Commit | Line | Data |
---|---|---|
1 | ------------------------------------------------------------------------------- | |
2 | README.devices | |
3 | ------------------------------------------------------------------------------- | |
4 | ||
5 | This README contains various notes for users of libsigrok (or frontends | |
6 | that are based on libsigrok) about device- and/or driver-specific issues. | |
7 | ||
8 | ||
9 | Firmware | |
10 | -------- | |
11 | ||
12 | Some devices supported by libsigrok need a firmware to be uploaded every time | |
13 | the device is connected to the PC (usually via USB), before it can be used. | |
14 | ||
15 | The default locations where libsigrok expects the firmware files are: | |
16 | ||
17 | $HOME/.local/share/sigrok-firmware | |
18 | $prefix/share/sigrok-firmware | |
19 | /usr/local/share/sigrok-firmware | |
20 | /usr/share/sigrok-firmware | |
21 | ||
22 | ($prefix is usually /usr/local or /usr, depending on your ./configure options) | |
23 | ||
24 | For further information see the section below and also: | |
25 | ||
26 | http://sigrok.org/wiki/Firmware | |
27 | ||
28 | ||
29 | Per-driver firmware requirements | |
30 | -------------------------------- | |
31 | ||
32 | The following drivers/devices require a firmware upload upon connection: | |
33 | ||
34 | - asix-sigma: The ASIX SIGMA and SIGMA2 require various firmware files, | |
35 | depending on the settings used. These files are available from our | |
36 | 'sigrok-firmware' repository/project under a license which allows us | |
37 | to redistribute them. | |
38 | ||
39 | - fx2lafw: Logic analyzers based on the Cypress FX2(LP) chip need the | |
40 | firmware files from the 'sigrok-firmware-fx2lafw' repository/project. | |
41 | The firmware is written from scratch and licensed under the GNU GPLv2+. | |
42 | ||
43 | - hantek-6xxx: Certain oscilloscopes based on the Cypress FX2(LP) chip, | |
44 | such as the Hantek 6022BE and SainSmart DDS120, need the | |
45 | firmware files from the 'sigrok-firmware-fx2lafw' repository/project. | |
46 | The firmware is written from scratch and licensed under the GNU GPLv2+. | |
47 | ||
48 | - hantek-dso: The Hantek DSO-2090 (and other supported models of the same | |
49 | series of Hantek PC oscilloscopes) need firmware files. | |
50 | These can be extracted from the vendor's Windows drivers using a tool | |
51 | from our 'sigrok-util' repository/project. | |
52 | ||
53 | - lecroy-logicstudio: The LeCroy LogicStudio requires FPGA bitstream files. | |
54 | These can be extracted from the vendor's Windows software using a tool | |
55 | from our 'sigrok-util' repository/project. | |
56 | Additionally, it requires a Cypress FX2 firmware. This can be extracted | |
57 | from the vendor's Windows software using another tool. Details: | |
58 | ||
59 | http://sigrok.org/wiki/LeCroy_LogicStudio#Firmware | |
60 | ||
61 | - saleae-logic16: The Saleae Logic16 needs a firmware file for the | |
62 | Cypress FX2 chip in the device, as well as two FPGA bitstream files. | |
63 | These can be extracted from the vendor's Linux application using a tool | |
64 | from our 'sigrok-util' repository/project. | |
65 | ||
66 | - sysclk-lwla: | |
67 | ||
68 | - The Sysclk LWLA1034 requires various bitstream files. | |
69 | These files are available from our 'sigrok-firmware' repository/project | |
70 | under a license which allows us to redistribute them. | |
71 | ||
72 | - The Sysclk LWLA1016 requires various bitstream files. | |
73 | These can be extracted from the vendor's Windows drivers using a tool | |
74 | from our 'sigrok-util' repository/project. | |
75 | ||
76 | The following drivers/devices do not need any firmware upload: | |
77 | ||
78 | - agilent-dmm | |
79 | - appa-55ii | |
80 | - arachnid-labs-re-load-pro | |
81 | - atten-pps3xxx | |
82 | - baylibre-acme | |
83 | - beaglelogic | |
84 | - brymen-bm86x | |
85 | - brymen-dmm | |
86 | - cem-dt-885x | |
87 | - center-3xx (including all subdrivers) | |
88 | - chronovu-la | |
89 | - colead-slm | |
90 | - conrad-digi-35-cpu | |
91 | - demo | |
92 | - deree-de5000 | |
93 | - fluke-dmm | |
94 | - ftdi-la | |
95 | - gmc-mh-1x-2x (including all subdrivers) | |
96 | - gwinstek-gds-800 | |
97 | - hameg-hmo | |
98 | - hp-3457a | |
99 | - hung-chang-dso-2100 | |
100 | - ikalogic-scanalogic2 | |
101 | - ikalogic-scanaplus | |
102 | - kecheng-kc-330b | |
103 | - kern-scale | |
104 | - lascar-el-usb | |
105 | - link-mso19 | |
106 | - manson-hcs-3xxx | |
107 | - maynuo-m97 | |
108 | - mic-985xx (including all subdrivers) | |
109 | - motech-lps-30x | |
110 | - norma-dmm | |
111 | - openbench-logic-sniffer | |
112 | - pce-322a | |
113 | - pipistrello-ols | |
114 | - rigol-ds | |
115 | - scpi-pps | |
116 | - serial-dmm (including all subdrivers) | |
117 | - teleinfo | |
118 | - testo | |
119 | - tondaj-sl-814 | |
120 | - uni-t-dmm (including all subdrivers) | |
121 | - uni-t-ut32x | |
122 | - victor-dmm | |
123 | - yokogawa-dlm | |
124 | - zeroplus-logic-cube | |
125 | ||
126 | ||
127 | Specifying serial ports | |
128 | ----------------------- | |
129 | ||
130 | Many devices supported by libsigrok use serial port based cables (real RS232 | |
131 | or USB-to-serial ones) to connect to a PC. | |
132 | ||
133 | For all these devices, you need to specify the serial port they are connected | |
134 | to (e.g. using the 'conn' option in sigrok-cli). It is not possible to scan | |
135 | for such devices without specifying a serial port. | |
136 | ||
137 | Example: | |
138 | ||
139 | $ sigrok-cli --driver <somedriver>:conn=/dev/ttyUSB0 ... | |
140 | ||
141 | The following drivers/devices require a serial port specification: | |
142 | ||
143 | - agilent-dmm | |
144 | - appa-55ii | |
145 | - atten-pps3xxx | |
146 | - brymen-dmm | |
147 | - cem-dt-885x | |
148 | - center-3xx (including all subdrivers) | |
149 | - colead-slm | |
150 | - conrad-digi-35-cpu | |
151 | - fluke-dmm | |
152 | - gmc-mh-1x-2x (including all subdrivers) | |
153 | - hameg-hmo | |
154 | - link-mso19 | |
155 | - mic-985xx (including all subdrivers) | |
156 | - norma-dmm | |
157 | - openbench-logic-sniffer | |
158 | - rigol-ds (for RS232; not required for USBTMC or TCP) | |
159 | - serial-dmm (including all subdrivers) | |
160 | - teleinfo | |
161 | - tondaj-sl-814 | |
162 | ||
163 | The following drivers/devices do not require a serial port specification: | |
164 | ||
165 | - asix-sigma | |
166 | - brymen-bm86x | |
167 | - chronovu-la | |
168 | - demo | |
169 | - fx2lafw | |
170 | - hantek-dso | |
171 | - ikalogic-scanalogic2 | |
172 | - ikalogic-scanaplus | |
173 | - kecheng-kc-330b | |
174 | - lascar-el-usb | |
175 | - pipistrello-ols | |
176 | - rigol-ds (USBTMC or TCP) | |
177 | - saleae-logic16 | |
178 | - sysclk-lwla | |
179 | - uni-t-dmm (including all subdrivers) | |
180 | - uni-t-ut32x | |
181 | - victor-dmm | |
182 | - yokogawa-dlm (USBTMC or TCP) | |
183 | - zeroplus-logic-cube | |
184 | ||
185 | ||
186 | Specifying serial port parameters | |
187 | --------------------------------- | |
188 | ||
189 | Every serial device's driver has default serial port parameters like baud | |
190 | rate, number of data bits, stop bits and handshake status. If a device requires | |
191 | different parameters, pass them as option "serialcomm" with the driver name. | |
192 | See libsigrok docs for the function serial_set_paramstr() for complete specs. | |
193 | ||
194 | Example: | |
195 | ||
196 | $ sigrok-cli --driver <somedriver>:conn=<someconn>:serialcomm=9600/7n1/dtr=1 | |
197 | ||
198 | ||
199 | Permissions of serial port based devices | |
200 | ---------------------------------------- | |
201 | ||
202 | When using devices supported by libsigrok that use serial port based cables | |
203 | (real RS232 or USB-to-serial ones) to connect to a PC, you need to ensure | |
204 | that the user running the libsigrok frontend has (read/write) permissions to | |
205 | access the serial port device (e.g. /dev/ttyS0, /dev/ttyUSB0, and so on). | |
206 | ||
207 | You can use 'chmod' to apply permissions as you see fit, and/or 'chown' to | |
208 | change the owner of the serial port device to a certain user or group. | |
209 | ||
210 | For USB-to-serial based devices, we recommended using our udev rules file | |
211 | (see below for details). | |
212 | ||
213 | ||
214 | Permissions for USB devices (udev rules file) | |
215 | --------------------------------------------- | |
216 | ||
217 | When using USB-based devices supported by libsigrok, the user running the | |
218 | libsigrok frontend (e.g. sigrok-cli) has to have (read/write) permissions | |
219 | for the respective USB device. | |
220 | ||
221 | On Linux, this is accomplished using either 'chmod' (not recommended) or | |
222 | using the udev rules file shipped with libsigrok (recommended). | |
223 | ||
224 | The file is available in contrib/z60_libsigrok.rules. It contains entries | |
225 | for all libsigrok-supported (USB-based) devices and changes their group | |
226 | to 'plugdev' and the permissions to '664'. | |
227 | ||
228 | When using a libsigrok package from your favorite Linux distribution, the | |
229 | packager will have already taken care of properly installing the udev file | |
230 | in the correct (distro-specific) place, and you don't have to do anything. | |
231 | The packager might also have adapted 'plugdev' and '664' as needed. | |
232 | ||
233 | If you're building from source, you need to copy the file to the place | |
234 | where your distro expects such files. This is beyond the scope of this README, | |
235 | but generally the location could be e.g. /etc/udev/rules.d, or maybe | |
236 | /lib/udev/rules.d, or something else. Afterwards you might have to restart | |
237 | udev, e.g. via '/etc/init.d/udev restart' or similar, and you'll have to | |
238 | re-attach your device via USB. | |
239 | ||
240 | Please consult the udev docs of your distro for details. | |
241 | ||
242 | ||
243 | Cypress FX2 based devices | |
244 | ------------------------- | |
245 | ||
246 | Devices using the Cypress FX2(LP) chip without any specific USB VID/PID will | |
247 | be enumerated with VID/PID 04b4:8613 (the default for "unconfigured FX2"). | |
248 | These are usually "FX2 eval boards" (that can also be used as LAs, though). | |
249 | ||
250 | On Linux, the 'usbtest' driver will usually grab such devices, and they will | |
251 | thus not be usable by libsigrok (and frontends). | |
252 | ||
253 | You can fix this by running 'rmmod usbtest' as root before using the device. | |
254 | ||
255 | ||
256 | UNI-T DMM (and rebranded models) cables | |
257 | --------------------------------------- | |
258 | ||
259 | UNI-T multimeters (and rebranded devices, e.g. some Voltcraft models) can | |
260 | ship with different PC connectivity cables: | |
261 | ||
262 | - UT-D04 (USB/HID cable with Hoitek HE2325U chip, USB VID/PID 04fa:2490) | |
263 | - UT-D04 (USB/HID cable with WCH CH9325 chip, USB VID/PID 1a86:e008) | |
264 | - UT-D02 (RS232 cable) | |
265 | ||
266 | The above cables are all physically compatible (same IR connector shape) | |
267 | with all/most currently known UNI-T multimeters. For example, you can | |
268 | use either of the UT-D04 USB/HID cables or the UT-D02 RS232 cable with | |
269 | the UNI-T UT61D multimeter. | |
270 | ||
271 | When using the UT-D02 RS232 cable with any of the supported UNI-T DMMs, | |
272 | you have to use the respective driver with a '-ser' drivername suffix | |
273 | (internally all of these models are handled by the 'serial-dmm' driver). | |
274 | ||
275 | You also need to specify the serial port via the 'conn' option, e.g. | |
276 | /dev/ttyUSB0 (attached via a USB-to-serial cable) or /dev/ttyS0 (actual | |
277 | RS232 port) on Linux (see above). | |
278 | ||
279 | Finally, the user running the frontend (e.g. sigrok-cli) also needs | |
280 | permissions to access the respective serial port (see above). | |
281 | ||
282 | Examples (sigrok-cli): | |
283 | ||
284 | $ sigrok-cli --driver uni-t-ut61e-ser:conn=/dev/ttyUSB0 ... | |
285 | $ sigrok-cli --driver voltcraft-vc820-ser:conn=/dev/ttyS0 ... | |
286 | ||
287 | When using any of the UT-D04 USB/HID cables you have to use the respective | |
288 | driver _without_ the '-ser' drivername suffix (internally all of these models | |
289 | are handled by the 'uni-t-dmm' driver). | |
290 | ||
291 | You also need to specify the USB vendor/device IDs of the cable. | |
292 | Autodetection is not possible here, since various other products use the | |
293 | USB VID/PID of those cables too, and there is no way to distinguish them. | |
294 | ||
295 | Since the UT-D04 cables are USB based (but don't use a USB-to-serial chip) | |
296 | there is no need to specify a serial port via 'conn', of course. | |
297 | However, the user running the frontend does also need to have permissions | |
298 | to access the respective USB device (see above). | |
299 | ||
300 | Examples (sigrok-cli): | |
301 | ||
302 | $ sigrok-cli --driver uni-t-ut61e:conn=1a86.e008 ... | |
303 | $ sigrok-cli --driver voltcraft-vc820:conn=04fa.2490 ... | |
304 | ||
305 | ||
306 | UNI-T UT-D04 cable issue on Linux | |
307 | --------------------------------- | |
308 | ||
309 | The UNI-T UT-D04 cable with Hoitek HE2325U (or WCH CH9325) chip seems to have | |
310 | a very specific problem on Linux. Apparently it requires to be put into | |
311 | suspend (and woken up again) before it is usable. This seems to be a | |
312 | Linux-only issue, Windows is not affected by this since apparently the | |
313 | Windows kernel does this for every USB device, always. | |
314 | ||
315 | Thus, if you want to use any of the UNI-T DMMs with this specific cable, | |
316 | you'll have to run the following script (as root) once, every time you attach | |
317 | the cable via USB. The script was written by Ralf Burger. | |
318 | ||
319 | See also: http://erste.de/UT61/index.html | |
320 | ||
321 | #!/bin/bash | |
322 | for dat in /sys/bus/usb/devices/*; do | |
323 | if test -e $dat/manufacturer; then | |
324 | grep "WCH.CN" $dat/manufacturer > /dev/null && echo auto > ${dat}/power/level && echo 0 > ${dat}/power/autosuspend | |
325 | fi | |
326 | done | |
327 | ||
328 | ||
329 | Enabling multimeter / data logger measurement output | |
330 | ---------------------------------------------------- | |
331 | ||
332 | Some multimeters or data loggers will not start outputting measurement data | |
333 | unless a certain action has been performed by the user beforehand. This is | |
334 | usually mentioned in the vendor manual of the respective device, but here's | |
335 | a short list for convenience: | |
336 | ||
337 | - BBC Goertz Metrawatt M2110: Briefly press the "Start/Reset" button on the | |
338 | interface panel on top. | |
339 | - Digitek DT4000ZC: Briefly press the "RS232" button. | |
340 | - Gossen Metrawatt Metrahit 1x/2x devices, driver gmc-mh-1x-2x-rs232: | |
341 | - Power on the device with the "DATA" button pressed. | |
342 | - Metrahit 2x devices must be configured for the respective interface type. | |
343 | - Gossen Metrawatt Metrahit 2x devices, driver gmc-mh-2x-bd232: | |
344 | - 'BD232' interface: | |
345 | The multimeter must be configured for the respective interface type. | |
346 | - 'SI232-II' interface ("PC Mode"): | |
347 | The multimeter must be configured for interface type 'BD232' (all), | |
348 | 'SI232 online' (28-29S) or 'SI232 store' (22-26x). The interface must | |
349 | be configured to the same baud rate as the host (default 9600). | |
350 | Multimeter and interface must be configured to the same address. | |
351 | - Norma DM950: If the interface doesn't work (e.g. USB-RS232 converter), power | |
352 | on the device with "FUNC" pressed (to power the interface from the DMM). | |
353 | - PCE PCE-DM32: Briefly press the "RS232" button. | |
354 | - RadioShack 22-812: Press and hold "SELECT" and "RANGE" together. | |
355 | - TekPower TP4000ZC: Briefly press the "RS232" button. | |
356 | - Tenma 72-7750: Briefly press the "RS232C" button. | |
357 | - UNI-T UT60G: Briefly press the "RS232C" button. | |
358 | - UNI-T UT61B/C/D: Press the "REL/RS232/USB" button for roughly 1 second. | |
359 | - UNI-T UT71x: Press the "SEND/-/MAXMIN" button for roughly 1 second. | |
360 | Briefly pressing the "EXIT" button leaves this mode again. | |
361 | - UNI-T UT325: Briefly press the "SEND" button (as per manual). However, it | |
362 | appears that in practice you don't have to press the button (at least on | |
363 | some versions of the device), simply connect the device via USB. | |
364 | - V&A VA18B/VA40B: Keep the "Hz/DUTY" key pressed while powering on the DMM. | |
365 | - Victor 70C/86C: Press the "REL/RS232" button for roughly 1 second. | |
366 | - Voltcraft VC-830: Press the "REL/PC" button for roughly 2 seconds. | |
367 | - Voltcraft VC-870: Press the "REL/PC" button for roughly 1 second. | |
368 | ||
369 | ||
370 | ChronoVu LA8/LA16 USB VID/PIDs | |
371 | ------------------------------ | |
372 | ||
373 | The ChronoVu LA8/LA16 logic analyzer is available in two revisions. Previously, | |
374 | the device shipped with a USB VID/PID of 0403:6001, which is the standard ID | |
375 | for FTDI FT232 USB chips. | |
376 | ||
377 | Since this made it hard to distinguish the LA8/LA16 from any other device | |
378 | with this FTDI chip connected to the PC, the vendor later shipped the | |
379 | device with a USB VID/PID of 0403:8867. | |
380 | ||
381 | The 'chronovu-la' driver in libsigrok supports both VID/PID pairs and | |
382 | automatically finds devices with either VID/PID pair. | |
383 | ||
384 | ||
385 | OLS | |
386 | --- | |
387 | ||
388 | The Dangerous Prototypes Openbench Logic Sniffer (OLS) logic analyzer | |
389 | driver in libsigrok assumes a somewhat recent firmware has been flashed onto | |
390 | the OLS (it doesn't need a firmware upload every time it's attached via USB, | |
391 | since the firmware is stored in the device permanently). | |
392 | ||
393 | The most recent firmware version that is tested is 3.07. | |
394 | ||
395 | If you use any older firmware and your OLS is not found or is not working | |
396 | properly, please upgrade to at least this firmware version. Check the | |
397 | Dangerous Prototypes wiki for firmware upgrade instructions: | |
398 | ||
399 | http://dangerousprototypes.com/docs/Logic_Sniffer_upgrade_procedure | |
400 | ||
401 | Also, you need to specify a serial port for the OLS in the frontends, e.g. | |
402 | using the 'conn' option in sigrok-cli, and you also need to have the | |
403 | permissions to access the serial port (see above). | |
404 | ||
405 | Example: | |
406 | ||
407 | $ sigrok-cli --driver ols:conn=/dev/ttyACM0 ... | |