(void)cg;
- if (sdi->status != SR_ST_ACTIVE)
- return SR_ERR_DEV_CLOSED;
-
devc = sdi->priv;
return sr_sw_limits_config_set(&devc->limits, key, data);
struct dev_context *devc;
struct sr_serial_dev_inst *serial;
- if (sdi->status != SR_ST_ACTIVE)
- return SR_ERR_DEV_CLOSED;
-
devc = sdi->priv;
sr_sw_limits_acquisition_start(&devc->limits);
.cleanup = std_cleanup, \
.scan = scan, \
.dev_list = std_dev_list, \
+ .dev_clear = std_dev_clear, \
.config_get = NULL, \
.config_set = config_set, \
.config_list = config_list, \
* Fold marks {{{ }}} with matching braces were added, to further
* speed up navigation in the long list.
*/
+ /* asycii based meters {{{ */
+ DMM(
+ "metrix-mx56c", asycii, "Metrix", "MX56C",
+ "2400/8n1", 2400, ASYCII_PACKET_SIZE, 0, 0, NULL,
+ sr_asycii_packet_valid, sr_asycii_parse, NULL
+ ),
+ /* }}} */
/* bm25x based meters {{{ */
DMM(
"brymen-bm25x", bm25x,
/* dtm0660 based meters {{{ */
DMM(
"peaktech-3415", dtm0660,
- "Peaktech", "3415", "2400/8n1/rts=0/dtr=1",
+ "PeakTech", "3415", "2400/8n1/rts=0/dtr=1",
2400, DTM0660_PACKET_SIZE, 0, 0, NULL,
sr_dtm0660_packet_valid, sr_dtm0660_parse, NULL
),
* "out" by .15%, and so is well within the typical 1% margin
* that is considered acceptable in UART communication, and thus
* should not cause an issue.
+ *
+ * However, using 19230 as baudrate here will not work, as most DMM
+ * cables do not support that baudrate!
*/
DMM(
"tenma-72-7750-ser", es519xx,
),
DMM(
"peaktech-3330", fs9721,
- "Peaktech", "3330", "2400/8n1/dtr=1", 2400,
+ "PeakTech", "3330", "2400/8n1/dtr=1", 2400,
FS9721_PACKET_SIZE, 0, 0, NULL,
sr_fs9721_packet_valid, sr_fs9721_parse,
sr_fs9721_01_10_temp_f_c
),
/* }}} */
/* fs9922 based meters {{{ */
+ DMM(
+ "sparkfun-70c", fs9922,
+ "SparkFun", "70C", "2400/8n1/rts=0/dtr=1",
+ 2400, FS9922_PACKET_SIZE, 0, 0, NULL,
+ sr_fs9922_packet_valid, sr_fs9922_parse, NULL
+ ),
DMM(
"uni-t-ut61b-ser", fs9922,
"UNI-T", "UT61B (UT-D02 cable)", "2400/8n1/rts=0/dtr=1",
&sr_fs9922_z1_diode
),
/* }}} */
- /* metex14 based meters {{{ */
+ /* m2110 based meters {{{ */
DMM(
- "bbcgm-2010", metex14,
+ "bbcgm-2010", m2110,
"BBC Goertz Metrawatt", "M2110", "1200/7n2", 1200,
BBCGM_M2110_PACKET_SIZE, 0, 0, NULL,
sr_m2110_packet_valid, sr_m2110_parse,
NULL
),
+ /* }}} */
+ /* metex14 based meters {{{ */
DMM(
"mastech-mas345", metex14,
"MASTECH", "MAS345", "600/7n2/rts=0/dtr=1", 600,
),
DMM(
"peaktech-3410", metex14,
- "Peaktech", "3410", "600/7n2/rts=0/dtr=1", 600,
+ "PeakTech", "3410", "600/7n2/rts=0/dtr=1", 600,
METEX14_PACKET_SIZE, 0, 0, sr_metex14_packet_request,
sr_metex14_packet_valid, sr_metex14_parse,
NULL