* Output voltage.
* @arg type: double
- * @arg get: get output voltage
+ * @arg get: get measured output voltage
*/
SR_CONF_OUTPUT_VOLTAGE,
/**
- * Maximum output voltage.
+ * Maximum output voltage target.
* @arg type: double
- * @arg get: get maximum output voltage limit
- * @arg set: change output voltage limit
+ * @arg get: get output voltage target
+ * @arg set: change output voltage target
*/
- SR_CONF_OUTPUT_VOLTAGE_MAX,
+ SR_CONF_OUTPUT_VOLTAGE_TARGET,
/**
* Output current.
* @arg type: double
- * @arg get: get output current
+ * @arg get: get measured output current
*/
SR_CONF_OUTPUT_CURRENT,
/**
- * Maximum output current.
+ * Output current limit.
* @arg type: double
- * @arg get: get maximum output voltage limit
- * @arg set: change output voltage limit
+ * @arg get: get output current limit
+ * @arg set: change output current limit
*/
- SR_CONF_OUTPUT_CURRENT_MAX,
+ SR_CONF_OUTPUT_CURRENT_LIMIT,
/**
* Enabling/disabling output.