's RTM CLI application can be used in streaming
+ mode, which transparently handles the device detection and firmware
+ download. The firmware ships with the vendor application. See below
+ for details how to make the vendor application available to the sigrok
+ driver.
+
- asix-sigma: The ASIX SIGMA and SIGMA2 require various firmware files,
depending on the settings used. These files are available from our
'sigrok-firmware' repository/project under a license which allows us
- atten-pps3xxx
- baylibre-acme
- beaglelogic
- - brymen-dmm
- cem-dt-885x
- center-3xx (including all subdrivers)
- chronovu-la
- pce-322a
- pipistrello-ols
- rdtech-dps
+ - rigol-dg
- rigol-ds
- rohde-schwarz-sme-0x
- scpi-dmm
$ sigrok-cli --driver <somedriver>:conn=vxi/<ipaddr> ...
$ sigrok-cli --driver <somedriver>:conn=usbtmc/<bus>.<addr> ...
+Individual device drivers _may_ implement additional semantics for the
+conn= specification, which would not apply to other drivers, yet can be
+rather useful for a given type of device.
+
+ $ sigrok-cli --driver <somedriver>:conn=sn=<serno>
+
Specifying serial port parameters
---------------------------------
Please consult the udev docs for details.
+Non-default drivers for commodity chips
+---------------------------------------
+
+Some vendors include common USB chips in their products yet assign device
+specific VID:PID pairs. Which results in the necessity for extra steps
+before the serial port can be used:
+
+- GW Instek VCP, found in GDM-8000 and probably other meters: Install the
+ vendors Windows driver to get access to a COM port. Or force the driver
+ assignment on Linux:
+ # modprobe cp210x
+ # echo 2184 0030 > /sys/bus/usb-serial/drivers/cp210x/new_id
+
+
Cypress FX2 based devices
-------------------------
'SI232 online' (28-29S) or 'SI232 store' (22-26x). The interface must
be configured to the same baud rate as the host (default 9600).
Multimeter and interface must be configured to the same address.
+ - GW Instek GDM-397: Press the "REL/RS232C (USB)" button for roughly 1 second.
+ - GW Instek VCP: See the discussion on manual driver assignment to common
+ USB to UART chips with non-default USB identification.
- MASTECH MS6514: Press the "Setup/PC-Link" button for roughly 3 seconds.
+ - Meterman 38XR: Press the "RS232" button.
- Metrix MX56C: Press the PRINT button to have the meter send acquisition
data via IR. Hold the PRINT button to adjust the meter's transmission
interval.
- Voltcraft VC-870: Press the "REL/PC" button for roughly 1 second.
+ASIX OMEGA in RTM CLI mode
+--------------------------
+
+The asix-sigma driver can detect the Omega devices' presence, but does
+not support their protocol and emits a diagnostics message. The firmware
+image is not available for distribution, and information on the protocol
+is not available. That's why native support is in some distant future.
+Yet basic operation of Omega devices is available by using the vendor's
+command line application for real time mode (RTM CLI).
+
+The vendor application targets Windows (on x86), but also executes on
+Linux when 32bit libraries for FTDI communication are provided. The
+user manual discusses the installation. The sigrok asix-omega-rtm-cli
+driver uses the vendor provided omegartmcli.exe binary to configure the
+device for streaming, and to acquire sample data.
+
+Either make an "omegartmcli" executable available in PATH. This can be
+the vendor's executable or some wrapper around it or a symlink to it.
+Or specify the executable's location in the OMEGARTMCLI environment
+variable. The sigrok driver accepts an optional serial number (six or
+eight hex digits) to select one out of several connected devices.
+
+ (optional)
+ $ export "OMEGARTMCLI=$HOME/.wine/drive_c/progx86/ASIX/SIGMA/omegartmcli.exe"
+
+ (optional)
+ $ OMEGASN=":conn=sn=a6030123"
+
+ (example use)
+ $ sigrok-cli -d asix-omega-rtm-cli${OMEGASN} --show
+ $ sigrok-cli -d asix-omega-rtm-cli${OMEGASN} -o capture.sr --time 10s
+ $ sigrok-cli -d asix-omega-rtm-cli${OMEGASN} -o capture.sr --samples 100m
+ $ pulseview -d asix-omega-rtm-cli${OMEGASN}
+
+The RTM mode of operation samples 16 channels at a fixed rate of 200MHz.
+Hardware triggers are not available in this mode. Glib should handle
+platform specific details of external process execution, but the driver
+was only tested on Linux so far. Acquisition start in sigrok applications
+may take some time before sample data becomes available (roughly one
+second here on a slow machine). This is an implementation detail of the
+RTM CLI approach including execution under wine.
+
+The reliability of that setup in the presence of fast changing input
+signals is yet to get determined. It's assumed that slow input signals
+are operational. It's essential that the _average_ rate of changes in
+the input signal in combination with the hardware compression are such
+that the FTDI FIFO can communicate all involved data via USB2.0 to the
+application. Intermediate bursts of rapid changes shall not be an issue
+given the Omega devices' deep memory which RTM uses for buffering.
+
+Native support for the Asix Omega devices depends on the availability of
+a protocol description and use of the protocol depends on the firmware's
+availability at the user's site. Which then would allow to capture to
+DRAM at high rates without the communication bottleneck, before the data
+gets communicated to the PC after the acquisition has completed. Compare
+the native sigrok support for Asix Sigma.
+
+
ChronoVu LA8/LA16 USB VID/PIDs
------------------------------
$ sigrok-cli --driver ols:conn=/dev/ttyACM0 ...
+JTAGulator
+----------
+
+The Grand Idea Studio JTAGulator also implements the SUMP protocol and
+thus is covered by the OLS driver. See the vendor's wiki on details how
+to enable the Logic Analyzer mode of operation.
+
+ https://github.com/grandideastudio/jtagulator/wiki/Logic-Analyzer
+
+
Mooshimeter
-----------