-The following drivers/devices require a serial port specification. Some of
-the drivers implement a default for the connection. Some of the drivers
-can auto-detect USB connected devices.
-
- - agilent-dmm
- - appa-55ii
- - atten-pps3xxx
- - brymen-dmm
- - cem-dt-885x
- - center-3xx (including all subdrivers)
- - colead-slm
- - conrad-digi-35-cpu
- - fluke-dmm
- - gmc-mh-1x-2x (including all subdrivers)
- - hameg-hmo
- - link-mso19
- - mic-985xx (including all subdrivers)
- - norma-dmm
- - openbench-logic-sniffer
- - rigol-ds (for RS232; not required for USBTMC or TCP)
- - serial-dmm (including all subdrivers)
- - serial-lcr (including all subdrivers)
- - teleinfo
- - tondaj-sl-814
- - uni-t-dmm (all -ser subdrivers)
- - uni-t-ut32x
-
-The following drivers/devices do not require a serial port specification:
-
- - asix-sigma
- - brymen-bm86x
- - chronovu-la
- - demo
- - fx2lafw
- - hantek-dso
- - ikalogic-scanalogic2
- - ikalogic-scanaplus
- - kecheng-kc-330b
- - lascar-el-usb
- - pipistrello-ols
- - rigol-ds (USBTMC or TCP)
- - saleae-logic16
- - sysclk-lwla
- - uni-t-dmm (all non -ser subdrivers)
- - yokogawa-dlm (USBTMC or TCP)
- - zeroplus-logic-cube
+Some of the drivers implement a default for the connection. Some of the
+drivers can auto-detect USB connected devices.