* EEVblog 121GW 19-bytes binary protocol parser.
*
- * @internal
- *
* Note that this protocol is different from other meters. We need not
* decode the LCD presentation (segments a-g and dot of seven segment
* displays). Neither need we decode a textual presentation consisting
static const struct mode_range_items mode_ranges_temp_sub = {
.range_count = 2,
.ranges = {
- [1] = { .desc = "sub 100.0C", .digits = 1, .factor = 1, },
+ [1] = { .desc = "100.0C", .digits = 1, .factor = 1, },
},
};
static const struct mode_range_items mode_ranges_freq_sub = {
.range_count = 4,
.ranges = {
- [1] = { .desc = "999.9Hz", .digits = 1, .factor = 1, },
- [2] = { .desc = "99.99Hz", .digits = 2, .factor = 2, },
- [3] = { .desc = "9.999kHz", .digits = 3, .factor = 3, },
+ [1] = { .desc = "999.9Hz", .digits = 1, .factor = 1, },
+ [2] = { .desc = "99.99Hz", .digits = 2, .factor = 2, },
+ [3] = { .desc = "9.999kHz", .digits = 3, .factor = 3, },
},
};
static const struct mode_range_items mode_ranges_batt_sub = {
.range_count = 2,
.ranges = {
- [1] = { .desc = "sub 10.0V", .digits = 1, .factor = 1, },
+ [1] = { .desc = "10.0V", .digits = 1, .factor = 1, },
},
};
static const struct mode_range_items mode_ranges_gain_sub = {
.range_count = 4,
.ranges = {
- [1] = { .desc = "dbm 5000.0dBm", .digits = 1, .factor = 1, },
- [2] = { .desc = "dbm 500.00dBm", .digits = 2, .factor = 2, },
- [3] = { .desc = "dbm 50.000dBm", .digits = 3, .factor = 3, },
+ [1] = { .desc = "5000.0dBm", .digits = 1, .factor = 1, },
+ [2] = { .desc = "500.00dBm", .digits = 2, .factor = 2, },
+ [3] = { .desc = "50.000dBm", .digits = 3, .factor = 3, },
},
};
static const struct mode_range_items mode_ranges_diode_sub = {
.range_count = 1,
.ranges = {
- [0] = { .desc = "diode 15.0V", .digits = 0, .factor = 0, },
+ [0] = { .desc = "15.0V", .digits = 0, .factor = 0, },
},
};
-/* TODO: Complete the list of ranges. Only tested with low voltages so far. */
static const struct mode_range_items mode_ranges_volts_sub = {
.range_count = 5,
.ranges = {
+ [3] = { .desc = "50.000V", .digits = 3, .factor = 3, },
[4] = { .desc = "5.0000V", .digits = 4, .factor = 4, },
},
};
-/* TODO: Complete the list of ranges. Only tested with low voltages so far. */
static const struct mode_range_items mode_ranges_mamps_sub = {
- .range_count = 3,
+ .range_count = 5,
.ranges = {
[2] = { .desc = "500.00mA", .digits = 5, .factor = 5, },
+ [3] = { .desc = "50.000mA", .digits = 6, .factor = 6, },
+ [4] = { .desc = "5.0000mA", .digits = 7, .factor = 7, },
+ },
+};
+
+static const struct mode_range_items mode_ranges_uamps_sub = {
+ .range_count = 5,
+ .ranges = {
+ [4] = { .desc = "5.0000mA", .digits = 7, .factor = 7, },
},
};
[MODE_AC_V] = &mode_ranges_volts_sub,
[MODE_DC_A] = &mode_ranges_mamps_sub,
[MODE_AC_A] = &mode_ranges_mamps_sub,
+ [MODE_DC_MA] = &mode_ranges_mamps_sub,
+ [MODE_AC_MA] = &mode_ranges_mamps_sub,
+ [MODE_DC_UA] = &mode_ranges_uamps_sub,
+ [MODE_AC_UA] = &mode_ranges_uamps_sub,
[MODE_FREQ] = &mode_ranges_freq_sub,
[MODE_DIODE] = &mode_ranges_diode_sub,
[MODE_SUB_TEMPC] = &mode_ranges_temp_sub,
* @return SR_OK upon success, SR_ERR upon failure. Upon errors, the
* 'analog' variable contents are undefined and should not be used.
*/
-SR_PRIV int sr_eev121gw_parse(const uint8_t *buf, float *floatval,
+static int sr_eev121gw_parse(const uint8_t *buf, float *floatval,
struct sr_datafeed_analog *analog, void *info)
{
struct eev121gw_info *info_local;
/*
* Get those fields which correspond to the secondary
* display. The value's mantissa has 16 bits. The sign
- * is separate is only applies to some of the modes.
+ * is separate and only applies to some of the modes.
* Scaling and precision also depend on the mode. The
* interpretation of the secondary display is different
* from the main display: The 'range' is not an index
}
is_k = FIELD_NB(raw_sub_range, SUB_RANGE_K);
- /*
- * TODO: Re-check the power mode display as more data becomes
- * available.
- *
- * The interpretation of the secondary display in power (VA)
- * modes is uncertain. The mode suggests A or uA units but the
- * value is supposed to be mA without a reliable condition
- * for us to check...
- *
- * f2 17 84 21 21 18 02 00 00 01 04 00 0b 00 00 0a 40 00 3f
- * f2 17 84 21 21 18 02 00 00 15 03 00 00 00 00 0a 40 00 27
- * DC VA DC V / DC A
- * 25.000VA dot 4 / dot 3
- *
- * f2 17 84 21 21 18 00 00 26 01 04 4c 57 00 00 0e 40 00 0f
- * f2 17 84 21 21 18 00 00 26 15 02 00 c7 00 00 0e 40 00 c1
- * 3.8mVA DC 1.9543V
- * 1.98mA (!) DC A + dot 2 -> milli(!) amps?
- *
- * f2 17 84 21 21 17 00 07 85 01 04 4c 5a 00 00 0e 40 00 a9
- * f2 17 84 21 21 17 00 07 85 13 04 26 7b 00 00 0e 40 00 f0
- * 1.925mVA DC 1.9546V
- * 0.9852mA
- *
- * f2 17 84 21 21 16 02 11 e0 01 04 26 39 00 02 0e 40 00 d2
- * f2 17 84 21 21 16 02 11 e0 11 04 12 44 00 02 0e 40 00 8b
- * 457.6uVA DC 0.9785V
- * 0.4676mA (!) DC uA + dot 4 -> milli(!) amps?
- */
-
switch (sub_mode) {
case MODE_DC_V:
info_local->is_voltage = TRUE;