Bug 982 - PD related warnings not always shown in PV
Summary: PD related warnings not always shown in PV
Status: RESOLVED FIXED
Alias: None
Product: PulseView
Classification: Unclassified
Component: UI (show other bugs)
Version: unreleased development snapshot
Hardware: All All
: Normal normal
Target Milestone: ---
Assignee: Nobody
URL:
Keywords:
Depends on:
Blocks:
 
Reported: 2017-06-13 18:08 CEST by Uwe Hermann
Modified: 2017-06-17 22:03 CEST (History)
0 users



Attachments

Note You need to log in before you can comment on or make changes to this bug.
Description Uwe Hermann 2017-06-13 18:08:38 CEST
How to reproduce:

 - Start PV, select demo (no acquisition needed), add the SPI decoder.
 - There should be a red "One or more required channels have not been specified" banner in the SPI decode trace, but there is none.
 - Add a new view, then move the right view slowly further to the left (to make the left one smaller). At some point the red banner will now appear in the left view.
Comment 1 Uwe Hermann 2017-06-17 22:03:54 CEST
Fixed in a998be27f155eee556f7ec521e5f70ce692026dc, thanks!