== Use == | |||
$ '''sigrok-cli -d scpi-pps --scan''' | |||
The following devices were found: | |||
scpi-pps - ROHDE&SCHWARZ HMP4040 HW50020003/SW2.62 [S/N: 104xxx] with 8 channels: V1 I1 V2 I2 V3 I3 V4 I4 | |||
$ '''sigrok-cli -d scpi-pps --show''' | |||
Driver functions: | |||
Power supply | |||
Scan options: | |||
conn | |||
serialcomm | |||
scpi-pps - ROHDE&SCHWARZ HMP4040 HW50020003/SW2.62 [S/N: 104xxx] with 8 channels: V1 I1 V2 I2 V3 I3 V4 I4 | |||
Channel groups: | |||
1: channels V1 I1 | |||
2: channels V2 I2 | |||
3: channels V3 I3 | |||
4: channels V4 I4 | |||
Supported configuration options across all channel groups: | |||
continuous: on, off | |||
limit_samples: 0 (current) | |||
limit_time: 0 (current) | |||
== Resources == | == Resources == |
Revision as of 09:45, 23 August 2020
Status | in progress |
---|---|
Source code | scpi-pps |
Channels | 3 / 4 |
Voltage/current (CH1) | 0-32V / 0-10A |
Voltage/current (CH2) | 0-32V / 0-10A |
Voltage/current (CH3) | 0-32V / 0-10A |
Voltage/current (CH4) | 0-32V / 0-10A |
Connectivity | USB CDC, USB TMC, LAN |
Website | rohde-schwarz.com |
The Rohde&Schwarz HMP 4000 series consists of the HMP 4030 (3 channels) and HMP 4040 (4 channels) models. Each channel provides up to 32V and up to 10A, with a maximum of 160W per channel, and a maximum of 384W for the total supply. The isolated channels can get connected in series or parallel to get higher voltages or currents. The device ships with USB (CDC and TMC) and LAN by default, GPIB is available as an option.
The HMP 2000 series provides models with fewer channels and lower capabilities.
See Rohde&Schwarz HMP 4040/Info for detailed USB connection information.
Photos
TODO
Use
$ sigrok-cli -d scpi-pps --scan The following devices were found: scpi-pps - ROHDE&SCHWARZ HMP4040 HW50020003/SW2.62 [S/N: 104xxx] with 8 channels: V1 I1 V2 I2 V3 I3 V4 I4
$ sigrok-cli -d scpi-pps --show Driver functions: Power supply Scan options: conn serialcomm scpi-pps - ROHDE&SCHWARZ HMP4040 HW50020003/SW2.62 [S/N: 104xxx] with 8 channels: V1 I1 V2 I2 V3 I3 V4 I4 Channel groups: 1: channels V1 I1 2: channels V2 I2 3: channels V3 I3 4: channels V4 I4 Supported configuration options across all channel groups: continuous: on, off limit_samples: 0 (current) limit_time: 0 (current)
Resources
- vendor's product page (redirects to some localized version)
- EEVBlog episode 1173 forum thread, episode 1174 teardown video