While errors are usually already implicitly caught by looking at the packet
length field there is one error status which is worth special handling. If the
device has been removed there is not really a chance to recover from this error
so data acquisition can be stopped immediately.
Signed-off-by: Lars-Peter Clausen <redacted>
{
/* TODO: These statics have to move to the ctx struct. */
static int empty_transfer_count = 0;
{
/* TODO: These statics have to move to the ctx struct. */
static int empty_transfer_count = 0;
+ gboolean packet_has_error = FALSE;
struct sr_datafeed_packet packet;
struct sr_datafeed_logic logic;
struct context *ctx = transfer->user_data;
struct sr_datafeed_packet packet;
struct sr_datafeed_logic logic;
struct context *ctx = transfer->user_data;
const int sample_width = ctx->sample_wide ? 2 : 1;
const int cur_sample_count = transfer->actual_length / sample_width;
const int sample_width = ctx->sample_wide ? 2 : 1;
const int cur_sample_count = transfer->actual_length / sample_width;
- if (transfer->actual_length == 0) {
+ switch (transfer->status) {
+ case LIBUSB_TRANSFER_NO_DEVICE:
+ abort_acquisition(ctx);
+ free_transfer(transfer);
+ return;
+ case LIBUSB_TRANSFER_COMPLETED:
+ case LIBUSB_TRANSFER_TIMED_OUT: /* We may have received some data though */
+ break;
+ default:
+ packet_has_error = TRUE;
+ break;
+ }
+
+ if (transfer->actual_length == 0 || packet_has_error) {
empty_transfer_count++;
if (empty_transfer_count > MAX_EMPTY_TRANSFERS) {
/*
empty_transfer_count++;
if (empty_transfer_count > MAX_EMPTY_TRANSFERS) {
/*