@@ -1,3 +1,39 @@
+------------------
+ * Add firmware for the Instrustar ISDS205B
+
+0.1.7 (2019-11-14)
+------------------
+
+ * Add firmware for the YiXingDianZi MDSO (VID/PID: 1D50:608E).
+ * Sainsmart DDS120: Fix the 1kHz reference signal.
+ * Hantek 6022BL: Fix the voltage range selection (bug #1360).
+ * Allow LA captures at 48MHz samplerate (as long as bus conditions permit).
+ * Updated build requirement: sdcc >= 3.4.0 (bug #1326).
+ * Fix a build issue with sdcc >= 3.9.0 (bug #1404).
+ * Bump the firmware version (major.minor) to 1.4. This version is
+   backwards-compatible and doesn't require host-side (libsigrok) changes.
+
+0.1.6 (2018-01-26)
+------------------
+
+ * Fix an issue with FX2 based logic analyzers that could cause non-working
+   and/or prematurely aborted acquisitions (bug #655).
+ * FX2 based logic analyzers will now toggle pin PA1 during acquisition,
+   and keep it high while idle. On fx2grok-tiny and fx2grok-flat devices
+   there's a LED connected to PA1. Thus, those devices will visually indicate
+   whether a firmware has been uploaded (LED will light up and stay like that
+   while the device is idle). During any acquisition the LED will blink.
+ * Refactor the oscilloscope code to avoid duplication (bug #984).
+ * Fix a 'make distclean' error.
+ * Fix a compiler warning with recent sdcc versions (e.g. v3.6.9).
+
+0.1.5 (2017-06-12)
+------------------
+
+ * Add FX2 firmware for the Hantek 6022BL USB scope/LA.
+ * HACKING: Update URL to Linux kernel coding style.
+ * Remove FSF postal address from boiler plate license text.
+
 0.1.4 (2016-10-31)
 ------------------