]> sigrok.org Git - libsigrok.git/blame - NEWS
Bump package version to 0.2.1, libtool version to 1:1:0.
[libsigrok.git] / NEWS
CommitLineData
f93c89b2
UH
10.2.1 (2013-08-07)
2------------------
3
4Note: This release does NOT change the libsigrok API. While new config keys,
5 config info types, and error codes have been added (additional enum
6 entries / numbers), no existing interfaces were added/changed/removed.
7 Frontends should continue to work fine without recompiling or relinking.
8
9 * New supported hardware:
10 - Logic analyzers:
11 - IKALOGIC Scanalogic-2
12 - IKALOGIC ScanaPLUS
13 - Sound level meters:
14 - CEM DT-8852
15 - Kecheng KC-330B
16 - Multimeters:
17 - UNI-T UT60A
18 - UNI-T UT60E
19 - Voltcraft M-3650D
20 - Voltcraft VC-830
21 * Drop the Tecpel DMM-8060 (doesn't have PC connectivity).
22 * New config keys:
23 - SR_CONF_SPL_WEIGHT_FREQ
24 - SR_CONF_SPL_WEIGHT_TIME
25 - SR_CONF_SPL_MEASUREMENT_RANGE
26 - SR_CONF_HOLD_MIN
27 - SR_CONF_HOLD_MAX
28 - SR_CONF_POWER_OFF
29 - SR_CONF_DATA_SOURCE
30 * New config info types:
31 - SR_T_UINT64_RANGE
32 * New error codes:
33 - SR_ERR_TIMEOUT
34 * Always link against libm, the math library (bug #115).
35 * Fix a bug in sr_si_string_u64() at al (bug #73).
36 * output/csv: Fix incorrect probe order.
37 * alsa: Fix a double-free issue (bug #129).
38 * zeroplus-logic-cube: Fix a bug in the driver cleanup code.
39 * ikalogic-scanalogic2: Use GET_REPORT (bug #130).
40 * uni-t-dmm: Fix a bug breaking the UNI-T UT61E (bug #136).
41 * Various internal consistency fixes and code cleanups.
42 * Improved Doxygen documentation.
43 * Fixed various memory leaks.
44
048e8bab 450.2.0 (2013-05-04)
0236ab68
UH
46------------------
47
048e8bab
UH
48Note: This release DOES change the libsigrok API. That means it is NOT
49 backwards-compatible and frontends will need updates.
50
115f8293
UH
51 * Support for analog sources (oscilloscopes, DMMs, data loggers) was added.
52 * New supported hardware:
53 - Logic analyzers:
456dfd9f 54 - CWAV USBee DX
115f8293
UH
55 - ZEROPLUS LAP-16128U
56 - Oscilloscopes:
57 - Hantek DSO-2090 (USB scope)
58 - Rigol DS1052D
59 - Rigol DS1052E
60 - Rigol DS1102D
61 - Rigol DS1102E
62 - Multimeters:
63 - Agilent U1231A
64 - Agilent U1232A
65 - Agilent U1233A
66 - Brymen BM857
67 - Digitek DT4000ZC
68 - Fluke 187
69 - Fluke 189
70 - Fluke 287
71 - Fluke 289
048e8bab 72 - Fluke ScopeMeter 199B
115f8293
UH
73 - MASTECH MAS345
74 - Metex ME-31
75 - Metex M-3640D
456dfd9f 76 - PCE PCE-DM32
115f8293
UH
77 - PeakTech 3410
78 - PeakTech 4370
115f8293
UH
79 - RadioShack 22-168
80 - RadioShack 22-805
81 - RadioShack 22-812
456dfd9f
UH
82 - Tecpel DMM-8060
83 - Tecpel DMM-8061
115f8293
UH
84 - TekPower TP4000ZC
85 - UNI-T UT61D
86 - UNI-T UT61E
87 - V&A VA18B
88 - Victor 70C
89 - Victor 86C
90 - Voltcraft VC-820
91 - Voltcraft VC-840
92 - Sound level meters:
93 - Colead SL-5868P
94 - Tondaj SL-814
95 - Temperature/humidity/CO loggers:
96 - Lascar EL-USB and EL-USB CO series (various models)
97 - MIC 98581
98 - MIC 98583
99 * The limitation of max. 64 digital probes has been removed in many places.
100 * Added generic DMM protocol parsers usable for various DMMs, over various
101 cables and/or transports (e.g. same protocol over serial or USB/HID):
102 - Cyrustek ES51922 binary protocol.
103 - Fortune Semiconductor FS9721_LP3/FS9721B binary protocol.
456dfd9f 104 - Fortune Semiconductor FS9922-DMM3/DMM4 binary protocol.
115f8293
UH
105 - Metex 14-byte ASCII protocol.
106 - RadioShack 22-812 binary protocol.
107 * zeroplus-logic-cube driver:
108 - Fix acquisition at some specific samplerates. Only report valid ones.
109 - Default to a samplerate of 1MHz.
110 - Fix trigger code.
111 - Add pre-trigger (capture ratio) setting.
112 - Add support for the ZEROPLUS LAP-16128U.
c9166745 113 * fx2lafw driver:
456dfd9f
UH
114 - Add support for the CWAV USBee DX. This requires the latest version of
115 the fx2lafw firmware files.
115f8293
UH
116 - Add support for wide sampling (i.e. 16 probes instead of just 8).
117 - Fix multi-stage (software) triggers.
118 - Fix various memory leaks, firmware upload timeout bugs, and other issues.
119 - Various performance and memory usage improvements in the driver.
120 * chronovu-la8 driver:
121 - Add support for newer LA8 versions with USB VID/PID 0403:8867.
122 * demo driver:
123 - Various bugfixes when setting time/sample limits.
124 * openbench-logic-sniffer driver:
125 - Don't try to scan all available serial ports for OLS devices. Instead,
126 the serial port to use now has to be specified by the user.
127 - Allow disabling RLE.
128 * udev rules file: Add many new entries for additional devices.
129 * New output formats:
130 - analog: Prints analog values and their unit (e.g. from scopes or DMMs).
131 * New input formats:
132 - vcd: Value Change Dump format
133 - wav: Waveform audio file format (for analog data)
134 * 'binary' input format: Add support for a 'samplerate' option.
135 * API related changes:
136 - There is generated Doxygen API documentation now.
137 - The header that frontends should include is: <libsigrok/libsigrok.h>.
138 There are other headers which are installed, but those are not meant to
139 be included directly by the frontends.
456dfd9f 140 - There were numerous API changes, additions and removals, too many to list
115f8293
UH
141 here. Please check the source code or Doxygen API documentation for the
142 current set of API functions.
143 * Serial port code:
144 - Various improvements and fixes related to multiple parameters such as
145 directions, baudrate, flow control, and others.
146 - Add support for more baudrates (e.g. very low ones such as 600/1200)
147 that are used in some devices.
148 - Add support for setting DTR/RTS.
456dfd9f 149 * gnuplot files: Add sample files for CWAV USBee DX (for 8/16 bit sampling).
115f8293
UH
150 * Documentation updates:
151 - Add a README.devices file which contains various notes for users of
152 libsigrok about device- and/or driver-specific issues.
153 - Update README, HACKING, and other documents.
154 - Updated build dependencies list.
155 - The following libs are needed in more recent versions now:
156 - glib (required): Now must be >= 2.32.0.
157 - libusb-1.0 (optional): Now must be >= 1.0.9.
158 - The following new libs were added as (optional) dependencies:
159 - libasound / alsa-lib (optional): >= 1.0
160 - check (optional, only needed for unit tests): >= 0.9.4
161 * Portability:
162 - Various compile fixes for Windows, FreeBSD/NetBSD/OpenBSD, and Mac OS X.
163 - Simplify/allow/fix cross-compilation of libsigrok.
164 - Various bugfixes for 32bit systems.
165 - Various endianness fixes.
166 * configure:
167 - Add a --disable-all-drivers option. This can be overridden by
168 additional --enable-<drivername> options to selectively enable only some.
169 - Improve autodetection of libraries, and only enable drivers for which
170 all required libraries were found.
171 * Add a test suite for libsigrok with a few unit tests (the list will grow).
0236ab68 172
5c4252cd 1730.1.1 (2012-05-30)
40cd2b54
UH
174------------------
175
02df29f0 176Note: This release does NOT change the libsigrok API.
40cd2b54
UH
177
178 * The 'saleae-logic' driver (which depends on the Saleae firmware), has
179 been replaced with the new 'fx2lafw' driver, which uses an open-source
180 firmware for Cypress FX2 chips which is also named 'fx2lafw'.
40cd2b54 181 Details: http://sigrok.org/wiki/Fx2lafw
40cd2b54 182 This new driver (+ firmware) currently supports the following devices:
9f05304e 183 - ARMFLY AX-Pro
40cd2b54
UH
184 - Braintechnology USB-LPS
185 - EE Electronics ESLA100
186 - EE Electronics ESLA201A
187 - Robomotic MiniLogic
188 - Robomotic BugLogic 3
189 - Saleae Logic
190 - USBee AX
191 - USBee SX
192 - All Cypress FX2 eval boards with stock Cypress VID/PID, including:
193 - Lcsoft Mini Board
194 - Braintechnology USB Interface V2.x
02df29f0
UH
195 Only acquisition with 8 probes is supported so far. Support for 16 probes
196 and support for analog signal acquisition (on devices which have these
197 capabilities) will be added later.
40cd2b54 198 * ASIX SIGMA driver:
40cd2b54
UH
199 - Add support for the ASIX SIGMA2. This requires the latest version of
200 the SIGMA/SIGMA2 firmware files.
40cd2b54 201 Details: http://sigrok.org/wiki/Firmware
40cd2b54 202 - Various bugfixes.
40cd2b54 203 * ZEROPLUS Logic Cube LAP-C (16032): Fix a segfault.
40cd2b54 204 * udev file: Add entries for Robomotic BugLogic 3, Velleman PCSU1000,
02df29f0
UH
205 Ideofy LA-08, ARMFLY AX-Pro, and Braintechnology USB Interface V2.x.
206 * The zlib dependency has been removed (no longer needed).
5c4252cd 207 * Fix compiling with "Homebrew" (Mac OS X).
5c4252cd
UH
208 * libsigrok now expects firmware files in $prefix/share/sigrok-firmware by
209 default (was $prefix/share/libsigrok/firmware before).
5c4252cd
UH
210 * Fix a Makefile.am bug which caused the generated ChangeLog files being
211 accidentally deleted upon 'make distclean'.
5c4252cd
UH
212 * ChronoVu LA8 input file format: Improve autodetection of the file format.
213 We now only accept files of the size 8388613 bytes (all LA8 files have
214 exactly this amount of bytes).
215
fefd54a0 2160.1.0 (2012-04-17)
c5d83a5a
UH
217------------------
218
219 * Initial release.
220