Bug 116 - Hantek DSO-2250 fails to trigger on signal
Summary: Hantek DSO-2250 fails to trigger on signal
Status: CONFIRMED
Alias: None
Product: libsigrok
Classification: Unclassified
Component: Driver: hantek-dso (show other bugs)
Version: unreleased development snapshot
Hardware: x86 Linux
: Normal major
Target Milestone: ---
Assignee: Nobody
URL:
Keywords:
Depends on:
Blocks:
 
Reported: 2013-04-30 15:44 CEST by f
Modified: 2013-04-30 15:57 CEST (History)
1 user (show)



Attachments
log level 5 output (389.14 KB, text/plain)
2013-04-30 15:47 CEST, f
Details

Note You need to log in before you can comment on or make changes to this bug.
Description f 2013-04-30 15:44:40 CEST
Using the following command under sigrok-cli starts the dso2250 but the scope fails to trigger (as seen in the log file). The input signal can be any range from 1vpp to 9vpp and the scope still will not trigger. This applies to both channel 1 and channel 2.

/usr/local/bin/sigrok-cli --driver hantek-dso --probes CH1 --frames 1 --device timebase=100us vdiv=500mV triggersource=CH1 coupling=DC -o mytest.txt -O analog -l 5 &> log.txt

mytest.txt is empty. log.txt is attached. The input signal for the log is the 2Vpp @ 1khz calibration signal coming out the scope. Same signal triggers on the opendso software using the same .sys file for extracting the firmware.

all libraries are updated at the time of the bug filing.
 sigrok-cli -V
sigrok-cli 0.3.1
Using libsigrok 0.2.0 (lib version 2:0:0).
Using libsigrokdecode 0.1.1 (lib version 0:1:0).
Comment 1 f 2013-04-30 15:47:12 CEST
Created attachment 34 [details]
log level 5 output