Created attachment 162 [details] sigrok-cli log with 12 and 24 MHz I have a generic FX2LP-based clone logic analyser. It works with sigrok and the fx2lafw firmware up to 12 MHz sampling rate. At higher sample rates (16, 24 MHz), it complains about sampling at 16-bit samples. I know that this is a hardware limitation. I see no way to set the device to 8-bit sampling which should allow 16 and 24 MHz sampling. I am using the latest checkout from master libsigrok 6e799d0 sigrok-firmware-fx2lafw c547f69e The error comes from protocol.c http://sigrok.org/gitweb/?p=libsigrok.git;a=blob;f=src/hardware/fx2lafw/protocol.c;h=12fc9e2c061166405b494ad813c6c704d146d1fe;hb=HEAD#l94 The flag is set from the capabilities and to cannot be changes at runtime. http://sigrok.org/gitweb/?p=libsigrok.git;a=blob;f=src/hardware/fx2lafw/api.c;h=b9123513c49ade9ac38726ad62cd9a0080d19cba;hb=HEAD#l304 I there a way to limit the device to 8-bit sampling to achieve 16 and 24 MHz sampling?
This should work if you only select the lower 8 channels or a subset of these. None of channels 9-16 may be selected. Can you confirm this also works for you? Lowering priority, as it is "only" a UI issue.