Difference between revisions of "SainSmart DDS120"

From sigrok
Jump to navigation Jump to search
(Initial Sainsmart DDS120 text)
 
(More DDS120 info)
Line 9: Line 9:
or in newer hardware
or in newer hardware
* '''AD''': MXT2088 ([http://www.mxtronics.com/n107/n124/n181/n184/c692/attr/2630.pdf datasheet])
* '''AD''': MXT2088 ([http://www.mxtronics.com/n107/n124/n181/n184/c692/attr/2630.pdf datasheet])
* '''Opamp''': Analog devices AD8065 (OPAMP)
* '''MUX''': Texas Instruments CD4052B (2 x 1:4 MUX)


== Photos ==
== Photos ==
== Protocol ==
 
<gallery>
File:DDS120 Top 20141024 0540p.jpg|<small>Device, top</small>
</gallery>
 
== Vendor Protocol ==


{| border="0" style="font-size: smaller" class="alternategrey sortable sigroktable"
{| border="0" style="font-size: smaller" class="alternategrey sortable sigroktable"
Line 29: Line 36:
|Set sampling rate ||0x94 ||Possible values: 0x11, 0x01, 0x10 (240kHz, 2.4MHz, 48MHz).
|Set sampling rate ||0x94 ||Possible values: 0x11, 0x01, 0x10 (240kHz, 2.4MHz, 48MHz).
|-
|-
|Trigger oscilloscope ||0x33 ||Possible values: 0x00 == start sampling.
|-
|Trigger oscilloscope ||0x60 ||Possible values: 0x00 Generate sine wave.
|-
|Trigger oscilloscope ||0x61 ||Possible values: 0x00 Generate triangle wave.
|-
|Trigger oscilloscope ||0x62 ||Possible values: 0x00 Generate rectangle wave.
|}
|}


Line 37: Line 51:
[[Category:Device]]
[[Category:Device]]
[[Category:Oscilloscope]]
[[Category:Oscilloscope]]
[[Category:UnSupported]]

Revision as of 21:49, 15 March 2016

SainSmart DDS120

The SainSmart DDS120 is a USB-based, 2-channel oscilloscope with an analog bandwidth of 20MS/s and 48MS/s sampling rate.

or in newer hardware

  • AD: MXT2088 (datasheet)
  • Opamp: Analog devices AD8065 (OPAMP)
  • MUX: Texas Instruments CD4052B (2 x 1:4 MUX)

Photos

Vendor Protocol

Oscilloscope command bRequest value Notes
Set CH0 coupling 0x24 Possible values: 0x00, 0x08 (AC-coupling, DC-coupling).
Set CH1 coupling 0x25 Possible values: 0x20, 0x10 (AC-coupling, DC-coupling).
Set CH0 voltage range 0x22 Possible values: 0x08, 0x04, 0x00, 0x06, 0x02 (50mV, 100mV, 200mV, 500mV, 1-5V).
Set CH1 voltage range 0x23 Possible values: 0x20, 0x10, 0x00, 0x12, 0x02 (50mV, 100mV, 200mV, 500mV, 1-5V).
Set sampling rate 0x94 Possible values: 0x11, 0x01, 0x10 (240kHz, 2.4MHz, 48MHz).
Trigger oscilloscope 0x33 Possible values: 0x00 == start sampling.
Trigger oscilloscope 0x60 Possible values: 0x00 Generate sine wave.
Trigger oscilloscope 0x61 Possible values: 0x00 Generate triangle wave.
Trigger oscilloscope 0x62 Possible values: 0x00 Generate rectangle wave.

Resources